Digital evaluation of the accuracy of impression techniques and materials in angulated implants

被引:42
|
作者
Kurtulmus-Yilmaz, Sevcan [1 ]
Ozan, Oguz [1 ]
Ozcelik, Tuncer Burak [2 ]
Yagiz, Ayberk [3 ]
机构
[1] Near East Univ, Fac Dent, Dept Prosthodont, TR-10 Mersin, Turkey
[2] Baskent Univ, Fac Dent, Dept Prosthodont, Adana, Turkey
[3] Ay Tasarim Ltd, Ankara, Turkey
关键词
Implant angulation; Splinted direct technique; Indirect technique; Vinyl polysiloxane; Polyether; Vinyl polyether silicone; IN-VITRO; SUPPORTED SUPERSTRUCTURES; 3-DIMENSIONAL ACCURACY; SURGICAL GUIDES; CONNECTION; PROSTHESES; SYSTEM; FIT; HYDROPHILICITY; SILICONE;
D O I
10.1016/j.jdent.2014.10.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to investigate the accuracy of 2 different impression techniques and 3 different impression materials in models simulating parallel and angulated implants. Methods: Three master models simulating partial edentulous mandible with 2 implants at the sites of second premolars (parallel) and second molars with different angulations (parallel, 10 degrees or 20 degrees angulated) were fabricated. Two different impression techniques [ splinted direct (D), indirect (I)] and 3 different monophase impression materials [ polyether (PE), vinyl polysiloxane (VPS), vinyl polyether silicone (VPES)] were used for each master model and a total of 180 impressions were made (n = 10). Master model and casts were scanned by a modified laser scanner and data were transferred to VRMesh software. Master model and duplicate cast scans were digitally aligned observing the superposition of anatomic markers. Angular and coronal deviations between master and duplicated copings were calculated and data were statistically analyzed. Results: Mean angular and coronal deviations were in a range of 0.205-0.359 degrees and 22.5633.33 mu m, respectively. Statistical analysis revealed that the angulation of implant affected both coronal and angular deviations of the impression copings (P < 0.05). According to statistical analyses, for parallel implants, the accuracy of impression materials and techniques were ranging as VPS-D = PE-D > VPS-I = PE-I > VPES-D > VPES-I from most accurate to the least. For 10 degrees and 20 degrees angulated implants the most accurate material and technique was VPS-D whereas the least accurate combination was VPES-I (P < 0.05). Conclusion: Angulation, impression technique and material were found to be effective on the accuracy of implant impressions. Clinical significance: Clinicians may prefer VPS impression material and splinted direct technique for impressions of both parallel and up to 20 degrees angulated implants. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1551 / 1559
页数:9
相关论文
共 50 条
  • [1] Accuracy of two impression techniques with angulated implants
    Conrad, Heather J.
    Pesun, Igor J.
    DeLong, Ralph
    Hodges, James S.
    JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (06): : 349 - 356
  • [2] Accuracy of impressions with different impression materials in angulated implants
    Reddy, S.
    Prasad, K.
    Vakil, H.
    Jain, A.
    Chowdhary, R.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2013, 16 (03) : 279 - 284
  • [3] Accuracy of 3 different impression techniques for internal connection angulated implants
    Tsagkalidis, George
    Tortopidis, Dimitrios
    Mpikos, Pavlos
    Kaisarlis, George
    Koidis, Petros
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (04): : 517 - 523
  • [4] The Accuracy of Casts Obtained Using Different Impression Techniques and Impression Materials in Combined Parallel and Angulated Implants: An In Vitro Study
    Menaga, V
    Chirom, Babina
    Gunadhar, Kangjam
    Priyadarshini, Shamurailatpam
    Nongthombam, Rajesh S.
    Manikandan, P.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
  • [5] Comparison of the accuracy of different impression procedures in case of multiple and angulated implants Accuracy of impressions in multiple and angulated implants
    Richi, M. Wafa
    Kurtulmus-Yilmaz, Sevcan
    Ozan, Oguz
    HEAD & FACE MEDICINE, 2020, 16 (01)
  • [6] Evaluation of the accuracy of different transfer impression techniques for multiple implants
    Brigolini de Faria, Julio Cesar
    Silva-Concilio, Lais Regiane
    Claro Neves, Ana Christina
    Miranda, Milton Edson
    Teixeira, Marcelo Lucchesi
    BRAZILIAN ORAL RESEARCH, 2011, 25 (02) : 163 - 167
  • [7] Comparison of the accuracy of different impression procedures in case of multiple and angulated implantsAccuracy of impressions in multiple and angulated implants
    M. Wafa Richi
    Sevcan Kurtulmus-Yilmaz
    Oguz Ozan
    Head & Face Medicine, 16
  • [8] Effects of impression levels and trays on the accuracy of impressions taken from angulated implants
    Geramipanah, Farideh
    Sahebi, Majid
    Davari, Maryam
    Hajimahmoudi, Mohammadreza
    Rakhshan, Vahid
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (09) : 1098 - 1105
  • [9] Accuracy of 2 impression techniques for ITI implants
    Akça, K
    Çehreli, MC
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2004, 19 (04) : 517 - 523
  • [10] Evaluation of the Accuracy of Conventional and Digital Impression Techniques for Implant Restorations
    Moura, Renata Vasconcellos
    Kojima, Alberto Noriyuki
    Coury Saraceni, Cintia Helena
    Bassolli, Lucas
    Balducci, Ivan
    Ozcan, Mutlu
    Melo Mesquita, Alfredo Mikail
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E530 - E535