Accuracy of 2 impression techniques for ITI implants

被引:1
|
作者
Akça, K [1 ]
Çehreli, MC [1 ]
机构
[1] Hacettepe Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
关键词
dental implants; impression materials; impression techniques;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to compare the accuracy of casts produced by 2 impression techniques and elastomeric impression materials commonly used for the fabrication of implant-supported fixed prostheses. Materials and Methods: A master model with 4 synOcta ITI implants placed unilaterally in place of the mandibular right central incisor, canine, first premolar, and first molar was constructed. Implant-level impressions were made by direct and indirect techniques. In the direct technique, synOcta impression caps with integral guide screws were used to transfer the implants using a custom-made acrylic resin tray and a polyether impression material (the PE direct technique). In the indirect technique, synOcta plastic positioning cylinders with impression caps were used to transfer the implants with either a custom-made acrylic resin tray and polyether impression material (the PE indirect technique) or with a stock tray with a vinylpolysiloxane impression material (the VPS indirect technique). After impression making, all casts (n = 21) were poured in type IV dental stone. Linear changes in -x or -y direction and numeric and descriptive angular changes between the implants were quantified using a coordinate measuring machine. Results: Seven of 12 distance measurements (6 for -x direction, 6 for -y direction) showed differences between groups (P < .05). Of these, 5 were associated with the PE direct versus PE indirect and PE indirect versus VPS indirect, and 3 were associated with PE direct versus VPS indirect. Two implants also showed angular changes but only for the PE indirect technique versus the VPS indirect technique (P < .05). Conclusion: The snap-on VPS indirect impression technique using a stock tray, which has the advantages of being clinically convenient and eliminating repositioning after removal of the impression, resulted in dimensional accuracy similar to that achieved with the PE direct technique.
引用
收藏
页码:517 / 523
页数:7
相关论文
共 50 条
  • [1] Accuracy of two impression techniques with angulated implants
    Conrad, Heather J.
    Pesun, Igor J.
    DeLong, Ralph
    Hodges, James S.
    JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (06): : 349 - 356
  • [2] Comparison of the Accuracy of Different Transfer Impression Techniques for Osseointegrated Implants
    Zen, Bruno Massucato
    Soares, Eveline Freitas
    Rodrigues, Mariana Agustinho
    Luthi, Leonardo Flores
    Consani, Rafael Leonardo X.
    Mesquita, Marcelo Ferraz
    Pessanha Henriques, Guilherme Elias
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (06) : 662 - 667
  • [3] Accuracy of Different Impression Techniques for Internal-Connection Implants
    Lee, Yun-Jung
    Heo, Seong-Joo
    Koak, Jai-Young
    Kim, Seong-Kyun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 823 - 830
  • [4] Evaluation of the accuracy of different transfer impression techniques for multiple implants
    Brigolini de Faria, Julio Cesar
    Silva-Concilio, Lais Regiane
    Claro Neves, Ana Christina
    Miranda, Milton Edson
    Teixeira, Marcelo Lucchesi
    BRAZILIAN ORAL RESEARCH, 2011, 25 (02) : 163 - 167
  • [5] Digital evaluation of the accuracy of impression techniques and materials in angulated implants
    Kurtulmus-Yilmaz, Sevcan
    Ozan, Oguz
    Ozcelik, Tuncer Burak
    Yagiz, Ayberk
    JOURNAL OF DENTISTRY, 2014, 42 (12) : 1551 - 1559
  • [6] COMPARISON OF THE ACCURACY OF INTRAORAL SCANNING AND CONVENTIONAL IMPRESSION TECHNIQUES ON IMPLANTS: A REVIEW
    Arcuri, L.
    Lorenzi, C.
    Vanni, A.
    Bianchi, N.
    Dolci, A.
    Arcuri, C.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2020, 34 : 89 - 97
  • [7] Accuracy of Impression Techniques for Dental Implants Placed in Five Different Orientations
    Kim, Hyo-Seon
    Lee, Jae-Hyun
    Lee, Su Young
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (05) : 997 - 1002
  • [8] Accuracy of 3 different impression techniques for internal connection angulated implants
    Tsagkalidis, George
    Tortopidis, Dimitrios
    Mpikos, Pavlos
    Kaisarlis, George
    Koidis, Petros
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (04): : 517 - 523
  • [9] A comparative analysis of the accuracy of different direct impression techniques for multiple implants
    Ongul, D.
    Gokcen-Rohlig, B.
    Sermet, B.
    Keskin, H.
    AUSTRALIAN DENTAL JOURNAL, 2012, 57 (02) : 184 - 189
  • [10] A laboratory investigation of the accuracy of two impression techniques for single-tooth implants
    Daoudi, MF
    Setchell, DJ
    Searson, LJ
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2001, 14 (02) : 152 - 158