Comparison of the accuracy of different impression procedures in case of multiple and angulated implants Accuracy of impressions in multiple and angulated implants

被引:18
|
作者
Richi, M. Wafa [1 ]
Kurtulmus-Yilmaz, Sevcan [1 ]
Ozan, Oguz [1 ]
机构
[1] Near East Univ, Dept Prosthodont, Fac Dent, Mersin10, Ankara, Turkey
关键词
ARCH;
D O I
10.1186/s13005-020-00225-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: There is no consensus in the literature regarding the impression procedures in the presence of multiple and angulated implants. Methods: Three maxillary master models with 6 implants bilaterally positioned in anterior, premolar and molar regions were fabricated. In model 1, all implants were placed in parallel; in models 2 and 3, anterior implants were buccally inclined and posterior implants were distally inclined in 10- and 20-degrees, respectively. Three different impression copings (hexed, non-hex, multi-unit) and two different impression techniques (splinting and non-splinting) were tested. A total of 180 impressions (n = 10 per group) were made using mono-phase vinyl polysiloxane. Master models and duplicate casts were scanned by a 5-axis laboratory scanner and data were transferred to a software program for the alignment of master and duplicate copings. Coronal and angular deviations were calculated, and data were statistically analyzed. Results: For angulated models, the lowest deviation values were detected at the splinted non-hex coping group (P < 0.05). Conclusions: Implant angulation, impression coping type, and splinting the impression copings had significant effects on the accuracy of impressions.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Comparison of the accuracy of different impression procedures in case of multiple and angulated implantsAccuracy of impressions in multiple and angulated implants
    M. Wafa Richi
    Sevcan Kurtulmus-Yilmaz
    Oguz Ozan
    Head & Face Medicine, 16
  • [2] Accuracy of impressions with different impression materials in angulated implants
    Reddy, S.
    Prasad, K.
    Vakil, H.
    Jain, A.
    Chowdhary, R.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2013, 16 (03) : 279 - 284
  • [3] Accuracy of two impression techniques with angulated implants
    Conrad, Heather J.
    Pesun, Igor J.
    DeLong, Ralph
    Hodges, James S.
    JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (06): : 349 - 356
  • [4] Effects of impression levels and trays on the accuracy of impressions taken from angulated implants
    Geramipanah, Farideh
    Sahebi, Majid
    Davari, Maryam
    Hajimahmoudi, Mohammadreza
    Rakhshan, Vahid
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (09) : 1098 - 1105
  • [5] Accuracy of 3 different impression techniques for internal connection angulated implants
    Tsagkalidis, George
    Tortopidis, Dimitrios
    Mpikos, Pavlos
    Kaisarlis, George
    Koidis, Petros
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (04): : 517 - 523
  • [6] Digital evaluation of the accuracy of impression techniques and materials in angulated implants
    Kurtulmus-Yilmaz, Sevcan
    Ozan, Oguz
    Ozcelik, Tuncer Burak
    Yagiz, Ayberk
    JOURNAL OF DENTISTRY, 2014, 42 (12) : 1551 - 1559
  • [7] The Accuracy of Casts Obtained Using Different Impression Techniques and Impression Materials in Combined Parallel and Angulated Implants: An In Vitro Study
    Menaga, V
    Chirom, Babina
    Gunadhar, Kangjam
    Priyadarshini, Shamurailatpam
    Nongthombam, Rajesh S.
    Manikandan, P.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
  • [8] Evaluation of the accuracy of different transfer impression techniques for multiple implants
    Brigolini de Faria, Julio Cesar
    Silva-Concilio, Lais Regiane
    Claro Neves, Ana Christina
    Miranda, Milton Edson
    Teixeira, Marcelo Lucchesi
    BRAZILIAN ORAL RESEARCH, 2011, 25 (02) : 163 - 167
  • [9] A comparative analysis of the accuracy of different direct impression techniques for multiple implants
    Ongul, D.
    Gokcen-Rohlig, B.
    Sermet, B.
    Keskin, H.
    AUSTRALIAN DENTAL JOURNAL, 2012, 57 (02) : 184 - 189
  • [10] Influence of Different Factors on the Accuracy of Digital Impressions of Multiple Implants: An In Vitro Study
    Zhang, Yi-Jie
    Qiao, Shi-Chong
    Qian, Shu-Jiao
    Zhang, Chu-Nan
    Shi, Jun-Yu
    Lai, Hong-Chang
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (03) : 442 - 449