Comparison of the accuracy of different impression procedures in case of multiple and angulated implants Accuracy of impressions in multiple and angulated implants

被引:18
|
作者
Richi, M. Wafa [1 ]
Kurtulmus-Yilmaz, Sevcan [1 ]
Ozan, Oguz [1 ]
机构
[1] Near East Univ, Dept Prosthodont, Fac Dent, Mersin10, Ankara, Turkey
关键词
ARCH;
D O I
10.1186/s13005-020-00225-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: There is no consensus in the literature regarding the impression procedures in the presence of multiple and angulated implants. Methods: Three maxillary master models with 6 implants bilaterally positioned in anterior, premolar and molar regions were fabricated. In model 1, all implants were placed in parallel; in models 2 and 3, anterior implants were buccally inclined and posterior implants were distally inclined in 10- and 20-degrees, respectively. Three different impression copings (hexed, non-hex, multi-unit) and two different impression techniques (splinting and non-splinting) were tested. A total of 180 impressions (n = 10 per group) were made using mono-phase vinyl polysiloxane. Master models and duplicate casts were scanned by a 5-axis laboratory scanner and data were transferred to a software program for the alignment of master and duplicate copings. Coronal and angular deviations were calculated, and data were statistically analyzed. Results: For angulated models, the lowest deviation values were detected at the splinted non-hex coping group (P < 0.05). Conclusions: Implant angulation, impression coping type, and splinting the impression copings had significant effects on the accuracy of impressions.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Accuracy of Impression Techniques for Dental Implants Placed in Five Different Orientations
    Kim, Hyo-Seon
    Lee, Jae-Hyun
    Lee, Su Young
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (05) : 997 - 1002
  • [22] COMPARISON OF THE ACCURACY OF INTRAORAL SCANNING AND CONVENTIONAL IMPRESSION TECHNIQUES ON IMPLANTS: A REVIEW
    Arcuri, L.
    Lorenzi, C.
    Vanni, A.
    Bianchi, N.
    Dolci, A.
    Arcuri, C.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2020, 34 : 89 - 97
  • [23] In vitro scanning accuracy using different aids for multiple implants in the edentulous arch
    Kernen, Florian R.
    Recca, Mario
    Vach, Kirstin
    Nahles, Susanne
    Nelson, Katja
    Fluegge, Tabea, V
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (10) : 1010 - 1020
  • [24] The dimensional accuracy of the splinted impression technique and the unsplinted impression technique for multiple Bone-Lock(R) implants.
    Burawi, G
    Houston, F
    Claffey, N
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 1155 - 1155
  • [25] Dimensional accuracy of vinyl polyetherand polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants
    Rajendran, Rohini
    Chander, N. Gopi
    Anitha, Kuttae Vishwanathan
    Muthukumar, Balasubramanian
    EUROPEAN ORAL RESEARCH, 2021, 55 (02) : 54 - 59
  • [26] Effect of the Association Between the Tray and Impression Techniques on Angulated Implants Using the All-on-Four System
    de Avila, Erica Dorigatti
    Castanharo, Sabrina Maria
    Casalle, Nicole
    Vasconcelos, Juliano Alencar
    Mollo, Francisco de Assis, Jr.
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 : 382 - 385
  • [27] Could various angulated implant depths affect the positional accuracy of digital impressions? An in vitro study
    Taghva, Masumeh
    Mosaddad, Seyed Ali
    Ansarifard, Elham
    Sadeghi, Mohsen
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023,
  • [28] Effect of Splinting on Dimensional Accuracy of Impressions Made of Implants with Different Subgingival Alignments
    Beyabanaki, Elaheh
    Shamshiri, Ahmed Reza
    Alikhasi, Marzieh
    Monzavi, Abbas
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (01): : 48 - 55
  • [29] Accuracy of digital impression in dental implants: A literature review
    Kulivand, Sudabe
    Moslemion, Maryam
    INTERNATIONAL JOURNAL OF ADVANCED BIOTECHNOLOGY AND RESEARCH, 2016, 7 (04): : 2093 - 2100
  • [30] Prosthetic transfer impression accuracy evaluation for osseointegrated implants
    Assuncao, Wirley Goncalves
    Tabata, Lucas Fernando
    Cardoso, Alessandra
    Rocha, Eduardo Passos
    Gomes, Erica Alves
    IMPLANT DENTISTRY, 2008, 17 (03) : 248 - 252