Effect of fiber angles on normal- and high-strength concrete-filled fiber-reinforced polymer tubes under monotonic axial compression

被引:28
|
作者
Zhang, Bing [1 ]
Hu, Xia-Min [1 ]
Zhao, Qing [1 ]
Huang, Tao [1 ]
Zhang, Ning-Yuan [1 ]
Zhang, Qian-Biao [1 ]
机构
[1] Nanjing Tech Univ, Coll Civil Engn, Nanjing 211826, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
axial compression test; concrete-filled FRP tubes; fiber angles; stress-strain curve; FRP-CONFINED CONCRETE; STRESS-STRAIN BEHAVIOR; MODEL; COLUMNS; ORIENTATION;
D O I
10.1177/1369433219886082
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete-filled fiber-reinforced polymer tubes are a novel form of composite columns, which are particularly attractive for structural members in harsh environments and seismic regions due to their corrosion resistance and ductile behavior. Over the past two decades, many studies have been conducted on concrete-filled fiber-reinforced polymer tubes under axial compression, and many stress-strain models have been proposed. However, existing studies mainly focused on concrete-filled fiber-reinforced polymer tubes with only hoop fibers. In order to investigate the effect of fiber angles (i.e. the fiber angle between the fiber orientation and the longitudinal axis of fiber-reinforced polymer tube), this study conducted axial compression tests of 42 concrete-filled fiber-reinforced polymer tubes with +/- 80 degrees, +/- 60 degrees, or +/- 45 degrees fiber angles. These concrete-filled fiber-reinforced polymer tubes were constructed using normal-strength concrete or high-strength concrete. Fiber-reinforced polymer tube thickness was also investigated as an important parameter. In order to clarify the effect of fiber angles on the properties of fiber-reinforced polymer tubes, axial compression tests on 15 short fiber-reinforced polymer tubes and tensile split-disk tests on 75 fiber-reinforced polymer rings were conducted. Experimental results indicate that fiber angles had significant influences on the hoop properties of fiber-reinforced polymer tube; the confinement effect of fiber-reinforced polymer tube and the peak stress of the confined concrete decreased with the decrease of the absolute value of fiber angles, while the ultimate strain of the confined concrete increased with the decrease of the absolute value of fiber angles. Two existing stress-strain models, which were developed mainly on test results of concrete confined by fiber-reinforced polymer tubes with only hoop fibers, are capable of providing reasonably accurate predictions for concrete-filled fiber-reinforced polymer tubes with +/- 80 degrees and +/- 60 degrees fiber angles, but it underestimates the ultimate axial strain of concrete-filled fiber-reinforced polymer tubes with +/- 45 degrees fiber angles.
引用
收藏
页码:924 / 940
页数:17
相关论文
共 50 条
  • [1] Flexural Behavior of Post-Tensioned Normal- and High-Strength Concrete-Filled Fiber-Reinforced Polymer Tubes
    Ahmed, Asmaa Abdeldaim
    Hassan, Mohamed
    Masmoudi, Radhouane
    ACI STRUCTURAL JOURNAL, 2021, 118 (02) : 73 - 88
  • [2] Experimental investigation of the behavior of concrete-filled high-strength glass fiber-reinforced polymer tubes under static and cyclic axial compression
    Aslani, Farhad
    Deghani, Ayoub
    Gunawardena, Yasoja
    STRUCTURAL CONCRETE, 2020, 21 (04) : 1497 - 1522
  • [3] Behavior of steel fiber-reinforced high-strength concrete-filled FRP tube columns under axial compression
    Xie, Tianyu
    Ozbakkaloglu, Togay
    ENGINEERING STRUCTURES, 2015, 90 : 158 - 171
  • [4] Fatigue behavior of concrete-filled fiber-reinforced polymer tubes
    Ahmad, Iftekhar
    Zhu, Zhenyu
    Mirmiran, Amir
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2008, 12 (04) : 478 - 487
  • [5] Fatigue Modeling of Concrete-Filled Fiber-Reinforced Polymer Tubes
    Zhu, Zhenyu
    Ahmad, Iftekhar
    Mirmiran, Amir
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2009, 13 (06) : 582 - 590
  • [6] Experimental Study of Normal- and High-Strength Concrete Confined with Fiber-Reinforced Polymers
    Cui, C.
    Sheikh, S. A.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2010, 14 (05) : 553 - 561
  • [7] Bond performance of fiber reinforced polymer bars in normal- and high-strength concrete
    El-Nemr, Amr
    Ahmed, Ehab A.
    Barris, Cristina
    Joyklad, Panuwat
    Hussain, Qudeer
    Benmokrane, Brahim
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 393
  • [8] Influence of fiber orientation and shell thickness on the axial compressive behavior of concrete-filled fiber-reinforced polymer tubes
    Hain, Alexandra
    Motaref, Sarira
    Zaghi, Arash E.
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 220 : 353 - 363
  • [9] Flexural Behavior of concrete-filled fiber-reinforced polymer circular tubes
    Fam, AZ
    Rizkalla, SH
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2002, 6 (02) : 123 - 132
  • [10] Experimental study on concrete-filled steel tube columns with inner distributed seawater and sea sand concrete-filled fiber-reinforced polymer tubes under axial compression
    Miao, Kunting
    Wei, Yang
    Dong, Fenghui
    Zheng, Kaiqi
    Wang, Jiaqing
    COMPOSITE STRUCTURES, 2023, 320