Effect of fiber angles on normal- and high-strength concrete-filled fiber-reinforced polymer tubes under monotonic axial compression

被引:28
|
作者
Zhang, Bing [1 ]
Hu, Xia-Min [1 ]
Zhao, Qing [1 ]
Huang, Tao [1 ]
Zhang, Ning-Yuan [1 ]
Zhang, Qian-Biao [1 ]
机构
[1] Nanjing Tech Univ, Coll Civil Engn, Nanjing 211826, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
axial compression test; concrete-filled FRP tubes; fiber angles; stress-strain curve; FRP-CONFINED CONCRETE; STRESS-STRAIN BEHAVIOR; MODEL; COLUMNS; ORIENTATION;
D O I
10.1177/1369433219886082
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete-filled fiber-reinforced polymer tubes are a novel form of composite columns, which are particularly attractive for structural members in harsh environments and seismic regions due to their corrosion resistance and ductile behavior. Over the past two decades, many studies have been conducted on concrete-filled fiber-reinforced polymer tubes under axial compression, and many stress-strain models have been proposed. However, existing studies mainly focused on concrete-filled fiber-reinforced polymer tubes with only hoop fibers. In order to investigate the effect of fiber angles (i.e. the fiber angle between the fiber orientation and the longitudinal axis of fiber-reinforced polymer tube), this study conducted axial compression tests of 42 concrete-filled fiber-reinforced polymer tubes with +/- 80 degrees, +/- 60 degrees, or +/- 45 degrees fiber angles. These concrete-filled fiber-reinforced polymer tubes were constructed using normal-strength concrete or high-strength concrete. Fiber-reinforced polymer tube thickness was also investigated as an important parameter. In order to clarify the effect of fiber angles on the properties of fiber-reinforced polymer tubes, axial compression tests on 15 short fiber-reinforced polymer tubes and tensile split-disk tests on 75 fiber-reinforced polymer rings were conducted. Experimental results indicate that fiber angles had significant influences on the hoop properties of fiber-reinforced polymer tube; the confinement effect of fiber-reinforced polymer tube and the peak stress of the confined concrete decreased with the decrease of the absolute value of fiber angles, while the ultimate strain of the confined concrete increased with the decrease of the absolute value of fiber angles. Two existing stress-strain models, which were developed mainly on test results of concrete confined by fiber-reinforced polymer tubes with only hoop fibers, are capable of providing reasonably accurate predictions for concrete-filled fiber-reinforced polymer tubes with +/- 80 degrees and +/- 60 degrees fiber angles, but it underestimates the ultimate axial strain of concrete-filled fiber-reinforced polymer tubes with +/- 45 degrees fiber angles.
引用
收藏
页码:924 / 940
页数:17
相关论文
共 50 条
  • [31] Behavior of short and deep beams made of concrete-filled fiber-reinforced polymer tubes
    Ahmad, Iftekhar
    Zhu, Zhenyu
    Mirmiran, Amir
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2008, 12 (01) : 102 - 110
  • [32] Behaviour of high-strength spirally reinforced square concrete-filled steel tubes under eccentric compression
    Li, Wei-Jie
    Li, Wei
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 228
  • [33] Behavior of Steel Fiber-Reinforced High-Strength Concrete Columns under Uniaxial Compression
    Paultre, P.
    Eid, R.
    Langlois, Y.
    Levesque, Y.
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2010, 136 (10): : 1225 - 1235
  • [34] Effect of Column Parameters on Cyclic Behavior of Ultra-High-Performance Concrete-Filled Fiber-Reinforced Polymer Tubes
    Zohrevand, Pedram
    Mirmiran, Amir
    ACI STRUCTURAL JOURNAL, 2013, 110 (05) : 823 - 831
  • [35] Size effect in normal- and high-strength amorphous metallic and steel fiber reinforced concrete beams
    Yoo, Doo-Yeol
    Banthia, Nemkumar
    Yang, Jun-Mo
    Yoon, Young-Soo
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 121 : 676 - 685
  • [36] Hybrid fiber reinforced concrete-filled square stub columns under axial compression
    Guler, Soner
    Yavuz, Demet
    Aydin, Muhammet
    ENGINEERING STRUCTURES, 2019, 198
  • [37] Structural behaviors of steel fiber-reinforced concrete-filled geotextile tube stub columns under axial compression
    Li, Tingchun
    Ran, Jinlin
    Chen, Dianhao
    Du, Yiteng
    Zhu, Qingwen
    Zhang, Hao
    Li, Weiteng
    STRUCTURES, 2022, 40 : 434 - 447
  • [38] Stress-strain behavior of polyethylene terephthalate fiber-reinforced polymer -confined normal-, high- and ultra high-strength concrete
    Zeng, Jun-Jie
    Ye, Yu-Yi
    Gao, Wan-Yang
    Smith, Scott T.
    Guo, Yong-Chang
    JOURNAL OF BUILDING ENGINEERING, 2020, 30
  • [39] Performance of recycled aggregate concrete-filled high-strength steel tubes under axial compression, tension and torsion
    Zhao, Hua-Yang
    Han, Lin-Hai
    Hou, Chao
    Lyu, Wan-Qing
    THIN-WALLED STRUCTURES, 2023, 184
  • [40] Mechanical properties of normal to high-strength steel fiber-reinforced concrete
    Khaloo, AR
    Kim, N
    CEMENT CONCRETE AND AGGREGATES, 1996, 18 (02): : 92 - 97