Effect of fiber angles on normal- and high-strength concrete-filled fiber-reinforced polymer tubes under monotonic axial compression

被引:28
|
作者
Zhang, Bing [1 ]
Hu, Xia-Min [1 ]
Zhao, Qing [1 ]
Huang, Tao [1 ]
Zhang, Ning-Yuan [1 ]
Zhang, Qian-Biao [1 ]
机构
[1] Nanjing Tech Univ, Coll Civil Engn, Nanjing 211826, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
axial compression test; concrete-filled FRP tubes; fiber angles; stress-strain curve; FRP-CONFINED CONCRETE; STRESS-STRAIN BEHAVIOR; MODEL; COLUMNS; ORIENTATION;
D O I
10.1177/1369433219886082
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete-filled fiber-reinforced polymer tubes are a novel form of composite columns, which are particularly attractive for structural members in harsh environments and seismic regions due to their corrosion resistance and ductile behavior. Over the past two decades, many studies have been conducted on concrete-filled fiber-reinforced polymer tubes under axial compression, and many stress-strain models have been proposed. However, existing studies mainly focused on concrete-filled fiber-reinforced polymer tubes with only hoop fibers. In order to investigate the effect of fiber angles (i.e. the fiber angle between the fiber orientation and the longitudinal axis of fiber-reinforced polymer tube), this study conducted axial compression tests of 42 concrete-filled fiber-reinforced polymer tubes with +/- 80 degrees, +/- 60 degrees, or +/- 45 degrees fiber angles. These concrete-filled fiber-reinforced polymer tubes were constructed using normal-strength concrete or high-strength concrete. Fiber-reinforced polymer tube thickness was also investigated as an important parameter. In order to clarify the effect of fiber angles on the properties of fiber-reinforced polymer tubes, axial compression tests on 15 short fiber-reinforced polymer tubes and tensile split-disk tests on 75 fiber-reinforced polymer rings were conducted. Experimental results indicate that fiber angles had significant influences on the hoop properties of fiber-reinforced polymer tube; the confinement effect of fiber-reinforced polymer tube and the peak stress of the confined concrete decreased with the decrease of the absolute value of fiber angles, while the ultimate strain of the confined concrete increased with the decrease of the absolute value of fiber angles. Two existing stress-strain models, which were developed mainly on test results of concrete confined by fiber-reinforced polymer tubes with only hoop fibers, are capable of providing reasonably accurate predictions for concrete-filled fiber-reinforced polymer tubes with +/- 80 degrees and +/- 60 degrees fiber angles, but it underestimates the ultimate axial strain of concrete-filled fiber-reinforced polymer tubes with +/- 45 degrees fiber angles.
引用
收藏
页码:924 / 940
页数:17
相关论文
共 50 条
  • [21] Influence of Slenderness on Behavior of High-Strength Concrete-Filled FRP Tubes under Axial Compression
    Vincent, Thomas
    Ozbakkloglu, Togay
    ADVANCES IN CIVIL AND STRUCTURAL ENGINEERING III, PTS 1-4, 2014, 501-504 : 963 - 968
  • [22] Fiber-reinforced concrete incorporating locally available natural fibers in normal- and high-strength concrete and a performance analysis with steel fiber-reinforced composite concrete
    Islam, Syed Mazharul
    Hussain, Raja Rizwan
    Morshed, Md. Abu Zakir
    JOURNAL OF COMPOSITE MATERIALS, 2012, 46 (01) : 111 - 122
  • [23] Performance of circular concrete-filled fiber-reinforced polymer-steel composite tube columns under axial compression
    Wei, Yang
    Wu, Gang
    Li, Guofen
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2014, 33 (20) : 1911 - 1928
  • [24] Axial behavior of concrete-filled carbon fiber-reinforced polymer composite columns
    Kim, Heecheul
    Lee, Kyoung Hun
    Lee, Young Hak
    Lee, Junbok
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2012, 21 (03): : 178 - 193
  • [25] High strength expansive concrete-encased-steel filled carbon fiber reinforced polymer tubes under axial monotonic and cyclic load
    Cao, Qi
    Lv, Xianrui
    Li, Xiaojun
    Zhou, Changjun
    Song, Shide
    JOURNAL OF COMPOSITE MATERIALS, 2020, 54 (29) : 4557 - 4573
  • [26] Seismic behavior of high-strength concrete columns confined by fiber-reinforced polymer tubes
    Ozbakkaloglu, Togay
    Saatcioglu, Murat
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2006, 10 (06) : 538 - 549
  • [27] Polymer concrete-filled steel tubes under axial compression
    Oyawa, WO
    Sugiura, K
    Watanabe, E
    CONSTRUCTION AND BUILDING MATERIALS, 2001, 15 (04) : 187 - 197
  • [28] Hysteresis performance of steel fiber-reinforced high-strength concrete-filled steel tube columns
    Huang, Yue
    Zhao, Pengtuan
    Lu, Yiyan
    Liu, Zhenzhen
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 219
  • [29] Experimental and analytical modeling of concrete-filled fiber-reinforced polymer tubes subjected to combined bending and axial loads
    Fam, A
    Flisak, B
    Rizkalla, S
    ACI STRUCTURAL JOURNAL, 2003, 100 (04) : 499 - 509
  • [30] Behavior of square and rectangular ultra high-strength concrete-filled FRP tubes under axial compression
    Ozbakkaloglu, Togay
    COMPOSITES PART B-ENGINEERING, 2013, 54 : 97 - 111