Bond performance of fiber reinforced polymer bars in normal- and high-strength concrete

被引:10
|
作者
El-Nemr, Amr [1 ,9 ]
Ahmed, Ehab A. [2 ,3 ]
Barris, Cristina [4 ]
Joyklad, Panuwat [5 ]
Hussain, Qudeer [6 ]
Benmokrane, Brahim [7 ,8 ]
机构
[1] German Univ Cairo GUC, Dept Civil Engn Dept, New Cairo, Egypt
[2] Toronto Metropolitan Univ, Toronto, ON, Canada
[3] Menoufia Univ, Dept Civil Engn, Shibin Al Kawm, Menofia Governo, Egypt
[4] Univ Girona, Dept Mech Engn & Ind Construct, Girona, Spain
[5] Srinakharinwirot Univ, Fac Engn, Dept Civil & Environm Engn, Bangkok, Thailand
[6] Chulalongkorn Univ, Ctr Excellence Earthquake Engn & Vibrat, Dept Civil Engn, Bangkok, Thailand
[7] Univ Sherbrooke, Civil Engn & NSERC Res Chair FRP Reinforcement Con, Sherbrooke, PQ J1K 2R1, Canada
[8] Univ Sherbrooke, Tier Canada Res Chair Adv Compos Mat Civil Struct, Dept Civil Engn, Sherbrooke, PQ J1K 2R1, Canada
[9] Sherbrooke Univ, Dept Civil & Bldg Engn, Sherbrooke, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Concrete; Fiber-reinforced polymer (FRP); FRP bar; Bond strength; Bond stress-slip relationship; Analytical modelling; Design codes; BEHAVIOR; REBARS;
D O I
10.1016/j.conbuildmat.2023.131957
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The structural performance of reinforced concrete (RC) members depends on the bond between the reinforcing bars and surrounding concrete. Unlike steel bars, fiber-reinforced polymer (FRP) bars are manufactured with different fiber types (glass, basalt, carbon, and aramid) and have different mechanical properties and surface configurations (sand-coated, deformed, grooved, sand-coated over helical wrapping). These differences impact the bond performance between the FRP bars and concrete. This paper investigates the bond performance of new generation and different FRP bars embedded in concrete. A total of 87 pullout specimens were constructed and tested until failure. The test results are presented and discussed. The test parameters include (i) fiber type (glass or carbon), (ii) surface configuration (sand-coated, deformed, or grooved), (iii) No. 4 to No. 8 (13 to 25.4 mm diameter) bar diameters), and (iv) concrete strength (normal- or high-strength concrete: NSC or HSC). Specimens with deformed 10 M or 15 M steel bars were also fabricated as controls and tested for comparison. The embedment length and block dimensions were also considered to ensure pullout-failure mode. The test results reveal that increasing the bar diameter generally reduced the bond strength of the FRP bars, while the bar diameter had insignificant impact on the steel bars. There was a positive relationship between the concrete compressive strength and the bond strength gained. The anticipated failure modes with the high concrete strength were at the fiber resin interface due to the high confinement generated by high-strength concrete. With the lower strength, failure usually occurred at the resin-concrete interface. In addition, the test results were used to assess different analytical models for bond stress-slip relationships.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Flexural Behavior and Serviceability of Normal- and High-Strength Concrete Beams Reinforced with Glass Fiber-Reinforced Polymer Bars
    El-Nemr, Amr
    Ahmed, Ehab A.
    Benmokrane, Brahim
    [J]. ACI STRUCTURAL JOURNAL, 2013, 110 (06) : 1077 - 1087
  • [2] Interfacial bond strength of glass fiber reinforced polymer bars in high-strength concrete
    Lee, J. -Y.
    Kim, T. -Y.
    Kim, T. J.
    Yi, C. -K.
    Park, J. -S.
    You, Y. -C.
    Park, Y. -H.
    [J]. COMPOSITES PART B-ENGINEERING, 2008, 39 (02) : 258 - 270
  • [3] Bond Strength of BFRP Bars to Basalt Fiber Reinforced High-Strength Concrete
    Bi, Qiaowei
    Wang, Hui
    [J]. ADVANCES IN FRP COMPOSITES IN CIVIL ENGINEERING, 2010, : 576 - +
  • [4] Effect of Fiber-Reinforced Polymer Confinement on Bond Strength of Hooked Bars in High-Strength Concrete
    Hamad, Bilal S.
    Abs, Charbel. D. Bou
    [J]. ACI STRUCTURAL JOURNAL, 2009, 106 (06) : 831 - 839
  • [5] Performance evaluation of normal- and high-strength concrete column specimens reinforced longitudinally with different ratios of GFRP bars
    Hasan, Hayder Alaa
    Karim, Hogr
    Goaiz, Hussam A.
    Cabe, Aidan M.
    Sheikh, M. Neaz
    Hadi, Muhammad N. S.
    [J]. STRUCTURES, 2023, 47 : 1428 - 1440
  • [6] BOND BEHAVIOR OF NORMAL AND HIGH-STRENGTH FIBER REINFORCED-CONCRETE
    EZELDIN, AS
    BALAGURU, PN
    [J]. ACI MATERIALS JOURNAL, 1989, 86 (05) : 515 - 524
  • [7] Flexural strength and ductility of reinforced normal- and high-strength concrete beams
    Pam, HJ
    Kwan, AKH
    Islam, MS
    [J]. PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2001, 146 (04) : 381 - 389
  • [8] Bond durability performance of sand-coated BFRP bars in high-strength fiber reinforced concrete
    Al-Hamrani, Abathar
    Alnahhal, Wael
    [J]. COMPOSITE STRUCTURES, 2023, 321
  • [9] Bond behaviour of normal- and high-strength recycled aggregate concrete
    Prince, M. John Robert
    Singh, Bhupinder
    [J]. STRUCTURAL CONCRETE, 2015, 16 (01) : 56 - 70
  • [10] Experimental Study of Normal- and High-Strength Concrete Confined with Fiber-Reinforced Polymers
    Cui, C.
    Sheikh, S. A.
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2010, 14 (05) : 553 - 561