Intrinsic and routine quality of serum total potassium measurement as investigated by split sample measurement with an ion chromatography candidate reference method

被引:0
|
作者
Thienpont, LM [1 ]
Van Nuwenborg, JE [1 ]
Stöckl, D [1 ]
机构
[1] State Univ Ghent, Fac Farmaceut Wetenschappen, B-9000 Ghent, Belgium
关键词
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
We evaluated the intrinsic quality of eight routine test systems for the measurement of serum total potassium (K+), as well as the routine quality of four of these systems, using a group of 60 single-donation serum samples that had been certified with an ion chromatography reference method. The intrinsic quality of the tests was evaluated by analysis of the sera in the manufacturers' application laboratories under strict internal quality control. The routine quality was evaluated by analysis of the same sera in five (per system) routine laboratories under daily working conditions. The results of the study were interpreted in light of the most stringent specifications derived from the biological variation of K+, which require limits of 6.3% for total error and 1.6% for systematic error. The study revealed that the intrinsic quality of all systems was excellent. None of the test systems yielded a substantial number of results outside the 6.3% total error limit, and only one test system exceeded the 1.6% systematic error limit. The majority of the routine laboratories reproduced the manufacturers' intrinsic quality. In particular, most laboratories satisfied the 6.3% total error limit. However, several laboratories exceeded the 1.6% systematic error limit. Generally, there was a considerable difference in quality between the participating laboratories. This showed that the major problems for serum K+ analysis (for samples with no unusual matrices and with concentrations within the reference interval) are at the routine laboratory.
引用
收藏
页码:849 / 857
页数:9
相关论文
共 50 条
  • [21] Validation of 5 routine assays for serum free testosterone with a candidate reference measurement procedure based on ultrafiltration and isotope dilution-gas chromatography-mass spectrometry
    Van Uytfanghe, K
    Stöckl, D
    Kaufman, JM
    Fiers, T
    De Leenheer, A
    Thienpont, LM
    CLINICAL BIOCHEMISTRY, 2005, 38 (03) : 253 - 261
  • [22] Validation of candidate reference methods based on ion chromatography for determination of total sodium, potassium, calcium and magnesium in serum through comparison with flame atomic emission and absorption spectrometry
    Thienpont, LM
    VanNuwenborg, JE
    Reinauer, H
    Stockl, D
    CLINICAL BIOCHEMISTRY, 1996, 29 (06) : 501 - 508
  • [23] Determination of serum glucose by isotope dilution liquid chromatography-tandem mass spectrometry: a candidate reference measurement procedure
    Zhang, Tianjiao
    Zhang, Chuanbao
    Zhao, Haijian
    Zeng, Jie
    Zhang, Jiangtao
    Zhou, Weiyan
    Yan, Ying
    Wang, Yufei
    Wang, Mo
    Chen, Wenxiang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (26) : 7403 - 7411
  • [24] Determination of serum glucose by isotope dilution liquid chromatography-tandem mass spectrometry: a candidate reference measurement procedure
    Tianjiao Zhang
    Chuanbao Zhang
    Haijian Zhao
    Jie Zeng
    Jiangtao Zhang
    Weiyan Zhou
    Ying Yan
    Yufei Wang
    Mo Wang
    Wenxiang Chen
    Analytical and Bioanalytical Chemistry, 2016, 408 : 7403 - 7411
  • [25] Measurement of human serum unconjugated estriol without derivatization using liquid chromatography-tandem mass spectrometry candidate reference method and compared with two immunoassays
    Huang, Xianzhang
    Zhang, Qiaoxuan
    Zheng, Songbai
    Wang, Jianbing
    Han, Liqiao
    Lin, Haibiao
    Ke, Peifeng
    Zhuang, Junhua
    Cao, Zhimin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (24) : 6257 - 6267
  • [26] Measurement of human serum unconjugated estriol without derivatization using liquid chromatography-tandem mass spectrometry candidate reference method and compared with two immunoassays
    Xianzhang Huang
    Qiaoxuan Zhang
    Songbai Zheng
    Jianbing Wang
    Liqiao Han
    Haibiao Lin
    Peifeng Ke
    Junhua Zhuang
    Zhimin (Tim) Cao
    Analytical and Bioanalytical Chemistry, 2018, 410 : 6257 - 6267
  • [27] Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry Candidate Reference Method for Total Testosterone in Human Serum
    Botelho, Julianne Cook
    Shacklady, Christopher
    Cooper, Hans C.
    Tai, Susan S. -C.
    Van Uytfanghe, Katleen
    Thienpont, Linda M.
    Vesper, Hubert W.
    CLINICAL CHEMISTRY, 2013, 59 (02) : 372 - 380
  • [28] A selective ion monitoring gas chromatography mass spectrometry method for measurement of homovanillic acid in serum.
    Goodyear, N
    Dugaw, KA
    Jack, RM
    CLINICAL CHEMISTRY, 1998, 44 : A40 - A40
  • [29] Effect of low serum total protein on sodium and potassium measurement by ion-selective electrodes in critically ill patients
    Chow, E.
    Fox, N.
    Gama, R.
    BRITISH JOURNAL OF BIOMEDICAL SCIENCE, 2008, 65 (03) : 128 - 131
  • [30] Evaluation of an Isotope Dilution HPLC Tandem Mass Spectrometry Candidate Reference Measurement Procedure for Total 17-β Estradiol in Human Serum
    Botelho, Julianne Cook
    Ribera, Ashley
    Cooper, Hans C.
    Vesper, Hubert W.
    ANALYTICAL CHEMISTRY, 2016, 88 (22) : 11123 - 11129