Intrinsic and routine quality of serum total potassium measurement as investigated by split sample measurement with an ion chromatography candidate reference method

被引:0
|
作者
Thienpont, LM [1 ]
Van Nuwenborg, JE [1 ]
Stöckl, D [1 ]
机构
[1] State Univ Ghent, Fac Farmaceut Wetenschappen, B-9000 Ghent, Belgium
关键词
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
We evaluated the intrinsic quality of eight routine test systems for the measurement of serum total potassium (K+), as well as the routine quality of four of these systems, using a group of 60 single-donation serum samples that had been certified with an ion chromatography reference method. The intrinsic quality of the tests was evaluated by analysis of the sera in the manufacturers' application laboratories under strict internal quality control. The routine quality was evaluated by analysis of the same sera in five (per system) routine laboratories under daily working conditions. The results of the study were interpreted in light of the most stringent specifications derived from the biological variation of K+, which require limits of 6.3% for total error and 1.6% for systematic error. The study revealed that the intrinsic quality of all systems was excellent. None of the test systems yielded a substantial number of results outside the 6.3% total error limit, and only one test system exceeded the 1.6% systematic error limit. The majority of the routine laboratories reproduced the manufacturers' intrinsic quality. In particular, most laboratories satisfied the 6.3% total error limit. However, several laboratories exceeded the 1.6% systematic error limit. Generally, there was a considerable difference in quality between the participating laboratories. This showed that the major problems for serum K+ analysis (for samples with no unusual matrices and with concentrations within the reference interval) are at the routine laboratory.
引用
收藏
页码:849 / 857
页数:9
相关论文
共 50 条
  • [1] State-of-the-art of serum total calcium measurement as investigated by split-sample measurement with an ion chromatography candidate reference method
    VanNuwenborg, JE
    Stockl, D
    Thienpont, LM
    EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1997, 35 (04): : 297 - 300
  • [2] Evaluation of intrinsic and routine quality of serum total magnesium measurement
    Dewitte, K
    Stöckl, D
    Van de Velde, M
    Thienpont, LM
    CLINICA CHIMICA ACTA, 2000, 292 (1-2) : 55 - 68
  • [3] An improved reference method for serum cations measurement by ion chromatography
    Zou, Jihua
    Shen, Min
    Zhang, Man
    Tu, Minmin
    Feng, Rui
    Yan, Ying
    Zou, Bingde
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2018, 32 (06)
  • [4] A candidate reference method for serum potassium measurement by inductively coupled plasma mass spectrometry
    Yan, Ying
    Han, Bingqing
    Zeng, Jie
    Zhou, Weiyan
    Zhang, Tianjiao
    Zhang, Jiangtao
    Chen, Wenxiang
    Zhang, Chuanbao
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (10) : 1517 - 1522
  • [5] An improved candidate reference method for serum potassium measurement by inductively coupled plasma-mass spectrometry
    Zhang, Rui
    Ma, Huaian
    Li, Huiling
    Xu, Jing
    Zhang, Jianping
    Zhang, Yang
    Wang, Qingtao
    CLINICA CHIMICA ACTA, 2013, 420 : 146 - 149
  • [6] Ion chromatography as candidate reference method for the determination of chloride in human serum
    Shen, Min
    Tu, Minmin
    Zhang, Wei
    Zou, Jihua
    Zhang, Man
    Cao, Zheng
    Zou, Bingde
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2020, 34 (08)
  • [7] ION CHROMATOGRAPHY AS POTENTIAL REFERENCE METHODOLOGY FOR THE DETERMINATION OF TOTAL SODIUM AND POTASSIUM IN HUMAN SERUM
    THIENPONT, LM
    VANNUWENBORG, JE
    STOCKL, D
    JOURNAL OF CHROMATOGRAPHY A, 1995, 706 (1-2) : 443 - 450
  • [8] Trueness assessment of routine electrolytes measuring systems using the candidate reference method by ion chromatography
    Zhang, Rui
    Zhang, Shunli
    Wang, Qingtao
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2021, 81 (02): : 85 - 91
  • [9] Feasibility study of the use of frozen human sera in split-sample comparison of immunoassays with candidate reference measurement procedures for total thyroxine and total triiodothyronine measurements
    Thienpont, LM
    Van Uytfanghe, K
    Marriott, J
    Stokes, P
    Siekmann, L
    Kessler, A
    Bunik, D
    Tai, S
    CLINICAL CHEMISTRY, 2005, 51 (12) : 2303 - 2311
  • [10] Development of a simplified sample pretreatment procedure as part of an isotope dilution-liquid chromatography/tandem mass spectrometry candidate reference measurement procedure for serum total thyroxine
    Van Uytfanghe, K
    Stöckl, D
    Thienpont, LM
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (13) : 1539 - 1540