Automated 3D ultrasound elastography of the breast: a phantom validation study

被引:27
|
作者
Hendriks, Gijs A. G. M. [1 ]
Hollander, Branislav [1 ]
Menssen, Jan [1 ]
Milkowski, Andy [2 ]
Hansen, Hendrik H. G. [1 ]
de Korte, Chris L. [1 ]
机构
[1] Radboud Univ Nijmegen Med Ctr, Dept Radiol & Nucl Med, Med UltraSound Imaging Ctr MUSIC, Nijmegen, Netherlands
[2] Siemens Ultrasound, Issaquah, WA USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 07期
关键词
3D elastography; strain; ultrasound; ABVS; breast cancer; plane wave; MAMMOGRAPHY; MORTALITY; DENSITY; VECTOR; WOMEN; RISK;
D O I
10.1088/0031-9155/61/7/2665
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In breast cancer screening, the automated breast volume scanner (ABVS) was introduced as an alternative for mammography since the latter technique is less suitable for women with dense breasts. Although clinical studies show promising results, clinicians report two disadvantages: long acquisition times (> 90 s) introducing breathing artefacts, and high recall rates due to detection of many small lesions of uncertain malignant potential. Technical improvements for faster image acquisition and better discrimination between benign and malignant lesions are thus required. Therefore, the aim of this study was to investigate if 3D ultrasound elastography using plane-wave imaging is feasible. Strain images of a breast elastography phantom were acquired by an ABVS-mimicking device that allowed axial and elevational movement of the attached transducer. Pre-and post-deformation volumes were acquired with different constant speeds (between 1.25 and 40.0 mm s(-1)) and by three protocols: Go-Go (pre-and post-volumes with identical start and end positions), Go-Return (similar to Go-Go with opposite scanning directions) and Control (pre-and post-volumes acquired per position, this protocol can be seen as reference). Afterwards, 2D and 3D cross-correlation and strain algorithms were applied to the acquired volumes and the results were compared. The Go-Go protocol was shown to be superior with better strain image quality (CNRe and SNRe) than Go-Return and to be similar as Control. This can be attributed to applying opposite mechanical forces to the phantom during the Go-Return protocol, leading to out-of-plane motion. This motion was partly compensated by using 3D cross-correlation. However, the quality was still inferior to Go-Go. Since these results were obtained in a phantom study with controlled deformations, the effect of possible uncontrolled in vivo tissue motion artefacts has to be addressed in future studies. In conclusion, it seems feasible to implement 3D ultrasound quasi-static elastography on an ABVS-like system and to reduce scan times within one breath-hold (similar to 10 s) by plane-wave acquisitions.
引用
收藏
页码:2665 / 2679
页数:15
相关论文
共 50 条
  • [41] Diagnostic performance of 3D automated breast ultrasound (3D-ABUS) in a clinical screening setting-a retrospective study
    Wolterink, Femke Klein
    Ab Mumin, Nazimah
    Appelman, Linda
    Derks-Rekers, Monique
    Imhof-Tas, Mechli
    Lardenoije, Susanne
    van der Leest, Marloes
    Mann, Ritse M.
    EUROPEAN RADIOLOGY, 2024, 34 (8) : 5451 - 5460
  • [42] 3D printed phantom for high frequency ultrasound imaging
    Jacquet, Jean-Rene
    Levassort, Franck
    Ossant, Frederic
    Gregoire, Jean-Marc
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [43] Development of automated detection and classification methods of masses on 3D breast ultrasound images
    Hara, T
    Fukuoka, D
    Fujita, H
    Endo, T
    Moon, WK
    CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 794 - 799
  • [44] Multiplanar Reconstructions of 3D Automated Breast Ultrasound Improve Lesion Differentiation by Radiologists
    Van Zelst, Jan C. M.
    Platel, Bram
    Karssemeijer, Nico
    Mann, Ritse M.
    ACADEMIC RADIOLOGY, 2015, 22 (12) : 1489 - 1496
  • [45] A Hierarchical Model for Automated Breast Lesion Detection from Ultrasound 3D data
    Deng, Yinhui
    Liu, Weiping
    Jago, James
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 145 - 148
  • [46] Automatic Nipple Detection on 3D Images of an Automated Breast Ultrasound System (ABUS)
    Moghaddam, Mandana Javanshir
    Tan, Tao
    Karssemeijer, Nico
    Platel, Bram
    MEDICAL IMAGING 2014: IMAGE PROCESSING, 2014, 9034
  • [47] Automated 3D ultrasound image segmentation to aid breast cancer image interpretation
    Gu, Peng
    Lee, Won-Mean
    Roubidoux, Marilyn A.
    Yuan, Jie
    Wang, Xueding
    Carson, Paul L.
    ULTRASONICS, 2016, 65 : 51 - 58
  • [48] A hybrid method towards automated nipple detection in 3D breast ultrasound images
    Wang, Lei
    Boehler, Tobias
    Zoehrer, Fabian
    Georgii, Joachim
    Rauh, Claudia
    Fasching, Peter A.
    Brehm, Barbara
    Schulz-Wendtland, Ruediger
    Beckmann, Matthias W.
    Uder, Michael
    Hahn, Horst K.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 2869 - 2872
  • [49] A 3D Elastography System based on the Concept of Ultrasound-Computed Tomography for In Vivo Breast Examination
    Gennisson, Jean-Luc
    Deffieux, Thomas
    Sinkus, Ralph
    Annie, Philippe
    Pernot, Mathieu
    Cudeiro, Frederic
    Montaldo, Gabriel
    Tanter, Mickaeel
    Fink, Mathias
    Bercoff, Jeremy
    2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 1037 - +
  • [50] Nonlinear characterization of breast cancer using multi-compression 3D ultrasound elastography in vivo
    Sayed, Ahmed
    Layne, Ginger
    Abraham, Jame
    Mukdadi, Osama
    ULTRASONICS, 2013, 53 (05) : 979 - 991