Cone Beam Computed Tomography, A Low-Dose Imaging Technique in the Postoperative Assessment of Cochlear Implantation

被引:78
|
作者
Ruivo, Joana [2 ]
Mermuys, Koen [1 ]
Bacher, Klaus [3 ]
Kuhweide, Rudolf [4 ]
Offeciers, Erwin [5 ]
Casselman, Jan W. [1 ]
机构
[1] AZ St Jan Hosp, Dept Radiol, B-8000 Brugge, Belgium
[2] Hosp Santa Maria, Serv Imagiol Neurol, Lisbon, Portugal
[3] Univ Ghent, Dept Med Phys & Radiat Protect, B-9000 Ghent, Belgium
[4] AZ St Jan Hosp, Dept Otorhinolaryngol, B-8000 Brugge, Belgium
[5] St Augustinus Hosp, Univ Dept Otolaryngol, Antwerp, Belgium
关键词
Inner ear; Cochlear implants; Cone beam computed tomography; Radiation dosage; Temporal bones; INSERTION DEPTH; MIDDLE-EAR; CT; ELECTRODE;
D O I
10.1097/MAO.0b013e31819679f9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Cone beam computed tomography (CBCT) has become an extremely useful technique for dentomaxillofacial imaging because it provides clear images of highly contrasted structures. Previous studies evaluating the applicability of this technique in otologic imaging were very encouraging but were only performed in vitro on temporal bone specimens. The intracochlear positioning of the individual electrodes after cochlear implantation by means of CBCT has not yet been shown in vivo. Objective: We describe a protocol for in vivo postoperative imaging of cochlear implants by CBCT. Moreover, the effective dose was measured and compared with the effective dose used on 4- and 16-slice multislice computed tomography (MSCT) by using a RANDO-phantom. Main Outcome Measure: Developing a protocol for in vivo postoperative imaging of cochlear implants by CBCT. Results: CBCT provides high-resolution and almost artifact-free multiplanar reconstruction images allowing assessment of the precise intracochlear position of the electrode and visualization of each of the individual contacts. The calculated effective dose of the used CBCT and MSCT acquisitions is 80 mu sv for the CBCT, 3,600 mu sv for the 16-slice computed tomography, and 4,800 mu sv for the 4-slice computed tomography. Conclusion: These preliminary results suggests that, for in vivo postoperative evaluation of cochlear implants, CBCT can provide at least the same information as conventional radiography, digital radiograph, and MSCT but in a more comfortable and a much more safer way.
引用
收藏
页码:299 / 303
页数:5
相关论文
共 50 条
  • [41] Low-dose cone-beam computed tomography in simulated condylar erosion detection: a diagnostic accuracy study
    Noha Saleh Abu-Taleb
    Dina Mohamed ElBeshlawy
    Oral Radiology, 2021, 37 : 427 - 435
  • [42] Detectability of Osseous Lesions with a Pre-Programmed Low-Dose Protocol for Cone-Beam Computed Tomography
    Dobelin, Quirin
    Stadlinger, Bernd
    Wiedemeier, Daniel B.
    Bichsel, Dominique
    Rucker, Martin
    Valdec, Silvio
    APPLIED SCIENCES-BASEL, 2020, 10 (14):
  • [43] Influence of sharpening filters on the detection of root fractures using low-dose cone-beam computed tomography
    Gonzalez, Alexandra Robles
    Tosoni, Guilherme Monteiro
    Freitas, Deborah Queiroz
    Oliveira, Matheus L.
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (07) : 4797 - 4803
  • [44] Combining Acceleration Techniques for Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction
    Huang, Hsuan-Ming
    Hsiao, Ing-Tsung
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [45] Fast, Iterative, Low-Dose, Cone-Beam Computed Tomography Reconstruction Using a Gradient Projection Algorithm
    Park, J.
    Song, B.
    Kim, J.
    Park, S.
    Kim, H.
    Suh, T.
    Liu, Z.
    Song, W.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [46] Low-dose cone-beam computed tomography in simulated condylar erosion detection: a diagnostic accuracy study
    Abu-Taleb, Noha Saleh
    ElBeshlawy, Dina Mohamed
    ORAL RADIOLOGY, 2021, 37 (03) : 427 - 435
  • [47] Measuring peri-implant bone lesions using low-dose cone-beam computed tomography
    Leisner, Laura Christine
    Tasaka, Akinori
    Trebing, Charlotte Theresa
    Hilgenfeld, Tim
    Kosinski, Matthias Adalbert
    Kronsteiner, Dorothea
    Rammelsberg, Peter
    Schwindling, Franz Sebastian
    JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (02) : 326 - 332
  • [48] Influence of sharpening filters on the detection of root fractures using low-dose cone-beam computed tomography
    Alexandra Robles González
    Guilherme Monteiro Tosoni
    Deborah Queiroz Freitas
    Matheus L. Oliveira
    Clinical Oral Investigations, 2022, 26 : 4797 - 4803
  • [49] Evaluation of various low-dose cone-beam computed tomography protocols in the diagnosis of specific condylar defects
    Jager, Fabian
    Jaeger, Antje
    Temming, Alexa
    Rehm, Phillip
    Bumann, Axel
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2021, 159 (04) : 491 - U39
  • [50] Comparative study of image quality and radiation dose of cone beam and low-dose multislice computed tomography - an in-vitro investigation
    Elisabeth Hofmann
    Matthias Schmid
    Martin Sedlmair
    Rosemarie Banckwitz
    Ursula Hirschfelder
    Michael Lell
    Clinical Oral Investigations, 2014, 18 : 301 - 311