Cone Beam Computed Tomography, A Low-Dose Imaging Technique in the Postoperative Assessment of Cochlear Implantation

被引:78
|
作者
Ruivo, Joana [2 ]
Mermuys, Koen [1 ]
Bacher, Klaus [3 ]
Kuhweide, Rudolf [4 ]
Offeciers, Erwin [5 ]
Casselman, Jan W. [1 ]
机构
[1] AZ St Jan Hosp, Dept Radiol, B-8000 Brugge, Belgium
[2] Hosp Santa Maria, Serv Imagiol Neurol, Lisbon, Portugal
[3] Univ Ghent, Dept Med Phys & Radiat Protect, B-9000 Ghent, Belgium
[4] AZ St Jan Hosp, Dept Otorhinolaryngol, B-8000 Brugge, Belgium
[5] St Augustinus Hosp, Univ Dept Otolaryngol, Antwerp, Belgium
关键词
Inner ear; Cochlear implants; Cone beam computed tomography; Radiation dosage; Temporal bones; INSERTION DEPTH; MIDDLE-EAR; CT; ELECTRODE;
D O I
10.1097/MAO.0b013e31819679f9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Cone beam computed tomography (CBCT) has become an extremely useful technique for dentomaxillofacial imaging because it provides clear images of highly contrasted structures. Previous studies evaluating the applicability of this technique in otologic imaging were very encouraging but were only performed in vitro on temporal bone specimens. The intracochlear positioning of the individual electrodes after cochlear implantation by means of CBCT has not yet been shown in vivo. Objective: We describe a protocol for in vivo postoperative imaging of cochlear implants by CBCT. Moreover, the effective dose was measured and compared with the effective dose used on 4- and 16-slice multislice computed tomography (MSCT) by using a RANDO-phantom. Main Outcome Measure: Developing a protocol for in vivo postoperative imaging of cochlear implants by CBCT. Results: CBCT provides high-resolution and almost artifact-free multiplanar reconstruction images allowing assessment of the precise intracochlear position of the electrode and visualization of each of the individual contacts. The calculated effective dose of the used CBCT and MSCT acquisitions is 80 mu sv for the CBCT, 3,600 mu sv for the 16-slice computed tomography, and 4,800 mu sv for the 4-slice computed tomography. Conclusion: These preliminary results suggests that, for in vivo postoperative evaluation of cochlear implants, CBCT can provide at least the same information as conventional radiography, digital radiograph, and MSCT but in a more comfortable and a much more safer way.
引用
收藏
页码:299 / 303
页数:5
相关论文
共 50 条
  • [21] Optimising the parameters of cochlear implant imaging with cone-beam computed tomography
    Soederqvist, Samuel
    Sivonen, Ville
    Aarnisalo, Antti
    Karppi, Harri
    Sinkkonen, Saku T.
    Koivisto, Juha
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (05) : 462 - 470
  • [22] Cone-beam computed tomography: a new low dose, high resolution imaging technique of the wrist, presentation of three cases with technique
    Jens De Cock
    Koen Mermuys
    Jean Goubau
    Simon Van Petegem
    Brecht Houthoofd
    Jan W. Casselman
    Skeletal Radiology, 2012, 41 : 93 - 96
  • [23] Cone-beam computed tomography: a new low dose, high resolution imaging technique of the wrist, presentation of three cases with technique
    De Cock, Jens
    Mermuys, Koen
    Goubau, Jean
    Van Petegem, Simon
    Houthoofd, Brecht
    Casselman, Jan W.
    SKELETAL RADIOLOGY, 2012, 41 (01) : 93 - 96
  • [24] Optimization of orofacial cleft imaging protocols using device-specific low-dose cone-beam computed tomography
    Shujaat, Sohaib
    Vasconcelos, Karla de Faria
    Kesztyus, Artur
    Fontenele, Rocharles Cavalcante
    Oliveira-Santos, Nicolly
    Nagy, Krisztian
    Shaheen, Eman
    Jacobs, Reinhilde
    JOURNAL OF ORAL REHABILITATION, 2024, 51 (09) : 1712 - 1720
  • [25] Kilovoltage cone-beam computed tomography imaging dose estimation and optimization: Need of daily cone-beam computed tomography
    Trivedi, Gaurav
    Dixit, Chandra K.
    Oinam, Arun S.
    Kapoor, Rakesh
    Bahl, Amit
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (03) : 470 - 474
  • [26] Dose delivered to the patient by megavoltage cone beam computed tomography imaging
    Isambert, A.
    Ferreira, I. H.
    Bossi, A.
    Beaudre, A.
    Nicula, L. E.
    Lefkopoulos, D.
    CANCER RADIOTHERAPIE, 2009, 13 (05): : 358 - 364
  • [27] Imaging dose from cone beam computed tomography in radiation therapy
    Alaei, Parham
    Spezi, Emiliano
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (07): : 647 - 658
  • [28] Cone-beam computed tomography, a new low-dose three-dimensional imaging technique for assessment of bone erosions in rheumatoid arthritis: reliability assessment and comparison with conventional radiography - a BARFOT study
    Aurell, Y.
    Andersson, M. L. E.
    Forslind, K.
    SCANDINAVIAN JOURNAL OF RHEUMATOLOGY, 2018, 47 (03) : 173 - 177
  • [29] Cone beam computed tomography and low-dose multislice computed tomography in orthodontics and dentistry A comparative evaluation on image quality and radiation exposure
    Hofmann, Elisabeth
    Schmid, Matthias
    Lell, Michael
    Hirschfelder, Ursula
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2014, 75 (05): : 384 - 398
  • [30] Reproducibility of three-dimensional cephalometric landmarks in cone-beam and low-dose computed tomography
    R. Olszewski
    L. Frison
    M. Wisniewski
    J. M. Denis
    S. Vynckier
    G. Cosnard
    F. Zech
    H. Reychler
    Clinical Oral Investigations, 2013, 17 : 285 - 292