Evaluation of the effect of tooth and dental restoration material on electron dose distribution and production of photon contamination in electron beam radiotherapy

被引:3
|
作者
Toossi, Mohammad Taghi Bahreyni [1 ]
Ghorbani, Mahdi [1 ]
Akbari, Fatemeh [2 ]
Mehrpouyan, Mohammad [3 ,4 ]
Sabet, Leila Sobhkhiz [2 ]
机构
[1] Mashhad Univ Med Sci, Med Phys Res Ctr, Mashhad, Iran
[2] Reza Radiat Oncol Ctr, Dept Med Phys, Mashhad, Iran
[3] Sabzevar Univ Med Sci, Bioinformat Res Ctr, Sabzevar, Iran
[4] Sabzevar Univ Med Sci, Radiol & Radiotherapy Dept, Fac Med, Sabzevar, Iran
关键词
Monte Carlo simulation; Electron mode; Tooth; Dental restoration material; THERAPY;
D O I
10.1007/s13246-015-0404-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study is to evaluate the effect of tooth and dental restoration materials on electron dose distribution and photon contamination production in electron beams of a medical linac. This evaluation was performed on 8, 12 and 14 MeV electron beams of a Siemens Primus linac. MCNPX Monte Carlo code was utilized and a 10 x 10 cm(2) applicator was simulated in the cases of tooth and combinations of tooth and Ceramco C3 ceramic veneer, tooth and Eclipse alloy and tooth and amalgam restoration materials in a soft tissue phantom. The relative electron and photon contamination doses were calculated for these materials. The presence of tooth and dental restoration material changed the electron dose distribution and photon contamination in phantom, depending on the type of the restoration material and electron beam's energy. The maximum relative electron dose was 1.07 in the presence of tooth including amalgam for 14 MeV electron beam. When 100.00 cGy was prescribed for the reference point, the maximum absolute electron dose was 105.10 cGy in the presence of amalgam for 12 MeV electron beam and the maximum absolute photon contamination dose was 376.67 mu Gy for tooth in 14 MeV electron beam. The change in electron dose distribution should be considered in treatment planning, when teeth are irradiated in electron beam radiotherapy. If treatment planning can be performed in such a way that the teeth are excluded from primary irradiation, the potential errors in dose delivery to the tumour and normal tissues can be avoided.
引用
收藏
页码:113 / 122
页数:10
相关论文
共 45 条
  • [31] Effect of the Gaussian distribution parameters of the electron beam generated at the target on the simulated x-ray dose
    Assalmi, Mustapha
    Diaf, E. L. Yamani
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (03)
  • [32] Comparison between TG-51 and TRS-398: electron contamination effect on photon beam-quality specification
    Medina, AL
    Teijeiro, A
    Salvador, F
    Medal, D
    Vazquez, J
    Salgado, M
    Carrion, MC
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (01): : 17 - 32
  • [33] Response to "Comment on 'The effect of electron contamination on scatter correction factors for photon beam dosimetry' " [Med, Phys. 27, 616 (2000)]
    Venselaar, J
    Heukelom, S
    Jager, N
    Mijnheer, D
    van der Laarse, R
    van Gasteren, H
    van Kleffens, H
    Westermann, C
    MEDICAL PHYSICS, 2000, 27 (03) : 617 - 617
  • [34] Magnetic confinement of electron and photon beam radiotherapy dose profiles - A Monte Carlo study with a realistic non-uniform longitudinal magnetic field (WIP)
    Chen, Y
    Becchetti, F
    Bielajew, A
    Litzenberg, D
    Moran, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1514 - 1514
  • [35] Experimental evaluation of out-of-field dose for different high-energy electron beams and applicators used in external beam radiotherapy
    Gul, Osman Vefa
    RADIATION PHYSICS AND CHEMISTRY, 2024, 215
  • [36] Screening effect and possibility of diagnostics of atomic nuclei and electron distribution in structured material using bremsstrahlung beam of relativistic electrons
    V. K. Grishin
    Journal of Surface Investigation. X-ray, Synchrotron and Neutron Techniques, 2008, 2 : 327 - 330
  • [37] Screening Effect and Possibility of Diagnostics of Atomic Nuclei and Electron Distribution in Structured Material Using Bremsstrahlung Beam of Relativistic Electrons
    Grishin, V. K.
    JOURNAL OF SURFACE INVESTIGATION, 2008, 2 (02): : 327 - 330
  • [38] Evaluation of a mixed beam therapy for postmastectomy breast cancer patients: Bolus electron conformal therapy combined with intensity modulated photon radiotherapy and volumetric modulated photon arc therapy
    Zhang, Rui
    Heins, David
    Sanders, Mary
    Guo, Beibei
    Hogstrom, Kenneth
    MEDICAL PHYSICS, 2018, 45 (07) : 2912 - 2924
  • [39] Effect of variation of silicone rubber RTV 52 and bluesil catalyst 60 R composition on bolus material for electron beam radiotherapy application
    Hidayanto, Eko
    Sutanto, Heri
    Marhaendrajaya, Indras
    Jaya, Gede Wiratma
    Arifin, Zaenal
    Anam, Choirul
    Widyastuti Setjadiningrat Kuntjoro, Lidya Purna
    Saraswati, Galih Puspa
    Dougherty, Geoff
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (04)
  • [40] High-density dental implants and radiotherapy planning: evaluation of effects on dose distribution using pencil beam convolution algorithm and Monte Carlo method
    Catli, Serap
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (05): : 46 - 52