Evaluation of the effect of tooth and dental restoration material on electron dose distribution and production of photon contamination in electron beam radiotherapy

被引:3
|
作者
Toossi, Mohammad Taghi Bahreyni [1 ]
Ghorbani, Mahdi [1 ]
Akbari, Fatemeh [2 ]
Mehrpouyan, Mohammad [3 ,4 ]
Sabet, Leila Sobhkhiz [2 ]
机构
[1] Mashhad Univ Med Sci, Med Phys Res Ctr, Mashhad, Iran
[2] Reza Radiat Oncol Ctr, Dept Med Phys, Mashhad, Iran
[3] Sabzevar Univ Med Sci, Bioinformat Res Ctr, Sabzevar, Iran
[4] Sabzevar Univ Med Sci, Radiol & Radiotherapy Dept, Fac Med, Sabzevar, Iran
关键词
Monte Carlo simulation; Electron mode; Tooth; Dental restoration material; THERAPY;
D O I
10.1007/s13246-015-0404-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study is to evaluate the effect of tooth and dental restoration materials on electron dose distribution and photon contamination production in electron beams of a medical linac. This evaluation was performed on 8, 12 and 14 MeV electron beams of a Siemens Primus linac. MCNPX Monte Carlo code was utilized and a 10 x 10 cm(2) applicator was simulated in the cases of tooth and combinations of tooth and Ceramco C3 ceramic veneer, tooth and Eclipse alloy and tooth and amalgam restoration materials in a soft tissue phantom. The relative electron and photon contamination doses were calculated for these materials. The presence of tooth and dental restoration material changed the electron dose distribution and photon contamination in phantom, depending on the type of the restoration material and electron beam's energy. The maximum relative electron dose was 1.07 in the presence of tooth including amalgam for 14 MeV electron beam. When 100.00 cGy was prescribed for the reference point, the maximum absolute electron dose was 105.10 cGy in the presence of amalgam for 12 MeV electron beam and the maximum absolute photon contamination dose was 376.67 mu Gy for tooth in 14 MeV electron beam. The change in electron dose distribution should be considered in treatment planning, when teeth are irradiated in electron beam radiotherapy. If treatment planning can be performed in such a way that the teeth are excluded from primary irradiation, the potential errors in dose delivery to the tumour and normal tissues can be avoided.
引用
收藏
页码:113 / 122
页数:10
相关论文
共 45 条
  • [21] Influence of initial electron beam parameters on Monte Carlo calculated absorbed dose distributions for radiotherapy photon beams
    Tzedakis, A
    Damilakis, JE
    Mazonakis, M
    Stratakis, J
    Varveris, H
    Gourtsoyiannis, N
    MEDICAL PHYSICS, 2004, 31 (04) : 907 - 913
  • [22] EFFECT OF AIR CAVITIES ON DOSE DISTRIBUTION OF HIGH-ENERGY ELECTRON AND PHOTON BEAMS
    NUSSLIN, F
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 574 - 574
  • [23] Evaluation of PENFAST - A fast Monte Carlo code for dose calculations in photon and electron radiotherapy treatment planning
    Habib, B.
    Poumarede, B.
    Tola, F.
    Barthe, J.
    PHYSICA MEDICA, 2010, 26 (01) : 17 - 25
  • [24] A Monte Carlo study on dose enhancement and photon contamination production by various nanoparticles in electron mode of a medical linac
    Toossi, Mohammad Taghi Bahreyni
    Ghorbani, Mahdi
    Sabet, Leila Sobhkhiz
    Akbari, Fateme
    Mehrpouyan, Mohammad
    NUKLEONIKA, 2015, 60 (03) : 489 - 496
  • [25] Effect of age-dependent bone electron density on the calculated dose distribution from kilovoltage and megavoltage photon and electron radiotherapy in paediatric MRI-only treatment planning
    Zeinali-Rafsanjani, B.
    Faghihi, R.
    Mosleh-Shirazi, M. A.
    Saeedi-Moghadam, M.
    Jalli, R.
    Sina, S.
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1081):
  • [26] Dose Perturbation Caused by MOSFET Dosimeter during in Vivo Dosimetry of Photon and Electron Beam Radiotherapy - a Film Dosimetry Study
    Manigandan, D.
    Ganesan, S.
    Aruna, P.
    Bharandharani, G.
    Subramani, V.
    Sharma, S.
    Rath, G.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [27] Evaluation of optically stimulated luminescence (OSL) dosimetry for high-energy photon and electron beam measurements in radiotherapy
    Yukihara, E.
    Mardirossian, G.
    Ahmad, S.
    Mirzasadeghi, M.
    MEDICAL PHYSICS, 2006, 33 (06) : 2100 - 2100
  • [28] Calculation accuracy evaluation for distribution of minority charge carriers generated by electron beam in semiconducting material
    Stepovich, M.A.
    Izvestiya Akademii Nauk. Ser. Fizicheskaya, 2003, 67 (04): : 588 - 592
  • [29] Step-size effect on calculated photon and electron beam Cherenkov-to-dose conversion factors
    Zlateva, Yana
    Muir, Bryan R.
    El Naqa, Issam
    Seuntjens, Jan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 78 : 32 - 37
  • [30] Enhancing benefits of bolus use through minimising the effect of air-gaps on dose distribution in photon beam radiotherapy
    Bahhous, Karim
    Zerfaoui, Mustapha
    Rahmouni, Abdelaali
    El Khayati, Naima
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2021, 20 (02) : 210 - 216