Performance analysis of an earth-to-air heat exchanger assisted by a wind tower for passive cooling of buildings in arid and hot climate

被引:76
|
作者
Benhammou, M. [1 ]
Draoui, B. [1 ]
Zerrouki, M. [1 ]
Marif, Y. [1 ]
机构
[1] Ctr Dev Energies Renouvelables, Div Convers Therm & Thermodynam, Unite Rech Energies Renouvelables Milieu Saharien, Adrar, Algeria
关键词
Passive cooling; Earth-to-air heat exchanger; Wind tower; Air flow velocity; Daily cooling potential; PRESSURE COEFFICIENTS; NUMERICAL-SIMULATION; THERMAL PERFORMANCE; TUBE SYSTEM; DESIGN; VENTILATION; REGIONS; FLOW; SOIL;
D O I
10.1016/j.enconman.2014.11.042
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, a new design of passive cooling system which consists in an Earth-to-Air Heat Exchanger (EAHE) assisted by a wind tower is presented. This system is intended for the summer cooling in hot and arid regions of Algeria. A transient analytical model was developed in order to investigate the influence of design parameters on the performance of the EAHE. The model of the EAHE is validated against both theoretical and experimental data carried out by other authors. Since it is well-known that the performance of the EAHE systems is more influenced by the air flow velocity, another model was presented to predict the air velocity inside the buried pipe. Moreover, a burying depth of 2 m was adopted and the period under consideration is July where the ambient temperature exceeds 45 degrees C. This study was also extended to examine the behaviour of system during the whole year. In addition, a sensitivity survey was curried out to investigate the influence of tower and pipe dimensions on the air flow velocity and the performances of the EAHE. Results showed that the wind tower dimensions (height, cross section) have not an important impact compared to the pipe dimensions (length, diameter). It is found that a tower with a total height of 5.1 m and a cross section area of 0.57 m(2) can generate an air flow rate of 592.61 m(3)/h. Furthermore, it has been also observed that the daily cooling potential reached a maximum of 30.7 kWh corresponding to a pipe length of 70 m. The cooling effectiveness of the system is compared to that of traditional passive cooling system consisting in a wind tower with wet surfaces. The results indicated that the ambient air after passing through the wind tower coupled to the EAHE is colder than of that of the leaving the conventional cooling tower. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [41] THERMAL PERFORMANCE OF EARTH-AIR HEAT EXCHANGER SYSTEMS FOR COOLING APPLICATIONS IN RESIDENTIAL BUILDINGS
    Ghaith, Fadi A.
    Razzaq, Habib Ur
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2018, VOL 6A, 2019,
  • [42] Influence of parameters on performance of earth air heat exchanger in hot-dry climate
    Singh, Baljit
    Kumar, Rakesh
    Asati, A. K.
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2018, 32 (11) : 5457 - 5463
  • [43] Techno-economic analysis and energy performance of a geothermal earth-to-air heat exchanger (EAHE) system in residential buildings: A case study
    Mostafaeipour, Ali
    Goudarzi, Hossein
    Khanmohammadi, Mohammadali
    Jahangiri, Mehdi
    Sedaghat, Ahmad
    Norouzianpour, Hirbod
    Chowdhury, Shahariar
    Techato, Kuaanan
    Issakhov, Alibek
    Almutairi, Khalid
    Dehshiri, Seyyed Jalaladdin Hosseini
    ENERGY SCIENCE & ENGINEERING, 2021, 9 (10) : 1807 - 1825
  • [44] Performance analysis of earth-pipe-air heat exchanger for summer cooling
    Bansal, Vikas
    Misra, Rohit
    Das Agrawal, Ghanshyam
    Mathur, Jyotirmay
    ENERGY AND BUILDINGS, 2010, 42 (05) : 645 - 648
  • [45] Performance of wind towers for solar passive cooling in hot arid regions
    Sabzevari, A.
    Golneshan, A.A.
    Yaghoubi, M.A.
    ASME-JSES-JSME International Solar Energy Conference, 1991, : 97 - 101
  • [46] Transient Analysis of Earth-to-Air Heat Exchanger for a Home-Scale Greenhouse
    Bastien, D.
    Athienitis, A. K.
    INTERNATIONAL SYMPOSIUM ON HIGH TECHNOLOGY FOR GREENHOUSE SYSTEMS: GREENSYS2009, 2011, (893): : 477 - 484
  • [47] Energy and thermal analysis of an innovative earth-to-air heat exchanger: Experimental investigations
    Taurines, Kevin
    Girous-Julien, Stephanie
    Menezo, Christophe
    ENERGY AND BUILDINGS, 2019, 187 : 1 - 15
  • [48] Experimental analysis and model verification of a new earth-to-air heat exchanger system
    Liu, Zhengxuan
    Roccamena, Letizia
    El Mankibi, Mohamed
    Yu, Zhun
    Yang, Tingting
    Sun, Ying
    Sun, Pengcheng
    Li, Shuisheng
    Zhang, Guoqiang
    2018 4TH INTERNATIONAL CONFERENCE ON RENEWABLE ENERGIES FOR DEVELOPING COUNTRIES (REDEC), 2018,
  • [49] Thermal Analysis of a Generic Earth-to-Air Heat Exchanger Coupled with a Room during the Summer Season in a Desert Climate
    Maytorena, V. M.
    Hinojosa, J. F.
    JOURNAL OF ENERGY ENGINEERING, 2022, 148 (02)
  • [50] Investigation on Thermal Performance of Earth-to-Air Heat Exchanger Under Different Operation Strategies
    Liu, Qing-Gong
    Du, Zhen-Yu
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2020, 41 (02): : 420 - 429