Measurement of output factors for small photon beams

被引:147
|
作者
Sauer, Otto A. [1 ]
Wilbert, Juergen [1 ]
机构
[1] Univ Wurzburg, Klin Strahlentherapie, D-97080 Wurzburg, Germany
关键词
output factors; small photon beams; dosimetry; radiation detectors;
D O I
10.1118/1.2734383
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A variety of detectors and procedures for the measurement of small field output factors are discussed in the current literature. Different detectors with or without corrections are recommended. Correction factors are often derived by Monte Carlo methods, where the bias due to approximations in the model is difficult to judge. Over that, results appear to be contradictory in some cases. In this work, output factors were measured for field sizes from 4 mm up to 180 mm side length with different detectors. A simple linear correction for the energy response of solid state detectors is proposed. This led to identical values down to 8 mm field size, as long as the size of the detector is small against the field size. The correction was of the order of a few percent. For a shielded silicon diode it was well below 1%. A physically meaningful function is proposed in order to calculate output factors for arbitrary field sizes with high accuracy. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1983 / 1988
页数:6
相关论文
共 50 条
  • [41] The effective point of measurement for depth-dose measurements in small MV photon beams with different detectors
    Wegener, Sonja
    Sauer, Otto A.
    [J]. MEDICAL PHYSICS, 2019, 46 (11) : 5209 - 5215
  • [42] MEASUREMENT OF DOSE DISTRIBUTIONS FROM NEUTRON AND PHOTON BEAMS
    STEDEFORD, B
    BRATBY, R
    DAMESICK, M
    BERRY, RJ
    GOODHEAD, D
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (01): : 153 - 153
  • [43] TIME-RESOLVED MEASUREMENT OF AN OUTPUT BEAMS INTENSITY
    KOZELOV, AV
    LEBEDEV, AA
    MEDVED, SA
    MIKHAILOV, YV
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1994, 37 (02) : 160 - 162
  • [44] THEORY OF 2-PHOTON MEASUREMENT OF LASER OUTPUT
    ROWE, HE
    LI, T
    [J]. IEEE JOURNAL OF QUANTUM ELECTRONICS, 1970, QE 6 (01) : 49 - &
  • [45] THEORY OF 2-PHOTON MEASUREMENT OF LASER OUTPUT
    ROWE, HE
    LI, T
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1968, 58 (11) : 1565 - &
  • [46] Monte Carlo physical dosimetry for small photon beams
    Perucha, M
    Sánchez-Doblado, F
    Rincón, M
    Leal, A
    Núnez, L
    Arráns, R
    Carrasco, E
    Sánchez-Calzado, JA
    Errazquin, L
    [J]. ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 555 - 559
  • [47] Characteristics and Dosimetric Parameters of Small Radiosurgery Photon Beams
    Ding, G.
    Coffey, C.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2800 - +
  • [48] Postal dosimetry audit test for small photon beams
    del Mar Espinosa, Maria
    Nunez, Luis
    Luis Muniz, Jose
    Ignacio Lagares, Juan
    Embid, Miguel
    Maria Gomez-Ros, Jose
    [J]. RADIOTHERAPY AND ONCOLOGY, 2012, 102 (01) : 135 - 141
  • [49] OUTPUT CALIBRATION IN SOLID WATER FOR HIGH-ENERGY PHOTON BEAMS
    REFT, CS
    [J]. MEDICAL PHYSICS, 1987, 14 (03) : 489 - 490
  • [50] OUTPUT CALIBRATION IN SOLID WATER FOR HIGH-ENERGY PHOTON BEAMS
    REFT, CS
    [J]. MEDICAL PHYSICS, 1989, 16 (02) : 299 - 301