Postal dosimetry audit test for small photon beams

被引:9
|
作者
del Mar Espinosa, Maria [1 ]
Nunez, Luis [1 ]
Luis Muniz, Jose [2 ]
Ignacio Lagares, Juan [2 ]
Embid, Miguel [3 ]
Maria Gomez-Ros, Jose [4 ]
机构
[1] Hosp Univ Puerta Hierro Majaclahonda, Majadahonda 28222, Spain
[2] CIEMAT, Unidad Fis Med, E-28040 Madrid, Spain
[3] CIEMAT, Div Metrol Radiac, E-28040 Madrid, Spain
[4] CIEMAT, Unidad Dosimetria Radiac, E-28040 Madrid, Spain
关键词
Radiotherapy quality assurance; Small beams; TLD; Postal audit; QUALITY-ASSURANCE NETWORK; RELATIVE OUTPUT FACTOR; PROFILE MEASUREMENTS; THERMO-LUMINESCENCE; SMALL FIELDS; RADIOTHERAPY; TLD; RADIOSURGERY; DETECTORS; THERAPY;
D O I
10.1016/j.radonc.2011.06.012
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Small radiation beams (<4 cm width) are being increasingly used in the delivery of advanced techniques as Intensity Modulated Radiotherapy (IMRT) and Stereotactic Radiosurgery (SRS). Dose measurements in small beams present challenges not encountered for larger beams. A postal audit with Thermoluminiscent Dosimeters (TLD) was developed to check the doses in small photon beams. A validation test in real conditions was carried out in fourteen centres. Material and methods: The TLD postal audit employs very small chips (1 x 1 x 1 mm(3)) of TLD-100 inserted at 5 and 10 cm of depth in a cylindrical PMMA phantom designed for this purpose. This experimental system is mailed to the audited centres to be irradiated with beams of 1 and 3 cm of side or diameter. The prescribed dose is 1.5 Gy at 10 cm. The properties of this system were studied experimentally and by Monte Carlo (MC) simulation, before the external test. Results: Deviations between the prescribed and measured absorbed doses are below 5% for 69% (1 x 1 cm(2) beam) and 64% (3 x 3 cm(2) beam) of the audited centres. When deviations are above 5%, their causes have been investigated and led to corrections. Conclusion: The developed postal audit is suitable to verify the absorbed doses in small photon beams with an accuracy of 2.9% (1s). (C) 2011 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 102 (2012) 135-141
引用
收藏
页码:135 / 141
页数:7
相关论文
共 50 条
  • [1] Feasibility of using glass bead TLDs for a postal dosimetry audit of MV radiotherapy photon beams
    Jafari, S. M.
    Distefano, G.
    Lee, J.
    Gouldstone, C.
    Mayles, H.
    Bradley, D. A.
    Spyrou, N. M.
    Nisbet, A.
    Clark, C. H.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S853 - S854
  • [2] Feasibility study of glass dosimeter postal dosimetry audit of high-energy radiotherapy photon beams
    Mizuno, Hideyuki
    Kanai, Tatsuaki
    Kusano, Yohsuke
    Ko, Susumu
    Ono, Mari
    Fukumura, Akifumi
    Abe, Kyoko
    Nishizawa, Kanae
    Shimbo, Munefumi
    Sakata, Suoh
    Ishikura, Satoshi
    Ikeda, Hiroshi
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 86 (02) : 258 - 263
  • [3] Validating dose rate calibration of radiotherapy photon beams through IAEA/WHO postal audit dosimetry service
    Jangda, Abdul Qadir
    Hussein, Sherali
    [J]. JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2012, 62 (05) : 490 - 493
  • [4] A methodology for TLD postal dosimetry audit of high-energy radiotherapy photon beams in non-reference conditions
    Izewska, Joanna
    Georg, Dietmar
    Bera, Pranabes
    Thwaites, David
    Arib, Mehenna
    Saravi, Margarita
    Sergieva, Katia
    Li, Kaibao
    Yip, Fernando Garcia
    Mahant, Ashok Kumar
    Bulski, Wojciech
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 (01) : 67 - 74
  • [5] External audit of photon beams by mailed film dosimetry: Feasibility study
    Novotny, J
    Gomola, I
    Izewska, J
    Huyskens, D
    Dutreix, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (07): : 1277 - 1288
  • [6] Monte Carlo physical dosimetry for small photon beams
    Perucha, M
    Sánchez-Doblado, F
    Rincón, M
    Leal, A
    Núnez, L
    Arráns, R
    Carrasco, E
    Sánchez-Calzado, JA
    Errazquin, L
    [J]. ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 555 - 559
  • [7] IAEA/WHO postal dosimetry audit methodology for electron beams using radio photoluminescent dosimeters
    Dimitriadis, Alexis
    Kazantsev, Pavel
    Chelminski, Krzysztof
    Titovich, Egor
    Naida, Ekaterina
    Magnus, Talent
    Meghzifene, Ahmed
    Azangwe, Godfrey
    Carrara, Mauro
    Swamidas, Jamema
    [J]. MEDICAL PHYSICS, 2023, 50 (11) : 7214 - 7221
  • [8] Feasibility Study For High-energy Radiotherapy Photon Beams using Radiochromic Film Postal Dosimetry Audit between Multi-institutions
    Sumida, I.
    Koizumi, M.
    Takahashi, Y.
    Ogata, T.
    Akino, Y.
    Konishi, K.
    Isohashi, F.
    Yoshioka, Y.
    Inoue, T.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S842 - S842
  • [9] Dosimetry audit for megavoltage photon beams applied in non-reference conditions
    Fadzil, Muhammad Safwan Ahmad
    Noor, Noramaliza Mohd
    Min, Ung Ngie
    Abdullah, Norhayati
    Dolah, Mohd Taufik
    Pawanchek, Mahzom
    Bradley, David Andrew
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 100 : 99 - 104
  • [10] Dosimetry quality audit of high energy photon beams in greek radiotherapy centers
    Hourdakis, Constantine J.
    Boziari, A.