Measurement of output factors for small photon beams

被引:147
|
作者
Sauer, Otto A. [1 ]
Wilbert, Juergen [1 ]
机构
[1] Univ Wurzburg, Klin Strahlentherapie, D-97080 Wurzburg, Germany
关键词
output factors; small photon beams; dosimetry; radiation detectors;
D O I
10.1118/1.2734383
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A variety of detectors and procedures for the measurement of small field output factors are discussed in the current literature. Different detectors with or without corrections are recommended. Correction factors are often derived by Monte Carlo methods, where the bias due to approximations in the model is difficult to judge. Over that, results appear to be contradictory in some cases. In this work, output factors were measured for field sizes from 4 mm up to 180 mm side length with different detectors. A simple linear correction for the energy response of solid state detectors is proposed. This led to identical values down to 8 mm field size, as long as the size of the detector is small against the field size. The correction was of the order of a few percent. For a shielded silicon diode it was well below 1%. A physically meaningful function is proposed in order to calculate output factors for arbitrary field sizes with high accuracy. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1983 / 1988
页数:6
相关论文
共 50 条
  • [1] Determination of output factors for small photon beams
    Sauer, O
    Wilbert, J
    Laqua, D
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2108 - 2108
  • [2] Verification of output factors for small photon beams using Monte Carlo methods
    Bezrukiy, NV
    DeMarco, JJ
    Chetty, I
    Smathers, JB
    Solberg, TD
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 1831 - 1833
  • [3] Effect of water tank size in measurement of output factors for 6 and 18 MV photon beams
    Zhu, JG
    Yin, FF
    Kim, JH
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1481 - 1481
  • [4] Monte-Carlo determination of output correction factors for four detectors in small MV photon beams
    Valdes Santurio, G.
    Alfonso Laguardia, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S698 - S698
  • [5] Verification of relative output factor measurement using Gafchromic films for small-field radiosurgery photon beams
    Abdullah, R.
    Sapeei, M. S.
    Shukor, N. S. A.
    Yusof, M. F. M.
    Mohamed, M.
    Idris, N. R. N.
    Yusoff, A. L.
    Zakaria, A.
    Aziz, M. Z. A.
    [J]. INTERNATIONAL NUCLEAR SCIENCE, TECHNOLOGY AND ENGINEERING CONFERENCE 2017 (INUSTEC2017), 2018, 298
  • [6] A novel method for the determination of field output factors and output correction factors for small static fields for six diodes and a microdiamond detector in megavoltage photon beams
    Casar, Bozidar
    Gershkevitsh, Eduard
    Mendez, Ignasi
    Jurkovic, Slaven
    Huq, M. Saiful
    [J]. MEDICAL PHYSICS, 2019, 46 (02) : 944 - 963
  • [7] Characterization of Exradin W1 plastic scintillator for output factors measurements in small field photon beams
    Petrucci, A.
    Consorti, R.
    Mangiacotti, F. P.
    Pressello, M. C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S744 - S744
  • [8] APPLICATION OF THE CONVOLUTION METHOD FOR CALCULATION OF OUTPUT FACTORS FOR THERAPY PHOTON BEAMS
    AHNESJO, A
    KNOOS, T
    MONTELIUS, A
    [J]. MEDICAL PHYSICS, 1992, 19 (02) : 295 - 301
  • [9] Another look at the in-air output factors for megavoltage photon beams
    Palta, J
    Liu, C
    Dempsey, J
    Ding, G
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1812 - 1812
  • [10] The Detector Characteristics for Output Factor Measurement of Small Field Electron Beams
    Wulandari, C.
    Wibowo, W. E.
    Pawiro, S. A.
    [J]. INTERNATIONAL SYMPOSIUM ON CURRENT PROGRESS IN MATHEMATICS AND SCIENCES 2016 (ISCPMS 2016), 2017, 1862