Beat-to-beat estimation of windkessel model parameters in conscious rats

被引:21
|
作者
Molino, P [1 ]
Cerutti, C [1 ]
Julien, C [1 ]
Cuisinaud, G [1 ]
Gustin, MP [1 ]
Paultre, C [1 ]
机构
[1] Fac Pharm Lyon, Dept Physiol & Clin Pharmacol, CNRS, ESA 5014, F-69373 Lyon 08, France
关键词
exponential decay time; aortic blood pressure; cardiac output;
D O I
10.1152/ajpheart.1998.274.1.H171
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A windkessel model was applied on a beat-to-beat basis to evaluate the arterial mechanical characteristics in seven conscious rats. Ascending aortic arterial pressure (AP) and blood flow were recorded during steady-state in basal conditions, during infusions of isoprenaline, sodium nitroprusside, and phenylephrine, and after intravenous atenolol injection. For each cardiac cycle the exponential decay time constant (tau) was estimated from the aortic AP curve, peripheral resistances (R) were taken as the ratio of mean AP to cardiac output, and systemic arterial compliance (C) was calculated as tau/R. In all conditions, mean correlation coefficients of the exponential regression and similar to 70% of values in each rat were >0.99, demonstrating the model validity. In all conditions t and C exhibited a large spontaneous variability over time, and beat-to-beat correlations were high between tau and C (0.83 +/- 0.03). C was increased by sodium nitroprusside, decreased by isoprenaline, but not significantly decreased by phenylephrine [5.1 +/- 0.2, 3.2 +/- 0.3, and 3.9 +/- 0.2 mu l/mmHg, respectively, vs. 4.2 +/- 0.3 mu l/mmHg (baseline)]. In conclusion, the windkessel model enables tau and C to be reliably estimated in conscious rats during spontaneous and drug-induced hemodynamic variations.
引用
收藏
页码:H171 / H177
页数:7
相关论文
共 50 条
  • [31] BEAT-TO-BEAT STABILITY OF IMPLANTED PACEMAKERS
    KRESH, YM
    PARSONNET, V
    MYERS, GH
    PARSONNET, B
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1979, 2 (03): : 297 - 304
  • [32] Recovery of beat-to-beat variations of QRS
    Lund, K
    Christiansen, EH
    Lund, B
    Pedersen, AK
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (04) : 438 - 444
  • [33] Beat-to-beat variability of QRS duration
    Hoher, M
    Ritscher, DE
    Bauer, S
    Kodler, M
    Kestler, HA
    Hombach, V
    COMPUTERS IN CARDIOLOGY 1997, VOL 24, 1997, 24 : 613 - 616
  • [34] 3 BEAT-TO-BEAT CARDIOTACHOMETER DESIGNS
    REHAK, PH
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1981, 19 (01) : 75 - 78
  • [35] BEDSIDE BEAT-TO-BEAT EJECTION FRACTION
    HOILUNDCARLSEN, PF
    MARVING, J
    JENSEN, G
    ACTA MEDICA SCANDINAVICA, 1982, : 9 - 9
  • [36] BEAT-TO-BEAT INTERVAL MEASUREMENT IN THE ELECTROCARDIOGRAM
    KOELEMAN, ASM
    ROS, HH
    VANDENAKKER, TJ
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1985, 23 (03) : 213 - 219
  • [37] Deep Learning Model with Individualized Fine-tuning for Dynamic and Beat-to-Beat Blood Pressure Estimation
    Hong, Jingyuan
    Gao, Jiasheng
    Liu, Qing
    Zhang, Yuanting
    Zheng, Yali
    2021 IEEE 17TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2021,
  • [38] Beat-to-beat cardiovascular hemodynamic parameters based on wavelet spectrogram of impedance data
    Stepanov, Rodion
    Podtaev, Sergey
    Frick, Peter
    Dumler, Andrey
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2017, 36 : 50 - 56
  • [39] BEAT-TO-BEAT HEART INTERVAL AND ARTERIAL BLOOD-PRESSURE VARIATION IN CONSCIOUS AND ANESTHETIZED DOGS
    AHONEN, E
    NEVALAINEN, T
    HARTIKAINEN, J
    HAKUMAKI, M
    ZEITSCHRIFT FUR VERSUCHSTIERKUNDE, 1985, 27 (02): : 73 - 74
  • [40] Beat-to-beat heart rate estimation fusing multimodal video and sensor data
    Antink, Christoph Hoog
    Gao, Hanno
    Brueser, Christoph
    Leonhardt, Steffen
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (08): : 2895 - 2907