Beat-to-beat heart rate estimation fusing multimodal video and sensor data

被引:29
|
作者
Antink, Christoph Hoog [1 ]
Gao, Hanno [1 ]
Brueser, Christoph [1 ]
Leonhardt, Steffen [1 ]
机构
[1] Rhein Westfal TH Aachen, Helmholtz Inst, Chair Med Informat Technol, D-52074 Aachen, Germany
来源
BIOMEDICAL OPTICS EXPRESS | 2015年 / 6卷 / 08期
关键词
NONCONTACT;
D O I
10.1364/BOE.6.002895
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Coverage and accuracy of unobtrusively measured biosignals are generally relatively low compared to clinical modalities. This can be improved by exploiting redundancies in multiple channels with methods of sensor fusion. In this paper, we demonstrate that two modalities, skin color variation and head motion, can be extracted from the video stream recorded with a webcam. Using a Bayesian approach, these signals are fused with a ballistocardiographic signal obtained from the seat of a chair with a mean absolute beat-to-beat estimation error below 25 milliseconds and an average coverage above 90% compared to an ECG reference.
引用
收藏
页码:2895 / 2907
页数:13
相关论文
共 50 条
  • [1] Adaptive Beat-to-Beat Heart Rate Estimation in Ballistocardiograms
    Brueser, Christoph
    Stadlthanner, Kurt
    de Waele, Stijn
    Leonhardt, Steffen
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2011, 15 (05): : 778 - 786
  • [2] Detection of heart beats in multimodal data: a robust beat-to-beat interval estimation approach
    Antink, Christoph Hoog
    Brueser, Christoph
    Leonhardt, Steffen
    [J]. PHYSIOLOGICAL MEASUREMENT, 2015, 36 (08) : 1679 - 1690
  • [3] A BEAT-TO-BEAT HEART-RATE METER
    NIJHAWAN, SC
    SHARMA, VK
    KHANDPUR, RS
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (01) : 42 - 44
  • [4] Beat-to-beat heart rate detection by smartphone accelerometers
    Landreani, F.
    Martin-Yebra, A.
    Casellato, C.
    Frigo, C.
    Pavan, E.
    Migeotte, P. -F.
    Caiani, E. G.
    [J]. EUROPEAN HEART JOURNAL, 2016, 37 : 859 - 860
  • [5] DIGITAL BEAT-TO-BEAT HEART-RATE METER
    VOULGARIS, NC
    BAILAS, AA
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1984, 22 (02) : 181 - 183
  • [6] Beat-to-beat adaptation of QT interval to heart rate
    Pueyo, Esther
    Malik, Marek
    Laguna, Pablo
    [J]. 2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 2475 - 2478
  • [7] Beat-to-Beat Cardiac Pulse Rate Measurement From Video
    Hill, Brian L.
    Liu, Xin
    McDuff, Daniel
    [J]. 2021 IEEE/CVF INTERNATIONAL CONFERENCE ON COMPUTER VISION WORKSHOPS (ICCVW 2021), 2021, : 2739 - 2742
  • [8] Assessment of beat-to-beat heart rate detection method using a camera as contactless sensor
    Iozzia, L.
    Cerina, L.
    Mainardi, L. T.
    [J]. 2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 521 - 524
  • [9] Unconstrained Accurate Beat-to-beat Heart Rate Extraction Based on Piezoelectric Ceramics Sensor
    Fang Zhen
    Bai Zhongrui
    Chen Xianxiang
    Xia Pan
    He Zhengling
    Zhao Rongjian
    [J]. JOURNAL OF ELECTRONICS & INFORMATION TECHNOLOGY, 2021, 43 (05) : 1472 - 1479
  • [10] Heart Rate Estimation on a Beat-to-Beat Basis via Ballistocardiography - A hybrid Approach.
    Friedrich, David
    Aubert, Xavier L.
    Fuehr, Hartmut
    Brauers, Andreas
    [J]. 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 4048 - 4051