Beat-to-beat estimation of windkessel model parameters in conscious rats

被引:21
|
作者
Molino, P [1 ]
Cerutti, C [1 ]
Julien, C [1 ]
Cuisinaud, G [1 ]
Gustin, MP [1 ]
Paultre, C [1 ]
机构
[1] Fac Pharm Lyon, Dept Physiol & Clin Pharmacol, CNRS, ESA 5014, F-69373 Lyon 08, France
关键词
exponential decay time; aortic blood pressure; cardiac output;
D O I
10.1152/ajpheart.1998.274.1.H171
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A windkessel model was applied on a beat-to-beat basis to evaluate the arterial mechanical characteristics in seven conscious rats. Ascending aortic arterial pressure (AP) and blood flow were recorded during steady-state in basal conditions, during infusions of isoprenaline, sodium nitroprusside, and phenylephrine, and after intravenous atenolol injection. For each cardiac cycle the exponential decay time constant (tau) was estimated from the aortic AP curve, peripheral resistances (R) were taken as the ratio of mean AP to cardiac output, and systemic arterial compliance (C) was calculated as tau/R. In all conditions, mean correlation coefficients of the exponential regression and similar to 70% of values in each rat were >0.99, demonstrating the model validity. In all conditions t and C exhibited a large spontaneous variability over time, and beat-to-beat correlations were high between tau and C (0.83 +/- 0.03). C was increased by sodium nitroprusside, decreased by isoprenaline, but not significantly decreased by phenylephrine [5.1 +/- 0.2, 3.2 +/- 0.3, and 3.9 +/- 0.2 mu l/mmHg, respectively, vs. 4.2 +/- 0.3 mu l/mmHg (baseline)]. In conclusion, the windkessel model enables tau and C to be reliably estimated in conscious rats during spontaneous and drug-induced hemodynamic variations.
引用
收藏
页码:H171 / H177
页数:7
相关论文
共 50 条
  • [41] SPECTRAL-ANALYSIS OF THE EFFECTS OF KETANSERIN ON BEAT-TO-BEAT CARDIOVASCULAR PARAMETERS IN HUMANS
    KINGMA, R
    SCHEFFER, GJ
    TENVOORDE, B
    WESSELING, K
    DELANGE, J
    BRITISH JOURNAL OF ANAESTHESIA, 1994, 72 : 32 - 32
  • [42] BEAT-TO-BEAT ESTIMATION OF PERIPHERAL RESISTANCE AND ARTERIAL COMPLIANCE DURING PRESSURE TRANSIENTS
    TOOROP, GP
    WESTERHOF, N
    ELZINGA, G
    AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 252 (06): : H1275 - H1283
  • [43] Model for the respiratory modulation of the heart beat-to-beat time interval series
    Capurro, A
    Diambra, L
    Malta, CP
    PHYSICA A-STATISTICAL MECHANICS AND ITS APPLICATIONS, 2005, 355 (2-4) : 439 - 460
  • [44] Beat-to-Beat Oscillometric Blood Pressure Estimation: A Bayesian Approach With System Identification
    Farzam, Ramin
    Azad, Mohammad Hasan
    Moghaddam, Hamid Abrishami
    Forouzanfar, Mohamad
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2025, 72 (02) : 619 - 629
  • [45] An elastic manifold learning approach to beat-to-beat interval estimation with ballistocardiography signals
    Shen, Gang
    Ding, Ruidong
    Yang, Mingqi
    Han, Dan
    Zhang, Biyong
    ADVANCED ENGINEERING INFORMATICS, 2020, 44
  • [46] The processing of beat-to-beat time intervals by multipoles
    Lewkowicz, M
    Levitan, J
    Saermark, K
    Thomsen, PEB
    MODELLING AND CONTROL IN BIOMEDICAL SYSTEMS 2003 (INCLUDING BIOLOGICAL SYSTEMS), 2003, : 199 - 202
  • [47] A BEAT-TO-BEAT HEART-RATE METER
    NIJHAWAN, SC
    SHARMA, VK
    KHANDPUR, RS
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (01) : 42 - 44
  • [48] Beat-to-beat variability of pulse wave velocity
    Svacinova, J.
    Hidegova, S.
    Sieglova, H.
    Kascakova, Z.
    Fabsik, M.
    Jakubik, J.
    Novak, J.
    Novakova, Z.
    Hruskova, H.
    ACTA PHYSIOLOGICA, 2019, 227 : 161 - 161
  • [49] A CARDIOTACHOMETER WITH LINEAR INDICATION OF BEAT-TO-BEAT FREQUENCY
    POPE, JM
    DEBOO, GJ
    SMITH, DBD
    PSYCHOPHYSIOLOGY, 1968, 4 (04) : 486 - &
  • [50] COMPARISON OF 4 BEAT-TO-BEAT CARDIOTACHOMETER DESIGNS
    MASON, CA
    SHOUP, JF
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1979, 17 (03) : 349 - 359