Application of dose kernel calculation using a simplified Monte Carlo method to treatment plan for scanned proton beams

被引:1
|
作者
Mizutani, Shohei [1 ]
Takada, Yoshihisa [1 ]
Kohno, Ryosuke [2 ]
Hotta, Kenji [2 ]
Tansho, Ryohei [1 ]
Akimoto, Tetsuo [2 ]
机构
[1] Univ Tsukuba, Grad Sch Pure & Appl Sci, Tsukuba, Ibaraki, Japan
[2] Natl Canc Ctr Hosp East, Res Ctr Innovat Oncol, Particle Therapy Div, Chiba, Japan
来源
关键词
dose kernel calculation; simplified Monte Carlo method; treatment planning system; nasopharyngeal tumor case; proton pencil beam scanning; PARTICLE THERAPY; CLINICAL IMPLEMENTATION; SYSTEM; IRRADIATION; ALGORITHM; ACCURACY;
D O I
10.1120/jacmp.v17i2.5747
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Full Monte Carlo (FMC) calculation of dose distribution has been recognized to have superior accuracy, compared with the pencil beam algorithm (PBA). However, since the FMC methods require long calculation time, it is difficult to apply them to routine treatment planning at present. In order to improve the situation, a simplified Monte Carlo (SMC) method has been introduced to the dose kernel calculation applicable to dose optimization procedure for the proton pencil beam scanning. We have evaluated accuracy of the SMC calculation by comparing a result of the dose kernel calculation using the SMC method with that using the FMC method in an inhomogeneous phantom. The dose distribution obtained by the SMC method was in good agreement with that obtained by the FMC method. To assess the usefulness of SMC calculation in clinical situations, we have compared results of the dose calculation using the SMC with those using the PBA method for three clinical cases of tumor treatment. The dose distributions calculated with the PBA dose kernels appear to be homogeneous in the planning target volumes (PTVs). In practice, the dose distributions calculated with the SMC dose kernels with the spot weights optimized with the PBA method show largely inhomogeneous dose distributions in the PTVs, while those with the spot weights optimized with the SMC method have moderately homogeneous distributions in the PTVs. Calculation using the SMC method is faster than that using the GEANT4 by three orders of magnitude. In addition, the graphic processing unit (GPU) boosts the calculation speed by 13 times for the treatment planning using the SMC method. Thence, the SMC method will be applicable to routine clinical treatment planning for reproduction of the complex dose distribution more accurately than the PBA method in a reasonably short time by use of the GPU-based calculation engine.
引用
收藏
页码:315 / 327
页数:13
相关论文
共 50 条
  • [31] Macro Monte Carlo for Proton Dose Calculation in Different Materials
    Fix, M. K.
    Frei, D.
    Volken, W.
    Born, E. J.
    Aebersold, D.
    Manser, P.
    MEDICAL PHYSICS, 2012, 39 (06) : 3873 - 3873
  • [32] Fast Monte Carlo Dose Calculation on GPU for Proton Therapy
    Jia, X.
    Schuemann, J.
    Paganetti, H.
    Jiang, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S841 - S841
  • [33] Commissioning and clinical implementation of an independent dose calculation system for scanned proton beams
    Dreindl, Ralf
    Bolsa-Ferruz, Marta
    Fayos-Sola, Rosa
    Cabal, Fatima Padilla
    Scheuchenpflug, Lukas
    Elia, Alessio
    Amico, Antonio
    Carlino, Antonio
    Stock, Markus
    Grevillot, Loic
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (05):
  • [34] Monte Carlo dose calculation improvements for low energy electron beams using eMC
    Fix, Michael K.
    Frei, Daniel
    Volken, Werner
    Neuenschwander, Hans
    Born, Ernst J.
    Manser, Peter
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (16): : 4577 - 4588
  • [35] A simplified methodology to produce Monte Carlo dose distributions in proton therapy
    Beltran, Chris
    Jia, Yingcui
    Slopsema, Roelf
    Yeung, Daniel
    Li, Zuofeng
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (04): : 2 - 10
  • [36] Towards clinical Monte Carlo treatment planning for photon beams: Swiss Monte Carlo plan
    Figini, SP
    Fix, MK
    Manser, P
    Bom, EJ
    Frei, D
    Volken, W
    Neuenschwander, H
    Niederer, P
    Mini, R
    MEDICAL PHYSICS, 2003, 30 (06) : 1516 - 1516
  • [37] Verification of Proton Treatment Dose Calculation and Delivery using Monte Carlo Simulated Dose and Isotope Distribution and Measured Isotope Distribution
    Kirk, M. L.
    Teo, B.
    Dolney, D.
    McDonough, J. E.
    Tochner, Z.
    Lin, A.
    Lin, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S154 - S154
  • [38] Application of the Monte Carlo method to pressure calculation
    Suetsugu, Y
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1996, 14 (01): : 245 - 250
  • [40] A simplified Monte Carlo algorithm considering large-angle scattering for fast and accurate calculation of proton dose
    Takayanagi, Taisuke
    Hirayama, Shusuke
    Fujitaka, Shinichiro
    Fujimoto, Rintaro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (01): : 60 - 72