Application of dose kernel calculation using a simplified Monte Carlo method to treatment plan for scanned proton beams

被引:1
|
作者
Mizutani, Shohei [1 ]
Takada, Yoshihisa [1 ]
Kohno, Ryosuke [2 ]
Hotta, Kenji [2 ]
Tansho, Ryohei [1 ]
Akimoto, Tetsuo [2 ]
机构
[1] Univ Tsukuba, Grad Sch Pure & Appl Sci, Tsukuba, Ibaraki, Japan
[2] Natl Canc Ctr Hosp East, Res Ctr Innovat Oncol, Particle Therapy Div, Chiba, Japan
来源
关键词
dose kernel calculation; simplified Monte Carlo method; treatment planning system; nasopharyngeal tumor case; proton pencil beam scanning; PARTICLE THERAPY; CLINICAL IMPLEMENTATION; SYSTEM; IRRADIATION; ALGORITHM; ACCURACY;
D O I
10.1120/jacmp.v17i2.5747
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Full Monte Carlo (FMC) calculation of dose distribution has been recognized to have superior accuracy, compared with the pencil beam algorithm (PBA). However, since the FMC methods require long calculation time, it is difficult to apply them to routine treatment planning at present. In order to improve the situation, a simplified Monte Carlo (SMC) method has been introduced to the dose kernel calculation applicable to dose optimization procedure for the proton pencil beam scanning. We have evaluated accuracy of the SMC calculation by comparing a result of the dose kernel calculation using the SMC method with that using the FMC method in an inhomogeneous phantom. The dose distribution obtained by the SMC method was in good agreement with that obtained by the FMC method. To assess the usefulness of SMC calculation in clinical situations, we have compared results of the dose calculation using the SMC with those using the PBA method for three clinical cases of tumor treatment. The dose distributions calculated with the PBA dose kernels appear to be homogeneous in the planning target volumes (PTVs). In practice, the dose distributions calculated with the SMC dose kernels with the spot weights optimized with the PBA method show largely inhomogeneous dose distributions in the PTVs, while those with the spot weights optimized with the SMC method have moderately homogeneous distributions in the PTVs. Calculation using the SMC method is faster than that using the GEANT4 by three orders of magnitude. In addition, the graphic processing unit (GPU) boosts the calculation speed by 13 times for the treatment planning using the SMC method. Thence, the SMC method will be applicable to routine clinical treatment planning for reproduction of the complex dose distribution more accurately than the PBA method in a reasonably short time by use of the GPU-based calculation engine.
引用
收藏
页码:315 / 327
页数:13
相关论文
共 50 条
  • [41] Is Monte Carlo Dose Calculation Method Necessary for Cyberknife Brain Treatment Planning?
    Wang, L.
    Fourkal, E.
    Hayes, S.
    Jin, L.
    Ma, C.
    MEDICAL PHYSICS, 2014, 41 (06) : 275 - +
  • [42] Evaluation of the Monte Carlo Dose Calculation Engine of Eclipse Treatment Planning System for Electron Beams
    Kamta, G. Lagmago
    Reniers, B.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [43] Full forward Monte Carlo calculation of portal dose from MLC collimated treatment beams
    Spezi, E
    Lewis, DG
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (03): : 377 - 390
  • [44] Evaluation of an electron Monte Carlo dose calculation algorithm for electron beams
    Hu, Ye Angela
    Song, Haijun
    Chen, Zhe
    Zhou, Sumin
    Yin, Fang-Fang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2008, 9 (03): : 1 - 15
  • [45] A Monte Carlo Dose Calculation Framework for Electron Beams On Varian TrueBeam
    Rodrigues, A.
    Sawkey, D.
    Yin, F.
    Wu, Q.
    MEDICAL PHYSICS, 2014, 41 (06) : 314 - +
  • [46] Optimizing portal dose calculation for an amorphous silicon detector using Swiss Monte Carlo Plan
    Frauchiger, D.
    Fix, M. K.
    Frei, D.
    Volken, W.
    Mini, R.
    Manser, P.
    FIRST EUROPEAN WORKSHOP ON MONTE CARLO TREATMENT PLANNING, 2007, 74
  • [47] A Novel Component Method to Delineate Surgical Spine Implants for Proton Monte Carlo Dose Calculation
    Chang, C.
    Charyyev, S.
    Harms, J.
    Slopsema, R.
    Wolf, J.
    Refai, D.
    Yoon, T.
    McDonald, M.
    Bradley, J.
    Leng, S.
    Zhou, J.
    Yang, X.
    Lin, L.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [48] Peregrine Monte Carlo dose calculations for radiotherapy using clinically realistic neutron and proton beams
    Cox, LJ
    Bohm, TD
    Chadwick, MB
    DeLuca, PM
    Siebers, JV
    INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, VOL 59, PT 1 AND 2, 1997, 59 : 1693 - 1699
  • [49] Improved Electron Monte Carlo Dose Calculation for Low Energy Electron Beams Using EMC
    Fix, M. K.
    Frei, D.
    Volken, W.
    Neuenschwander, H.
    Born, E. J.
    Manser, P.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [50] Advanced kernel methods vs. Monte Carlo-based dose calculation for high energy photon beams
    Fotina, Irina
    Winkler, Peter
    Kuenzler, Thomas
    Reiterer, Jochen
    Simmat, Isabell
    Georg, Dietmar
    RADIOTHERAPY AND ONCOLOGY, 2009, 93 (03) : 645 - 653