Exploring Interdigitated Electrode Arrays Screen-Printed on Paper Substrates for Steady-State Electrochemical Measurements

被引:0
|
作者
Yevenes, C. F. Guajardo [1 ,2 ,7 ]
Wongkaew, N. [3 ]
Ngamchana, S. [4 ,7 ]
Surareungchai, W. [5 ,6 ,7 ]
机构
[1] KMUTT, Biol Engn Program, Fac Engn, Bangkok, Thailand
[2] KMUTT, Pilot Plant Dev & Training Inst, Bangkok, Thailand
[3] Univ Regenburg, Inst Analyt Chem Chemo & Biosensors, Univ Str 31, D-93053 Regensburg, Germany
[4] KMUTT Bang Khun Thian, Natl Sci & Technol Dev Agcy, Natl Ctr Genet Engn & Biotechnol, Biochem Engn & Syst Biol Res Grp,Biosci & Syst Bi, Bangkok, Thailand
[5] KMUTT, Nanosci & Nanotechnol Grad Program, Bangkok, Thailand
[6] KMUTT, Sch Bioresources & Technol, Bangkok, Thailand
[7] King Mongkuts Univ Technol Thonburi KMUTT, 49 Soi Thian Thale 25, Bangkok 10150, Thailand
关键词
Electroanalytical Electrochemistry; Electrochemical Engineering; Sensors; Theory and Modelling; ANALYTICAL DEVICES; BIOSENSORS; DOPAMINE; MEDIA;
D O I
10.1149/1945-7111/ac992b
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This research explores the use of interdigitated electrode arrays (IDE) screen-printed on paper substrate for electrochemical measurements in steady state. Since the steady state is strongly related to IDE dimensions, the accuracy and reproducibility of the fabrication process were assessed for stencils of 120- and 200-mesh. Simulations were used to predict the limiting current and time response, and as a benchmark for comparison with the experimental results. For accurate an comparison, evaporation was prevented by using a homemade humidity box, which enabled measurements for periods as long as 30 min. Although cyclic voltammetry measurements in steady state were possible, this required at least 15 min per cycle when using the smallest electrodes (band width of 0.205 mm). Chronoamperometric measurements reaching steady state were also possible, requiring nearly 5 min for the largest electrodes (band width of 0.376 mm). Regarding the reproducibility of measurements, the relative standard deviations (RSD) of current and response time were near 12% and 26%, respectively. We attribute this mainly to the reproducibility of IDE fabrication (8% RSD). Experimental currents were approximately 30% to 34% of their simulated counterparts. Conversely, the simulated response times were about 30% to 50% of their experimental counterparts. We ascribe these discrepancies to the porosity of the paper (Whatman 2 CHR), estimated to be near 31% under wet conditions. This suggests that fibers inside the paper substrate block the passage of electrochemical species, thereby delaying their diffusion and decreasing the current. (C) 2022 The Author(s). Published on behalf of The Electrochemical Society by IOP Publishing Limited.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] SCREEN-PRINTED ULTRAMICROELECTRODE ARRAYS FOR ON-SITE STRIPPING MEASUREMENTS OF TRACE-METALS
    WANG, J
    LU, JM
    TIAN, BM
    YARNITZKY, C
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 361 (1-2): : 77 - 83
  • [42] Nanosilver and Graphene Oxide Modified Screen-Printed Carbon Electrode for Electrochemical Detection of Bisphenol A
    Wan, H.
    Xie, X.
    Liu, H.
    Mahmud, S.
    [J]. Journal of Analytical Chemistry, 1600, 79 (11): : 1640 - 1648
  • [43] An electrochemical sensor based on a clay-coated screen-printed electrode for the determination of arbutin
    Shih, Y
    Zen, JM
    [J]. ANALYTICA CHIMICA ACTA, 2000, 412 (1-2) : 63 - 68
  • [44] Simple and rapid electrochemical detection of 1-benzylpiperazine on carbon screen-printed electrode
    Rocha, G. Raquel
    Silva, C. O. F. Isabella
    Arantes, C. Luciano
    Stefano, S. Jessica
    Lima, D. Camila
    Melo, M. A. Larissa
    Munoz, A. A. Rodrigo
    dos Santos, T. P. Wallans
    Richter, M. Eduardo
    [J]. MICROCHEMICAL JOURNAL, 2021, 167
  • [45] Electrochemical Synthesis of Polyaniline Films at a Screen-printed Carbon Electrode and their Potential Applicability in Biosensing
    Stoces, Matej
    Kalcher, Kurt
    Svancara, Ivan
    Vytras, Karel
    [J]. MODERN ELECTROCHEMICAL METHODS XXX, 2010, : 158 - 162
  • [46] Sensitive Electrochemical Detection of Creatinine at Disposable Screen-Printed Carbon Electrode Mixed with Ferrocenemethanol
    Chen, Ping
    Peng, Yong
    He, Min
    Yan, Xin-Chuang
    Zhang, Yuan
    Liu, You-Nian
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (07): : 8931 - 8939
  • [47] A Novel Electrochemical Sensor for Epinephrine in the Presence of Acetylcholine Based on Modified Screen-Printed Electrode
    Mohammadi, Sayed Zia
    Mosazadeh, Farideh
    Beitollah, Hadis
    Barani, Zohreh
    [J]. RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2022, 58 (04) : 248 - 257
  • [48] Modified Screen Printed Electrode Suitable for Electrochemical Measurements in Gas Phase
    Toniolo, Rosanna
    Dossi, Nicolo
    Giannilivigni, Emanuele
    Fattori, Andrea
    Svigelj, Rossella
    Bontempelli, Gino
    Giacomino, Agnese
    Daniele, Salvatore
    [J]. ANALYTICAL CHEMISTRY, 2020, 92 (05) : 3689 - 3696
  • [49] Screen-printed carbon electrode-based electrochemical immunosensor for rapid detection of microalbuminuria
    Tsai, Jang-Zern
    Chen, Ching-Jung
    Settu, Kalpana
    Lin, Yu-Feng
    Chen, Chien-Lung
    Liu, Jen-Tsai
    [J]. BIOSENSORS & BIOELECTRONICS, 2016, 77 : 1175 - 1182
  • [50] Disposable paper-based electrochemical sensor utilizing inkjet-printed Polyaniline modified screen-printed carbon electrode for Ascorbic acid detection
    Kit-Anan, Worrapong
    Olarnwanich, Aricha
    Sriprachuabwong, Chakrit
    Karuwan, Chanpen
    Tuantranont, Adisorn
    Wisitsoraat, Anurat
    Srituravanich, Werayut
    Pimpin, Alongkorn
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 685 : 72 - 78