Exploring Interdigitated Electrode Arrays Screen-Printed on Paper Substrates for Steady-State Electrochemical Measurements

被引:0
|
作者
Yevenes, C. F. Guajardo [1 ,2 ,7 ]
Wongkaew, N. [3 ]
Ngamchana, S. [4 ,7 ]
Surareungchai, W. [5 ,6 ,7 ]
机构
[1] KMUTT, Biol Engn Program, Fac Engn, Bangkok, Thailand
[2] KMUTT, Pilot Plant Dev & Training Inst, Bangkok, Thailand
[3] Univ Regenburg, Inst Analyt Chem Chemo & Biosensors, Univ Str 31, D-93053 Regensburg, Germany
[4] KMUTT Bang Khun Thian, Natl Sci & Technol Dev Agcy, Natl Ctr Genet Engn & Biotechnol, Biochem Engn & Syst Biol Res Grp,Biosci & Syst Bi, Bangkok, Thailand
[5] KMUTT, Nanosci & Nanotechnol Grad Program, Bangkok, Thailand
[6] KMUTT, Sch Bioresources & Technol, Bangkok, Thailand
[7] King Mongkuts Univ Technol Thonburi KMUTT, 49 Soi Thian Thale 25, Bangkok 10150, Thailand
关键词
Electroanalytical Electrochemistry; Electrochemical Engineering; Sensors; Theory and Modelling; ANALYTICAL DEVICES; BIOSENSORS; DOPAMINE; MEDIA;
D O I
10.1149/1945-7111/ac992b
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This research explores the use of interdigitated electrode arrays (IDE) screen-printed on paper substrate for electrochemical measurements in steady state. Since the steady state is strongly related to IDE dimensions, the accuracy and reproducibility of the fabrication process were assessed for stencils of 120- and 200-mesh. Simulations were used to predict the limiting current and time response, and as a benchmark for comparison with the experimental results. For accurate an comparison, evaporation was prevented by using a homemade humidity box, which enabled measurements for periods as long as 30 min. Although cyclic voltammetry measurements in steady state were possible, this required at least 15 min per cycle when using the smallest electrodes (band width of 0.205 mm). Chronoamperometric measurements reaching steady state were also possible, requiring nearly 5 min for the largest electrodes (band width of 0.376 mm). Regarding the reproducibility of measurements, the relative standard deviations (RSD) of current and response time were near 12% and 26%, respectively. We attribute this mainly to the reproducibility of IDE fabrication (8% RSD). Experimental currents were approximately 30% to 34% of their simulated counterparts. Conversely, the simulated response times were about 30% to 50% of their experimental counterparts. We ascribe these discrepancies to the porosity of the paper (Whatman 2 CHR), estimated to be near 31% under wet conditions. This suggests that fibers inside the paper substrate block the passage of electrochemical species, thereby delaying their diffusion and decreasing the current. (C) 2022 The Author(s). Published on behalf of The Electrochemical Society by IOP Publishing Limited.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Electrochemical characterization of some commercial screen-printed electrodes in different redox substrates
    Mistry, Kalyan Kumar
    Deepthy, Sagarika T.
    Chaudhuri, Chirasree Roy
    Saha, Hiranmay
    [J]. CURRENT SCIENCE, 2015, 109 (08): : 1427 - 1436
  • [22] Disposable Screen-printed Bismuth Electrode Modified with Multi-walled Carbon Nanotubes for Electrochemical Stripping Measurements
    Xiangheng Niu
    Hongli Zhao
    Minbo Lan
    [J]. Analytical Sciences, 2011, 27 : 1237 - 1241
  • [23] Quantification of Myoinositol in Serum by Electrochemical Detection with an Unmodified Screen-Printed Carbon Electrode
    Jin, Xinrui
    Zhao, Yuanqing
    Gu, Xiujuan
    Zhong, Min
    Kong, Xin
    Li, Guangrong
    Tian, Gang
    Liu, Jinbo
    [J]. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2022, 2022
  • [24] Disposable Screen-printed Bismuth Electrode Modified with Multi-walled Carbon Nanotubes for Electrochemical Stripping Measurements
    Niu, Xiangheng
    Zhao, Hongli
    Lan, Minbo
    [J]. ANALYTICAL SCIENCES, 2011, 27 (12) : 1237 - 1241
  • [25] Electrochemical Detection of Tributyrin using Gold Nanoparticle Functionalized Screen-Printed Electrode
    Aidil, A.
    Balakrishnan, S. R.
    Zanariah, C. W.
    Ismail, W. Z. Wan
    Sahrim, M.
    Ismail, I.
    Jamaludin, J.
    [J]. 19TH IEEE STUDENT CONFERENCE ON RESEARCH AND DEVELOPMENT (SCORED 2021), 2021, : 47 - 51
  • [26] Sensitive electrochemical detection of L-Cysteine at a screen-printed diamond electrode
    Matsunaga, Tomohiro
    Kondo, Takeshi
    Shitanda, Isao
    Hoshi, Yoshinao
    Itagaki, Masayuki
    Tojo, Toshifumi
    Yuasa, Makoto
    [J]. CARBON, 2021, 173 : 395 - 402
  • [27] ELECTROCHEMICAL DETERMINATION OF METHOTREXATE AT A DISPOSABLE SCREEN-PRINTED ELECTRODE AND ITS APPLICATION STUDIES
    Wang, Shi
    Qi, Zheqiong
    Huang, Hongke
    Ding, Hong
    [J]. ANALYTICAL LETTERS, 2012, 45 (12) : 1658 - 1669
  • [28] Electrochemical sensing of Sudan I using the modified graphite screen-printed electrode
    Tajik, Somayeh
    Beitollahi, Hadi
    Nejad, Fariba Garkani
    Safaei, Mohadeseh
    Jahani, Peyman Mohammadzadeh
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2022, 102 (07) : 1477 - 1490
  • [29] Sensitive electrochemical detection of horseradish peroxidase at disposable screen-printed carbon electrode
    Lee, Ai-Cheng
    Liu, Guodong
    Heng, Chew-Kiat
    Tan, Swee-Ngin
    Lim, Tit-Meng
    Lin, Yuehe
    [J]. ELECTROANALYSIS, 2008, 20 (18) : 2040 - 2046
  • [30] Moxifloxacin Hydrochloride Electrochemical Detection at Gold Nanoparticles Modified Screen-Printed Electrode
    Shehata, M.
    Fekry, Amany M.
    Walcarius, Alain
    [J]. SENSORS, 2020, 20 (10)