Exploring Interdigitated Electrode Arrays Screen-Printed on Paper Substrates for Steady-State Electrochemical Measurements

被引:0
|
作者
Yevenes, C. F. Guajardo [1 ,2 ,7 ]
Wongkaew, N. [3 ]
Ngamchana, S. [4 ,7 ]
Surareungchai, W. [5 ,6 ,7 ]
机构
[1] KMUTT, Biol Engn Program, Fac Engn, Bangkok, Thailand
[2] KMUTT, Pilot Plant Dev & Training Inst, Bangkok, Thailand
[3] Univ Regenburg, Inst Analyt Chem Chemo & Biosensors, Univ Str 31, D-93053 Regensburg, Germany
[4] KMUTT Bang Khun Thian, Natl Sci & Technol Dev Agcy, Natl Ctr Genet Engn & Biotechnol, Biochem Engn & Syst Biol Res Grp,Biosci & Syst Bi, Bangkok, Thailand
[5] KMUTT, Nanosci & Nanotechnol Grad Program, Bangkok, Thailand
[6] KMUTT, Sch Bioresources & Technol, Bangkok, Thailand
[7] King Mongkuts Univ Technol Thonburi KMUTT, 49 Soi Thian Thale 25, Bangkok 10150, Thailand
关键词
Electroanalytical Electrochemistry; Electrochemical Engineering; Sensors; Theory and Modelling; ANALYTICAL DEVICES; BIOSENSORS; DOPAMINE; MEDIA;
D O I
10.1149/1945-7111/ac992b
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This research explores the use of interdigitated electrode arrays (IDE) screen-printed on paper substrate for electrochemical measurements in steady state. Since the steady state is strongly related to IDE dimensions, the accuracy and reproducibility of the fabrication process were assessed for stencils of 120- and 200-mesh. Simulations were used to predict the limiting current and time response, and as a benchmark for comparison with the experimental results. For accurate an comparison, evaporation was prevented by using a homemade humidity box, which enabled measurements for periods as long as 30 min. Although cyclic voltammetry measurements in steady state were possible, this required at least 15 min per cycle when using the smallest electrodes (band width of 0.205 mm). Chronoamperometric measurements reaching steady state were also possible, requiring nearly 5 min for the largest electrodes (band width of 0.376 mm). Regarding the reproducibility of measurements, the relative standard deviations (RSD) of current and response time were near 12% and 26%, respectively. We attribute this mainly to the reproducibility of IDE fabrication (8% RSD). Experimental currents were approximately 30% to 34% of their simulated counterparts. Conversely, the simulated response times were about 30% to 50% of their experimental counterparts. We ascribe these discrepancies to the porosity of the paper (Whatman 2 CHR), estimated to be near 31% under wet conditions. This suggests that fibers inside the paper substrate block the passage of electrochemical species, thereby delaying their diffusion and decreasing the current. (C) 2022 The Author(s). Published on behalf of The Electrochemical Society by IOP Publishing Limited.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] STEADY-STATE MEASUREMENTS OF RESPIRATION RATE WITH AN OXYGEN ELECTRODE
    TJEPKEMA, JD
    YOCUM, CS
    [J]. ANALYTICAL BIOCHEMISTRY, 1975, 63 (02) : 341 - 344
  • [32] Development of aptasensor for chlorpyrifos detection using paper-based screen-printed electrode
    Himanshu, Jayendra Kumar
    Lakshmi, G. B. V. S.
    Verma, Awadhesh Kumar
    Ahlawat, Amit
    Solanki, Pratima R.
    [J]. ENVIRONMENTAL RESEARCH, 2024, 240
  • [33] Electrochemical characterisation of novel screen-printed carbon paste electrodes for voltammetric measurements
    Sys, Milan
    Khaled, Elmorsy
    Metelka, Radovan
    Vytras, Karel
    [J]. JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2017, 82 (7-8) : 865 - 877
  • [34] Innovative screen-printed electrodes on cork composite substrates applied to sulfadiazine electrochemical sensing
    Tavares, Ana P. M.
    de Sa, M. Helena
    Sales, M. Goreti F.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 880
  • [35] Paper microfluidics on screen-printed electrodes for simple electrochemical magneto-immunosensor performance
    Ruiz-Vega, Gisela
    Garcia-Berrocoso, Teresa
    Montaner, Joan
    Baldrich, Eva
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2019, 298
  • [36] Novel reagentless paper-based screen-printed electrochemical sensor to detect phosphate
    Cinti, Stefano
    Talarico, Daria
    Palleschi, Giuseppe
    Moscone, Danila
    Arduini, Fabiana
    [J]. ANALYTICA CHIMICA ACTA, 2016, 919 : 78 - 84
  • [37] Soldering surface mount components on screen-printed Ag patterns on paper and polyimide substrates for hybrid printed electronics
    Li, Xiaotian
    Andersson, Henrik
    Siden, Johan
    Schon, Thomas
    [J]. FLEXIBLE AND PRINTED ELECTRONICS, 2018, 3 (01):
  • [38] SCREEN-PRINTED ELECTRODES MADE ON STONE PAPER SUBSTRATE FOR URIC ACID ELECTROCHEMICAL DETECTION
    Varodi, Codruta
    Pogacean, Florina
    Gheorghe, Marin
    Barbu-Tudoran, Lucian
    Pruneanu, Stela
    [J]. STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA, 2020, 65 (02): : 233 - 242
  • [39] Efficient separation and quantitative detection of Listeria monocytogenes based on screen-printed interdigitated electrode, urease and magnetic nanoparticles
    Wang, Dan
    Chen, Qi
    Huo, Huiling
    Bai, Shanshan
    Cai, Gaozhe
    Lai, Weihua
    Lin, Jianhan
    [J]. FOOD CONTROL, 2017, 73 : 555 - 561
  • [40] A Novel Electrochemical Sensor for Epinephrine in the Presence of Acetylcholine Based on Modified Screen-Printed Electrode
    Farideh Sayed Zia Mohammadi
    Hadis Mosazadeh
    Zohreh Beitollah
    [J]. Russian Journal of Electrochemistry, 2022, 58 : 248 - 257