Exploring Interdigitated Electrode Arrays Screen-Printed on Paper Substrates for Steady-State Electrochemical Measurements

被引:0
|
作者
Yevenes, C. F. Guajardo [1 ,2 ,7 ]
Wongkaew, N. [3 ]
Ngamchana, S. [4 ,7 ]
Surareungchai, W. [5 ,6 ,7 ]
机构
[1] KMUTT, Biol Engn Program, Fac Engn, Bangkok, Thailand
[2] KMUTT, Pilot Plant Dev & Training Inst, Bangkok, Thailand
[3] Univ Regenburg, Inst Analyt Chem Chemo & Biosensors, Univ Str 31, D-93053 Regensburg, Germany
[4] KMUTT Bang Khun Thian, Natl Sci & Technol Dev Agcy, Natl Ctr Genet Engn & Biotechnol, Biochem Engn & Syst Biol Res Grp,Biosci & Syst Bi, Bangkok, Thailand
[5] KMUTT, Nanosci & Nanotechnol Grad Program, Bangkok, Thailand
[6] KMUTT, Sch Bioresources & Technol, Bangkok, Thailand
[7] King Mongkuts Univ Technol Thonburi KMUTT, 49 Soi Thian Thale 25, Bangkok 10150, Thailand
关键词
Electroanalytical Electrochemistry; Electrochemical Engineering; Sensors; Theory and Modelling; ANALYTICAL DEVICES; BIOSENSORS; DOPAMINE; MEDIA;
D O I
10.1149/1945-7111/ac992b
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This research explores the use of interdigitated electrode arrays (IDE) screen-printed on paper substrate for electrochemical measurements in steady state. Since the steady state is strongly related to IDE dimensions, the accuracy and reproducibility of the fabrication process were assessed for stencils of 120- and 200-mesh. Simulations were used to predict the limiting current and time response, and as a benchmark for comparison with the experimental results. For accurate an comparison, evaporation was prevented by using a homemade humidity box, which enabled measurements for periods as long as 30 min. Although cyclic voltammetry measurements in steady state were possible, this required at least 15 min per cycle when using the smallest electrodes (band width of 0.205 mm). Chronoamperometric measurements reaching steady state were also possible, requiring nearly 5 min for the largest electrodes (band width of 0.376 mm). Regarding the reproducibility of measurements, the relative standard deviations (RSD) of current and response time were near 12% and 26%, respectively. We attribute this mainly to the reproducibility of IDE fabrication (8% RSD). Experimental currents were approximately 30% to 34% of their simulated counterparts. Conversely, the simulated response times were about 30% to 50% of their experimental counterparts. We ascribe these discrepancies to the porosity of the paper (Whatman 2 CHR), estimated to be near 31% under wet conditions. This suggests that fibers inside the paper substrate block the passage of electrochemical species, thereby delaying their diffusion and decreasing the current. (C) 2022 The Author(s). Published on behalf of The Electrochemical Society by IOP Publishing Limited.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A steady-state and flow-through cell for screen-printed eight-electrode arrays
    Dock, E
    Christenson, A
    Sapelnikova, S
    Krejci, J
    Emnéus, J
    Ruzgas, T
    [J]. ANALYTICA CHIMICA ACTA, 2005, 531 (02) : 165 - 172
  • [2] Steady-state currents of planar interdigitated electrode arrays in shallow cells
    Yevenes, Cristian F. Guajardo
    Ngamchana, Sirimarn
    Surareungchai, Werasak
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2023, 950
  • [3] Development of disposable low density screen-printed electrode arrays for simultaneous electrochemical measurements of the hybridisation reaction
    Laschi, S.
    Palchetti, I.
    Marrazza, G.
    Mascini, M.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 593 (1-2): : 211 - 218
  • [4] Screen-printed electrode microarray for electrochemiluminescent measurements
    Corgier, BP
    Marquette, CA
    Blum, LJ
    [J]. ANALYTICA CHIMICA ACTA, 2005, 538 (1-2) : 1 - 7
  • [5] SCREEN-PRINTED ELECTRICALLY CONDUCTIVE FUNCTIONALITIES IN PAPER SUBSTRATES
    Zveglic, Masa
    Hauptman, Nina
    Macek, Marijan
    Gunde, Marta Klanjsek
    [J]. MATERIALI IN TEHNOLOGIJE, 2011, 45 (06): : 627 - 632
  • [6] Screen-printed diamond electrode: A disposable sensitive electrochemical electrode
    Kondo, Takeshi
    Sakamoto, Hironori
    Kato, Takayoshi
    Horitani, Masaru
    Shitanda, Isao
    Itagaki, Masayuki
    Yuasa, Makoto
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2011, 13 (12) : 1546 - 1549
  • [7] Modified screen-printed Electrode as Electrochemical Detector for Noscapine
    Aflatoonian, Mohammad Reza
    Jahani, Peyman Mohammadzadeh
    Aflatoonian, Behnaz
    Jafari, Maedeh
    Zhang, Kaiqiang
    Quyet Van Le
    Cha, Joo Hwan
    Shokouhimehr, Mohammadreza
    Peng, Wanxi
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (09): : 8612 - 8621
  • [8] Study on electrochemical biosensor based on screen-printed electrode
    Zou, Quan
    Cheng, Gong
    Zhang, Yu
    [J]. MODERN PHYSICS LETTERS B, 2018, 32 (34-36):
  • [9] Glycated Hemoglobin Electrochemical Immunosensor Based on Screen-Printed Electrode
    Zhao, Yuliang
    Zhang, Hongyu
    Li, Yang
    Wang, Xiaoai
    Zhao, Liang
    Xu, Jianghong
    Zhan, Zhikun
    Zhang, Guanglie
    Li, Wen Jung
    [J]. Biosensors, 2022, 12 (10):
  • [10] Screen-printed carbon electrode for the electrochemical detection of conjugated bilirubin
    Resmi, P. E.
    Raveendran, Jeethu
    Suneesh, P. V.
    Ramanchandran, T.
    Nair, Bipin G.
    Babu, T. G. Satheesh
    [J]. MATERIALS LETTERS, 2021, 304