New technologies for measuring intraocular pressure

被引:14
|
作者
Garcia-Feijoo, Julian [1 ,2 ]
Martinez-de-la-Casa, Jose Maria [1 ,2 ]
Morales-Fernandez, Laura [1 ,2 ]
Frances, Federico Saenz [1 ,2 ]
Santos-Bueso, Enrique [1 ,2 ]
Garcia-Saenz, Sofia [1 ,2 ]
Mendez-Hernandez, Carmen [1 ,2 ]
机构
[1] Univ Complutense Madrid, Inst Invest Sanitaria Hosp Clin San Carlos IdISSC, Hosp Clin San Carlos, Dept Oftalmol & ORL,Fac Med,Serv Oftalmol, Madrid, Spain
[2] Inst Salud Carlos III, Cooperat Res Network Age Related Ocular Pathol Vi, Madrid, Spain
来源
NEW TRENDS IN BASIC AND CLINICAL RESEARCH OF GLAUCOMA: A NEURODEGENERATIVE DISEASE OF THE VISUAL SYSTEM, PT B | 2015年 / 221卷
关键词
Intraocular pressure; Tonometer; Goldmann; Corneal thickness; Corneal hysteresis; Dynamic contour; Pascal; Corvis; Ocular response analyzer; ICare; Rebound; Sensimed; GOLDMANN APPLANATION TONOMETRY; OCULAR HYPERTENSION TREATMENT; DYNAMIC CONTOUR TONOMETRY; CORNEAL THICKNESS; REBOUND TONOMETER; ICARE; NONCONTACT; TGDC-01; ONSET;
D O I
10.1016/bs.pbr.2015.06.003
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The level of intraocular pressure (IOP) is the main known risk factor for the development and progression of glaucomatous optic neuropathy. Despite Goldmann applanation tonometry (GAT) being the gold standard for determining IOP since the last century, its limitations were obvious from the start and include substantial effects of several eye variables such as axial length, curvature, rigidity, and corneal thickness. These limitations have prompted the development of numerous formulas and nomograms designed to compensate for the ocular characteristics effect on GAT, but none of these methods has been entirely satisfactory. Similarly, as a result of efforts to mitigate some of the limitations of conventional tonometry, several new tonometers have appeared on the scene.
引用
收藏
页码:67 / 79
页数:13
相关论文
共 50 条
  • [41] Mathematical modeling of Maklakoff’s method for measuring the intraocular pressure
    S. M. Bauer
    G. A. Lyubimov
    P. E. Tovstik
    Fluid Dynamics, 2005, 40 : 20 - 33
  • [42] NEW METHOD FOR MEASURING PRESSURE
    UNGER, P
    TENGBERG, JE
    KLASSON, B
    LANCET, 1970, 1 (7653): : 924 - &
  • [43] A new foldable sensor-IOL for measuring intraocular pressure in glaucomatous human eyes - Results in vivo.
    Dinslage, S
    Walter, P
    Diestelhorst, M
    Krieglstein, GK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S830 - S830
  • [44] Measuring Real-Time Corneal Elasticity Standardized to Intraocular Pressure
    McCafferty, Sean Joseph
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [45] Comparison of a rebound and an applanation tonometer for measuring intraocular pressure in normal rabbits
    Pereira, Fabiana Quartiero
    Bercht, Bernardo Stefano
    Soares, Mirian Gomes
    Bittencourt da Mota, Mauricio Grillo
    Tadeu Pigatto, Joao Antonio
    VETERINARY OPHTHALMOLOGY, 2011, 14 (05) : 321 - 326
  • [46] Potential for measuring intraocular pressure using static OCT corneal images
    Niemczyk, Marcela
    Iskander, D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [47] Repeatability, reproducibility, and agreement of three tonometers for measuring intraocular pressure in rabbits
    Christian J. F. Bertens
    Ralph J. S. van Mechelen
    Tos T. J. M. Berendschot
    Marlies Gijs
    Jarno E. J. Wolters
    Theo G. M. F. Gorgels
    Rudy M. M. A. Nuijts
    Henny J. M. Beckers
    Scientific Reports, 11
  • [48] COMPARISON OF 3 TONOMETERS FOR MEASURING INTRAOCULAR-PRESSURE (IOP) IN RABBITS
    ABRAMS, L
    JAMPEL, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1857 - 1857
  • [49] Repeatability, reproducibility, and agreement of three tonometers for measuring intraocular pressure in rabbits
    Bertens, Christian J. F.
    van Mechelen, Ralph J. S.
    Berendschot, Tos T. J. M.
    Gijs, Marlies
    Wolters, Jarno E. J.
    Gorgels, Theo G. M. F.
    Nuijts, Rudy M. M. A.
    Beckers, Henny J. M.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [50] Assessment of IcareONE rebound tonometer for self-measuring intraocular pressure
    Parodi, Maurizio Battaglia
    Iacono, Pierluigi
    Campa, Claudio
    La Spina, Carlo
    Triolo, Giacinto
    Lattanzio, Rosangela
    Bandello, Francesco