Repeatability, reproducibility, and agreement of three tonometers for measuring intraocular pressure in rabbits

被引:0
|
作者
Christian J. F. Bertens
Ralph J. S. van Mechelen
Tos T. J. M. Berendschot
Marlies Gijs
Jarno E. J. Wolters
Theo G. M. F. Gorgels
Rudy M. M. A. Nuijts
Henny J. M. Beckers
机构
[1] Maastricht University Medical Center+ (MUMC+),Department of Ophthalmology, University Eye Clinic Maastricht, School for Mental Health and Neuroscience (MHeNs)
[2] Chemelot Institute for Science and Technology (InSciTe),undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to evaluate repeatability, reproducibility, and agreement of three commonly used tonometers in animal research (TonoLab, TonoVet, and TonoPEN AVIA) in a cohort of 24 rabbits. Additionally, the impact of sedation on IOP was investigated in 21 New Zealand White rabbits with the TonoVet tonometer. Repeatability was determined using the coefficient of variation (CoV) for two observers. For the TonoLab (6.55%) and TonoVet (6.38%) the CoV was lower than for the TonoPEN AVIA (10.88%). The reproducibility was highest for the TonoVet (0.2 ± 3.3 mmHg), followed by the TonoLab (0 ± 12.89 mmHg) and lowest for the TonoPEN AVIA (− 1.48 ± 10.3 mmHg). The TonoLab and TonoVet showed the highest agreement (r = 0.85, R2 = 0.73). After sedation, a significant IOP reduction (often > 25%) was observed. Our results show that among the three tonometers tested, the TonoVet tonometer is best for use in rabbits while the TonoLab should be avoided. The impact of sedation on IOP was substantial and should be taken into account during experimentation.
引用
收藏
相关论文
共 50 条
  • [1] Repeatability, reproducibility, and agreement of three tonometers for measuring intraocular pressure in rabbits
    Bertens, Christian J. F.
    van Mechelen, Ralph J. S.
    Berendschot, Tos T. J. M.
    Gijs, Marlies
    Wolters, Jarno E. J.
    Gorgels, Theo G. M. F.
    Nuijts, Rudy M. M. A.
    Beckers, Henny J. M.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [2] Repeatability and agreement of intraocular pressure measurement among three tonometers
    Sanchez Pavon, Irene
    Canadas, Pilar
    Martin, Raul
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2020, 103 (06) : 808 - 812
  • [3] Comparison of three tonometers for measuring intraocular pressure in rabbits
    Abrams, LS
    Vitale, S
    Jampel, HD
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (05) : 940 - 944
  • [4] Agreement of rebound tonometer in measuring intraocular pressure with three types of applanation tonometers
    Nakamura, Makoto
    Darhad, Urtogtah
    Tatsumi, Yasuko
    Fujioka, Miyuki
    Kusuhara, Azusa
    Maeda, Hidetaka
    Negi, Akira
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (02) : 332 - 334
  • [5] Repeatability, reproducibility and agreement of intraocular pressure measurement in rabbits by the TonoVet and Tono-Pen
    Ma, Di
    Chen, Chong-Bo
    Liang, Jiajian
    Lu, Zhihao
    Chen, Haoyu
    Zhang, Mingzhi
    SCIENTIFIC REPORTS, 2016, 6
  • [6] Repeatability, reproducibility and agreement of intraocular pressure measurement in rabbits by the TonoVet and Tono-Pen
    Di Ma
    Chong-Bo Chen
    Jiajian Liang
    Zhihao Lu
    Haoyu Chen
    Mingzhi Zhang
    Scientific Reports, 6
  • [7] COMPARISON OF 3 TONOMETERS FOR MEASURING INTRAOCULAR-PRESSURE (IOP) IN RABBITS
    ABRAMS, L
    JAMPEL, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1857 - 1857
  • [8] Estimation of intraocular pressure in rabbits with commonly used tonometers
    Acosta, Ana C.
    Espana, Edgar M.
    Nose, Izuru
    Orozco, Marcia
    Yamamoto, Hideo
    Venkatraman, Anna S.
    Fantes, Francisco
    Parel, Jean-Marie
    OPHTHALMIC SURGERY LASERS & IMAGING, 2007, 38 (01) : 43 - 49
  • [9] Repeatability, Reproducibility, and Agreement Between Three Different Scheimpflug Systems in Measuring Corneal and Anterior Segment Biometry
    Hernandez-Camarena, Julio C.
    Chirinos-Saldana, Patricia
    Navas, Alejandro
    Ramirez-Miranda, Arturo
    de la Mota, Angie
    Jimenez-Corona, Aida
    Graue-Hernandez, Enrique O.
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (09) : 616 - U44
  • [10] Intraocular pressure and photorefractive keratectomy - A comparison of three different tonometers
    Garzozi, HJ
    Chung, HS
    Lang, YR
    Kagemann, L
    Harris, A
    CORNEA, 2001, 20 (01) : 33 - 36