Validation of aortic valve pressure gradient quantification using semi-automated 4D flow CMR pipeline

被引:3
|
作者
Grafton-Clarke, Ciaran [1 ]
Njoku, Paul [1 ]
Aben, Jean-Paul [2 ]
Ledoux, Leon [2 ]
Zhong, Liang [3 ]
Westenberg, Jos [4 ]
Swift, Andrew [5 ]
Archer, Gareth [5 ]
Wild, James [5 ]
Hose, Rod [5 ]
Flather, Marcus [1 ]
Vassiliou, Vassilios S. [1 ]
Garg, Pankaj [1 ]
机构
[1] Univ East Anglia, Norwich Med Sch, Norwich S10 2RX, Norfolk, England
[2] Pie Med Imaging, Maastricht, Netherlands
[3] Natl Heart Ctr, Singapore, Singapore
[4] Leids Univ, Med Ctr, Leiden, Netherlands
[5] Univ Sheffield, Sheffield, S Yorkshire, England
基金
英国惠康基金;
关键词
Aortic stenosis; Cardiac MRI; Validation; VALVULAR HEART-DISEASE; EUROPEAN ASSOCIATION; STENOSIS; SOCIETY;
D O I
10.1186/s13104-022-06033-z
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective Doppler echocardiographic aortic valve peak velocity and peak pressure gradient assessment across the aortic valve (AV) is the mainstay for diagnosing aortic stenosis. Four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) is emerging as a valuable diagnostic tool for estimating the peak pressure drop across the aortic valve, but assessment remains cumbersome. We aimed to validate a novel semi-automated pipeline 4D flow CMR method of assessing peak aortic value pressure gradient (AVPG) using the commercially available software solution, CAAS MR Solutions, against invasive angiographic methods. Results We enrolled 11 patients with severe AS on echocardiography from the EurValve programme. All patients had pre-intervention doppler echocardiography, invasive cardiac catheterisation with peak pressure drop assessment across the AV and 4D flow CMR. The peak AVPG was 51.9 +/- 35.2 mmHg using the invasive pressure drop method and 52.2 +/- 29.2 mmHg for the 4D flow CMR method (semi-automated pipeline), with good correlation between the two methods (r = 0.70, p = 0.017). Assessment of AVPG by 4D flow CMR using the novel semi-automated pipeline method shows excellent agreement to invasive assessment when compared to doppler-based methods and advocate for its use as complementary to echocardiography.
引用
下载
收藏
页数:7
相关论文
共 50 条
  • [41] Validation of blood flow partitioning in 4D phase contrast CMR measurements using lagrangian coherent structures
    Töger J.
    Carlsson M.
    Söderlind G.
    Arheden H.
    Heiberg E.
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [42] 4D flow CMR vs. 2D cine PC-CMR for flow volume quantification in congenital heart disease
    Prsa, M.
    Tenisch, E.
    Piccini, D.
    Ning, J.
    Bouchardy, J.
    Blanche, C.
    Sekarski, N.
    Pavon, A.
    Vincenti, G.
    Rodrigues, D.
    Stuber, M.
    Schwitter, J.
    Rutz, T.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 : 493 - 493
  • [43] Relative Aortic Blood Pressure Using 4D Flow MRI: Associations with Age and Aortic Tapering
    Bouaou, Kevin
    Bargiotas, Ioannis
    Craiem, Damian
    Soulat, Gilles
    Dietenbeck, Thomas
    Houriez-Gombaud-Saintonge, Sophia
    De Cesare, Alain
    Gencer, Umit
    Giron, Alain
    Redheuil, Alban
    Lucor, Didier
    Mousseaux, Elie
    Kachenoura, Nadjia
    2017 COMPUTING IN CARDIOLOGY (CINC), 2017, 44
  • [44] Type of aortic valve replacement influences ascending aortic flow characteristics - a pilot study using 4D flow MRI
    Florian von Knobelsdorff-Brenkenhoff
    Ralf F Trauzeddel
    Alex J Barker
    Henriette Gruettner
    Michael Markl
    Jeanette Schulz-Menger
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [45] Reproducibility of Transluminal Attenuation Gradient Measurement Using Semi-automated Coronary Computed Tomography Quantification Software
    Matsumoto, Suguru
    Nakanishi, Rine
    Alani, Anas
    Fahmy, Michael A.
    Abraham, Jeby
    Li, Dong
    Dailing, Christpher
    Flores, Ferdinand
    Kitslaar, Pieter
    Broersen, Alexander
    Budoff, Matthew J.
    CIRCULATION, 2014, 130
  • [46] Qualitative grading of aortic regurgitation: a pilot study comparing CMR 4D flow and echocardiography
    Chelu, Raluca G.
    van den Bosch, Annemien E.
    van Kranenburg, Matthijs
    Hsiao, Albert
    van den Hoven, Allard T.
    Ouhlous, Mohamed
    Budde, Ricardo P. J.
    Beniest, Kirsten M.
    Swart, Laurens E.
    Coenen, Adriaan
    Lubbers, Marisa M.
    Wielopolski, Piotr A.
    Vasanawala, Shreyas S.
    Roos-Hesselink, Jolien W.
    Nieman, Koen
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (02): : 301 - 307
  • [47] Qualitative grading of aortic regurgitation: a pilot study comparing CMR 4D flow and echocardiography
    Raluca G. Chelu
    Annemien E. van den Bosch
    Matthijs van Kranenburg
    Albert Hsiao
    Allard T. van den Hoven
    Mohamed Ouhlous
    Ricardo P. J. Budde
    Kirsten M. Beniest
    Laurens E. Swart
    Adriaan Coenen
    Marisa M. Lubbers
    Piotr A. Wielopolski
    Shreyas S. Vasanawala
    Jolien W. Roos-Hesselink
    Koen Nieman
    The International Journal of Cardiovascular Imaging, 2016, 32 : 301 - 307
  • [48] Visualisation of aortic flow disturbance in Marfan syndrome by 4D phase-contrast CMR
    Alex Pitcher
    Tom E Cassar
    Joseph Suttie
    Jane M Francis
    Paul Leeson
    Edward Blair
    B Paul Wordsworth
    J Colin Forfar
    Saul G Myerson
    Michael Markl
    Stefan Neubauer
    Steffen E Petersen
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [49] 4D flow cardiovascular magnetic resonance for monitoring of aortic valve repair in bicuspid aortic valve disease
    Alexander Lenz
    Johannes Petersen
    Christoph Riedel
    Julius M. Weinrich
    Hendrik Kooijman
    Bjoern P. Schoennagel
    Gerhard Adam
    Yskert von Kodolitsch
    Hermann Reichenspurner
    Evaldas Girdauskas
    Peter Bannas
    Journal of Cardiovascular Magnetic Resonance, 22
  • [50] 4D flow cardiovascular magnetic resonance for monitoring of aortic valve repair in bicuspid aortic valve disease
    Lenz, Alexander
    Petersen, Johannes
    Riedel, Christoph
    Weinrich, Julius M.
    Kooijman, Hendrik
    Schoennagel, Bjoern P.
    Adam, Gerhard
    von Kodolitsch, Yskert
    Reichenspurner, Hermann
    Girdauskas, Evaldas
    Bannas, Peter
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)