Qualitative grading of aortic regurgitation: a pilot study comparing CMR 4D flow and echocardiography

被引:0
|
作者
Raluca G. Chelu
Annemien E. van den Bosch
Matthijs van Kranenburg
Albert Hsiao
Allard T. van den Hoven
Mohamed Ouhlous
Ricardo P. J. Budde
Kirsten M. Beniest
Laurens E. Swart
Adriaan Coenen
Marisa M. Lubbers
Piotr A. Wielopolski
Shreyas S. Vasanawala
Jolien W. Roos-Hesselink
Koen Nieman
机构
[1] Erasmus MC,Department of Radiology
[2] Erasmus MC,Department of Cardiology
[3] University of California,Department of Radiology
[4] San Diego,Department of Radiology
[5] Stanford University,undefined
关键词
Cardiac; Phase contrast; CMR 4D flow imaging; Eddy currents correction; Aortic regurgitation; Flow visualization;
D O I
暂无
中图分类号
学科分类号
摘要
Over the past 10 years there has been intense research in the development of volumetric visualization of intracardiac flow by cardiac magnetic resonance (CMR). This volumetric time resolved technique called CMR 4D flow imaging has several advantages over standard CMR. It offers anatomical, functional and flow information in a single free-breathing, ten-minute acquisition. However, the data obtained is large and its processing requires dedicated software. We evaluated a cloud-based application package that combines volumetric data correction and visualization of CMR 4D flow data, and assessed its accuracy for the detection and grading of aortic valve regurgitation using transthoracic echocardiography as reference. Between June 2014 and January 2015, patients planned for clinical CMR were consecutively approached to undergo the supplementary CMR 4D flow acquisition. Fifty four patients (median age 39 years, 32 males) were included. Detection and grading of the aortic valve regurgitation using CMR 4D flow imaging were evaluated against transthoracic echocardiography. The agreement between 4D flow CMR and transthoracic echocardiography for grading of aortic valve regurgitation was good (κ = 0.73). To identify relevant, more than mild aortic valve regurgitation, CMR 4D flow imaging had a sensitivity of 100 % and specificity of 98 %. Aortic regurgitation can be well visualized, in a similar manner as transthoracic echocardiography, when using CMR 4D flow imaging.
引用
下载
收藏
页码:301 / 307
页数:6
相关论文
共 50 条
  • [1] Qualitative grading of aortic regurgitation: a pilot study comparing CMR 4D flow and echocardiography
    Chelu, Raluca G.
    van den Bosch, Annemien E.
    van Kranenburg, Matthijs
    Hsiao, Albert
    van den Hoven, Allard T.
    Ouhlous, Mohamed
    Budde, Ricardo P. J.
    Beniest, Kirsten M.
    Swart, Laurens E.
    Coenen, Adriaan
    Lubbers, Marisa M.
    Wielopolski, Piotr A.
    Vasanawala, Shreyas S.
    Roos-Hesselink, Jolien W.
    Nieman, Koen
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (02): : 301 - 307
  • [2] Grading mitral regurgitation using 4D flow CMR: Comparison to transthoracic echocardiography
    Ribeyrolles, Sophie
    Monin, Jean-Luc
    Rohnean, Adela
    Diakov, Christelle
    Caussin, Christophe
    Monnot, Sebastien
    Berrebi, Alain
    Paul, Jean-Francois
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2022, 39 (06): : 783 - 793
  • [3] Grading mitral regurgitation using 4D flow CMR: comparison to transthoracic echocardiography
    Ribeyrolles, S.
    Monin, J. L.
    Rohnean, A.
    Diakov, C.
    Caussin, C.
    Monnot, S.
    Paul, J. F.
    EUROPEAN HEART JOURNAL, 2021, 42 : 174 - 174
  • [4] Clinical use of 4D flow MRI for quantification of aortic regurgitation
    Alvarez, Ana
    Martinez, Vicente
    Pizarro, Gonzalo
    Recio, Manuel
    Angel Cabrera, Jose
    OPEN HEART, 2020, 7 (01):
  • [5] 4D Flow CMR in Assessment of Valve-Related Ascending Aortic Disease
    Hope, Michael D.
    Hope, Thomas A.
    Crook, Stephen E. S.
    Ordovas, Karen G.
    Urbania, Thomas H.
    Alley, Marc T.
    Higgins, Charles B.
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (07) : 781 - 787
  • [6] Remote CMR 4D Flow Quantification of Pulmonary Flow
    Raluca G Saru
    Kevin Wanambiro
    Albert Hsiao
    Laurens E Swart
    Sara Boccalini
    Mika Vogel
    Ricardo Budde
    Shreyas Vasanawala
    Jolien Roos-Hesselink
    Koen Nieman
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [7] Partial fusion of two aortic valve leaflets is related to alterations in ascending aorta flow: 4D flow CMR study
    Guala, A.
    Galian, L.
    Teixido Tura, G.
    Dux-Santoy, L.
    Ruiz Munoz, A.
    Granato, C.
    Valente, F.
    La Mura, L.
    Gutierrez, L.
    Lopez Sainz, A.
    Johnson, K. M.
    Wieben, O.
    Sao Aviles, A.
    Evangelista, A.
    Rodriguez-Palomares, J. F.
    EUROPEAN HEART JOURNAL, 2019, 40 : 175 - 175
  • [8] Mechanical dyssynchrony alters left ventricular flow energetics in failing hearts with LBBB: a 4D flow CMR pilot study
    Jakub Zajac
    Jonatan Eriksson
    Urban Alehagen
    Tino Ebbers
    Ann F. Bolger
    Carl-Johan Carlhäll
    The International Journal of Cardiovascular Imaging, 2018, 34 : 587 - 596
  • [9] Mechanical dyssynchrony alters left ventricular flow energetics in failing hearts with LBBB: a 4D flow CMR pilot study
    Zajac, Jakub
    Eriksson, Jonatan
    Alehagen, Urban
    Ebbers, Tino
    Bolger, Ann F.
    Carlhall, Carl-Johan
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (04): : 587 - 596
  • [10] Towards a comprehensive description of relative aortic pressure: insights from 4D flow CMR
    Alex Pitcher
    Pablo Lamata
    Sebastian B Krittian
    David A Nordslettern
    Malenka M Bissell
    Jane M Francis
    Thomas E Cassar
    Alex J Barker
    Michael Markl
    Stefan Neubauer
    Nic Smith
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)