Blood Flow Mimicking Aneurysmal Wall Enhancement: A Diagnostic Pitfall of Vessel Wall MRI Using the Postcontrast 3D Turbo Spin-Echo MR Imaging Sequence

被引:37
|
作者
Kalsoum, E. [1 ]
Negrier, A. Chabernaud [1 ]
Tuilier, T. [1 ]
Benaissa, A. [1 ]
Blanc, R. [3 ]
Gallas, S. [1 ]
Lefaucheur, J. -P. [2 ]
Gaston, A. [1 ]
Lopes, R. [4 ]
Brugieres, P. [1 ]
Hodel, J. [1 ]
机构
[1] CHU Henri Mondor, Dept Neuroradiol, Creteil, France
[2] CHU Henri Mondor, Dept Neurophysiol, Creteil, France
[3] Rothschild Fdn Hosp, Dept Intervent Neuroradiol, Paris, France
[4] Univ Lille, Degenerat & Vasc Cognit Disorders U1171, INSERM, Neuroradiol Dept,CHU Lille, Lille, France
关键词
INTRACRANIAL ANEURYSMS;
D O I
10.3174/ajnr.A5616
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Our aim was to compare the detectability of aneurysmal wall enhancement in unruptured intracranial aneurysms between conventional and motion-sensitized driven equilibrium-prepared postcontrast 3D T1-weighted TSE sequences (sampling perfection with applicationoptimized contrasts by using different flip angle evolution, SPACE). Twenty-two patients with 30 unruptured intracranial aneurysms were scanned at 3T. Aneurysmal wall enhancement was more significantly detected using conventional compared with motion-sensitized driven equilibrium-prepared SPACE sequences (10/30 versus 2/30, P < .0001). Contrast-to-noise ratio measurements did not differ between conventional and motion-sensitized driven equilibrium-prepared sequences (P = .51). Flowing blood can mimic aneurysmal wall enhancement using conventional SPACE sequences with potential implications for patient care.
引用
收藏
页码:1065 / 1067
页数:3
相关论文
共 50 条
  • [21] 3D volume-selective turbo spin echo for carotid artery wall imaging with navigator detection of swallowing
    Crowe, LA
    Keegan, J
    Gatehouse, PD
    Mohiaddin, RH
    Varghese, A
    Symmonds, K
    Cannell, TM
    Yang, GZ
    Firmin, DN
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (04) : 583 - 588
  • [22] MRI of the regions of inner ear and cerebellopontine angle using a 3D T-2-weighted turbo spin-echo sequence: Comparison with conventional 2D T-2-weighted turbo spin-echo sequences and T-1-weighted spin-echo sequences.
    Czerny, C
    Trattnig, S
    Baumgartner, WD
    Gstottner, W
    Imhof, H
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 167 (04): : 377 - 383
  • [23] Whole-Brain Intracranial Vessel Wall Imaging at 3 Tesla Using Cerebrospinal Fluid-Attenuated T1-Weighted 3D Turbo Spin Echo
    Fan, Zhaoyang
    Yang, Qi
    Deng, Zixin
    Li, Yuxia
    Bi, Xiaoming
    Song, Shlee
    Li, Debiao
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (03) : 1142 - 1150
  • [24] Geometrically undistorted MRI in the presence of field inhomogeneities using compressed sensing accelerated broadband 3D phase encoded turbo spin-echo imaging
    van Gorp, Jetse S.
    Bakker, Chris J. G.
    Bouwman, Job G.
    Smink, Jouke
    Zijlstra, Frank
    Seevinck, Peter R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (02): : 615 - 631
  • [25] MR-IMAGING OF THE NORMAL MENINGES - COMPARISON OF CONTRAST-ENHANCEMENT PATTERNS ON 3D GRADIENT-ECHO AND SPIN-ECHO IMAGES
    FARN, JW
    MIROWITZ, SA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 131 - 135
  • [26] MRI of the lumbar spine: comparison of 3D isotropic turbo spin-echo SPACE sequence versus conventional 2D sequences at 3.0 T
    Lee, Sungwon
    Jee, Won-Hee
    Jung, Joon-Yong
    Lee, So-Yeon
    Ryu, Kyeung-Sik
    Ha, Kee-Yong
    ACTA RADIOLOGICA, 2015, 56 (02) : 174 - 181
  • [27] SLAP tears: diagnosis using 3-T shoulder MR arthrography with the 3D isotropic turbo spin-echo space sequence versus conventional 2D sequences
    Jung, Joon-Yong
    Jee, Won-Hee
    Park, Michael Yong
    Lee, So-Yeon
    Kim, Yang-Soo
    EUROPEAN RADIOLOGY, 2013, 23 (02) : 487 - 495
  • [28] SLAP tears: diagnosis using 3-T shoulder MR arthrography with the 3D isotropic turbo spin-echo space sequence versus conventional 2D sequences
    Joon-Yong Jung
    Won-Hee Jee
    Michael Yong Park
    So-Yeon Lee
    Yang-Soo Kim
    European Radiology, 2013, 23 : 487 - 495
  • [29] Comprehensive Assessment of Ankle Syndesmosis Injury Using 3D Isotropic Turbo Spin-Echo Sequences: Diagnostic Performance Compared With That of Conventional and Oblique 3-T MRI
    Kim, Minchul
    Choi, Yun Sun
    Jeong, Min Sun
    Park, Mira
    Chun, Tong Jin
    Kim, Jin Su
    Young, Ki Won
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (04) : 827 - 833
  • [30] Cervical carotid plaque evaluation using 3D T1-weighted black-blood magnetic resonance imaging: Comparison of turbo field-echo and turbo spin-echo sequences
    Inoue, Katsuhiro
    Maeda, Masayuki
    Umino, Maki
    Takase, Shinichi
    Yamahata, Tsunehiro
    Sakuma, Hajime
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (05) : 1035 - 1039