Blood Flow Mimicking Aneurysmal Wall Enhancement: A Diagnostic Pitfall of Vessel Wall MRI Using the Postcontrast 3D Turbo Spin-Echo MR Imaging Sequence

被引:37
|
作者
Kalsoum, E. [1 ]
Negrier, A. Chabernaud [1 ]
Tuilier, T. [1 ]
Benaissa, A. [1 ]
Blanc, R. [3 ]
Gallas, S. [1 ]
Lefaucheur, J. -P. [2 ]
Gaston, A. [1 ]
Lopes, R. [4 ]
Brugieres, P. [1 ]
Hodel, J. [1 ]
机构
[1] CHU Henri Mondor, Dept Neuroradiol, Creteil, France
[2] CHU Henri Mondor, Dept Neurophysiol, Creteil, France
[3] Rothschild Fdn Hosp, Dept Intervent Neuroradiol, Paris, France
[4] Univ Lille, Degenerat & Vasc Cognit Disorders U1171, INSERM, Neuroradiol Dept,CHU Lille, Lille, France
关键词
INTRACRANIAL ANEURYSMS;
D O I
10.3174/ajnr.A5616
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Our aim was to compare the detectability of aneurysmal wall enhancement in unruptured intracranial aneurysms between conventional and motion-sensitized driven equilibrium-prepared postcontrast 3D T1-weighted TSE sequences (sampling perfection with applicationoptimized contrasts by using different flip angle evolution, SPACE). Twenty-two patients with 30 unruptured intracranial aneurysms were scanned at 3T. Aneurysmal wall enhancement was more significantly detected using conventional compared with motion-sensitized driven equilibrium-prepared SPACE sequences (10/30 versus 2/30, P < .0001). Contrast-to-noise ratio measurements did not differ between conventional and motion-sensitized driven equilibrium-prepared sequences (P = .51). Flowing blood can mimic aneurysmal wall enhancement using conventional SPACE sequences with potential implications for patient care.
引用
收藏
页码:1065 / 1067
页数:3
相关论文
共 50 条
  • [31] Improved Blood Suppression in Three-Dimensional (3D) Fast Spin-Echo (FSE) Vessel Wall Imaging Using a Combination of Double Inversion-Recovery (DIR) and Diffusion Sensitizing Gradient (DSG) Preparations
    Makhijani, Mahender K.
    Hu, Houchun H.
    Pohost, Gerry M.
    Nayak, Krishna S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (02) : 398 - 405
  • [32] Vessel-wall imaging and quantification of flow-mediated dilation using water-selective 3D SSFP-echo
    Langham, Michael C.
    Li, Cheng
    Englund, Erin K.
    Chirico, Erica N.
    Mohler, Emile R., III
    Floyd, Thomas F.
    Wehrli, Felix W.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15
  • [33] Vessel-wall imaging and quantification of flow-mediated dilation using water-selective 3D SSFP-echo
    Michael C Langham
    Cheng Li
    Erin K Englund
    Erica N Chirico
    Emile R Mohler
    Thomas F Floyd
    Felix W Wehrli
    Journal of Cardiovascular Magnetic Resonance, 15
  • [34] Quantitative 2D and 3D Phase Contrast MRI: Optimized Analysis of Blood Flow and Vessel Wall Parameters
    Stalder, A. F.
    Russe, M. F.
    Frydrychowicz, A.
    Bock, J.
    Hennig, J.
    Markl, M.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (05) : 1218 - 1231
  • [35] 3D T2-weighted turbo spin-echo MR sequence for identifying cerebrospinal fluid leak after endoscopic endonasal pituitary surgery
    Sang-Bong Chung
    Kyung-Su Kwag
    Sung Tae Kim
    Kwan Park
    Jong Hyun Kim
    Doo-Sik Kong
    Acta Neurochirurgica, 2012, 154 : 1499 - 1503
  • [36] Large coverage black-bright blood interleaved imaging sequence (LaBBI) for 3D dynamic contrast-enhanced MRI of vessel wall
    Qi, Haikun
    Huang, Feng
    Zhou, Zechen
    Koken, Peter
    Balu, Niranjan
    Zhang, Bida
    Yuan, Chun
    Chen, Huijun
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1334 - 1344
  • [37] 3D T2-weighted turbo spin-echo MR sequence for identifying cerebrospinal fluid leak after endoscopic endonasal pituitary surgery
    Chung, Sang-Bong
    Kwag, Kyung-Su
    Kim, Sung Tae
    Park, Kwan
    Kim, Jong Hyun
    Kong, Doo-Sik
    ACTA NEUROCHIRURGICA, 2012, 154 (08) : 1499 - 1503
  • [38] Knee Joint: Comprehensive Assessment with 3D Isotropic Resolution Fast Spin-Echo MR Imaging-Diagnostic Performance Compared with That of Conventional MR Imaging at 3.0 T
    Kijowski, Richard
    Davis, Kirkland W.
    Woods, Michael A.
    Lindstrom, Mary J.
    De Smet, Arthur A.
    Gold, Garry E.
    Busse, Reed F.
    RADIOLOGY, 2009, 252 (02) : 486 - 495
  • [39] High-resolution T2-weighted MR imaging of the inner ear using a long echo-train-length 3D east spin-echo sequence
    Naganawa, S
    Yamakawa, K
    Fukatsu, H
    Ishigaki, T
    Nakashima, T
    Sugimoto, H
    Aoki, I
    Miyazaki, M
    Takai, H
    EUROPEAN RADIOLOGY, 1996, 6 (03) : 369 - 374
  • [40] Supraspinatus tendon tears at 3.0 T shoulder MR arthrography: diagnosis with 3D isotropic turbo spin-echo SPACE sequence versus 2D conventional sequences
    Joon-Yong Jung
    Won-Hee Jee
    Michael Y. Park
    So-Yeon Lee
    Yang-Soo Kim
    Skeletal Radiology, 2012, 41 : 1401 - 1410