Geometrically undistorted MRI in the presence of field inhomogeneities using compressed sensing accelerated broadband 3D phase encoded turbo spin-echo imaging

被引:10
|
作者
van Gorp, Jetse S. [1 ]
Bakker, Chris J. G. [1 ,2 ]
Bouwman, Job G. [1 ]
Smink, Jouke [3 ]
Zijlstra, Frank [1 ]
Seevinck, Peter R. [1 ]
机构
[1] Univ Med Ctr Utrecht, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Radiol, NL-3584 CX Utrecht, Netherlands
[3] Philips Healthcare, Best, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 02期
关键词
geometrically accurate MRI; 3D phase encoded turbo spin-echo imaging; susceptibility; field inhomogeneities; compressed sensing; METAL; RADIOTHERAPY; DISTORTION; IMAGES; SUSCEPTIBILITY; SENSITIVITY; RESOLUTION; TOOL;
D O I
10.1088/0031-9155/60/2/615
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, we explore the potential of compressed sensing (CS) accelerated broadband 3D phase-encoded turbo spin-echo (3D-PE-TSE) for the purpose of geometrically undistorted imaging in the presence of field inhomogeneities. To achieve this goal 3D-PE-SE and 3D-PE-TSE sequences with broadband rf pulses and dedicated undersampling patterns were implemented on a clinical scanner. Additionally, a 3D multi-spectral spin-echo (ms3D-SE) sequence was implemented for reference purposes. First, we demonstrated the influence of susceptibility induced off-resonance effects on the spatial encoding of broadband 3D-SE, ms3D-SE, 3D-PE-SE and 3D-PE-TSE using a grid phantom containing a titanium implant (Delta chi= 182 ppm) with x-ray CT as a gold standard. These experiments showed that the spatial encoding of 3D-PE-(T) SE was unaffected by susceptibility induced off-resonance effects, which caused geometrical distortions and/or signal hyper-intensities in broadband 3D-SE and, to a lesser extent, in ms3D-SE frequency encoded methods. Additionally, an SNR analysis was performed and the temporally resolved signal of 3D-PE-(T) SE sequences was exploited to retrospectively decrease the acquisition bandwidth and obtain field offset maps. The feasibility of CS acceleration was studied retrospectively and prospectively for the 3D-PE-SE sequence using an existing CS algorithm adapted for the reconstruction of 3D data with undersampling in all three phase encoded dimensions. CS was combined with turbo-acceleration by variable density undersampling and spherical stepwise T-2 weighting by randomly sorting consecutive echoes in predefined spherical k-space layers. The CS-TSE combination resulted in an overall acceleration factor of 60, decreasing the original 3D-PE-SE scan time from 7 h to 7 min. Finally, CS accelerated 3D-PE-TSE in vivo images of a titanium screw were obtained within 10 min using a micro-coil demonstrating the feasibility of geometrically undistorted MRI near severe field inhomogeneities.
引用
收藏
页码:615 / 631
页数:17
相关论文
共 50 条
  • [1] Comparison of parallel MRI reconstruction methods for accelerated 3D fast spin-echo imaging
    Xiao, Zhikui
    Hoge, W. Scott
    Mulkern, R. V.
    Zhao, Lei
    Hu, Guangshu
    Kyriakos, Walid E.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) : 650 - 660
  • [2] Assessment of knee cartilage using accelerated 3 T MRI: Evaluation of an isotropic 3D fast spin-echo sequence (CUBE) with compressed sensing technique
    Willaume, Thibault
    Ehlinger, Matthieu
    Favreau, Henri
    Weingertner, Noelle
    Zorn, Pierre-Emmanuel
    Dillenseger, Jean-Philippe
    Koch, Guillaume
    Velten, Michel
    Bierry, Guillaume
    MAGNETIC RESONANCE IMAGING, 2025, 117
  • [3] Accelerated 3D carotid MRI using compressed sensing and parallel imaging
    Ricardo Otazo
    Li Feng
    Ruth Lim
    Qi Duan
    Graham Wiggins
    Daniel K Sodickson
    Daniel Kim
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [4] Accelerated 3D Lung MRI Using Compressed Sensing
    Sarma, M.
    Hu, P.
    Ennis, D.
    Thomas, M.
    Sheng, K.
    MEDICAL PHYSICS, 2012, 39 (06) : 3927 - 3927
  • [5] Multispectral 3D phase-encoded turbo spin-echo for imaging near metal: Limitations and possibilities demonstrated by simulations and phantom experiments
    van Gorp, Jetse S.
    Nizak, Razmara
    Bouwman, Job G.
    Saris, Daniel B. F.
    Seevinck, Peter R.
    MAGNETIC RESONANCE IMAGING, 2017, 39 : 31 - 43
  • [6] MRI of the lung: Value of different turbo spin-echo, single-shot turbo spin-echo, and 3D gradient-echo pulse sequences for the detection of pulmonary metastases
    Bruegel, Melanie
    Gaa, Jochen
    Woertler, Klaus
    Ganter, Carl
    Waldt, Simone
    Hillerer, Claudia
    Rummeny, Ernst J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (01) : 73 - 81
  • [7] ACCELERATED 3D MRI OF VOCAL TRACT SHAPING USING COMPRESSED SENSING AND PARALLEL IMAGING
    Kim, Yoon-Chul
    Narayanan, Shrikanth S.
    Nayak, Krishna S.
    2009 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOLS 1- 8, PROCEEDINGS, 2009, : 389 - 392
  • [8] Multi-shot turbo spin-echo for 3D vascular space occupancy imaging
    Cretti, Fabiola R.
    Summers, Paul E.
    Porro, Carlo A.
    MAGNETIC RESONANCE IMAGING, 2013, 31 (06) : 875 - 881
  • [9] Accelerating anatomical 2D turbo spin echo imaging of the ankle using compressed sensing
    Gersing, Alexandra S.
    Bodden, Jannis
    Neumann, Jan
    Diefenbach, Maximillian N.
    Kronthaler, Sophia
    Pfeiffer, Daniela
    Knebel, Carolin
    Baum, Thomas
    Schwaiger, Benedikt J.
    Hock, Andreas
    Rummeny, Ernst J.
    Woertler, Klaus
    Karampinos, Dimitrios C.
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 118 : 277 - 284
  • [10] Meniscal Tear Configurations: Categorization With 3D Isotropic Turbo Spin-Echo MRI Compared With Conventional MRI at 3 T
    Jung, Joon-Yong
    Jee, Won-Hee
    Park, Michael Y.
    Lee, So-Yeon
    Kim, Jung-Man
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (02) : W173 - W180