Geometrically undistorted MRI in the presence of field inhomogeneities using compressed sensing accelerated broadband 3D phase encoded turbo spin-echo imaging

被引:10
|
作者
van Gorp, Jetse S. [1 ]
Bakker, Chris J. G. [1 ,2 ]
Bouwman, Job G. [1 ]
Smink, Jouke [3 ]
Zijlstra, Frank [1 ]
Seevinck, Peter R. [1 ]
机构
[1] Univ Med Ctr Utrecht, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Radiol, NL-3584 CX Utrecht, Netherlands
[3] Philips Healthcare, Best, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 02期
关键词
geometrically accurate MRI; 3D phase encoded turbo spin-echo imaging; susceptibility; field inhomogeneities; compressed sensing; METAL; RADIOTHERAPY; DISTORTION; IMAGES; SUSCEPTIBILITY; SENSITIVITY; RESOLUTION; TOOL;
D O I
10.1088/0031-9155/60/2/615
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, we explore the potential of compressed sensing (CS) accelerated broadband 3D phase-encoded turbo spin-echo (3D-PE-TSE) for the purpose of geometrically undistorted imaging in the presence of field inhomogeneities. To achieve this goal 3D-PE-SE and 3D-PE-TSE sequences with broadband rf pulses and dedicated undersampling patterns were implemented on a clinical scanner. Additionally, a 3D multi-spectral spin-echo (ms3D-SE) sequence was implemented for reference purposes. First, we demonstrated the influence of susceptibility induced off-resonance effects on the spatial encoding of broadband 3D-SE, ms3D-SE, 3D-PE-SE and 3D-PE-TSE using a grid phantom containing a titanium implant (Delta chi= 182 ppm) with x-ray CT as a gold standard. These experiments showed that the spatial encoding of 3D-PE-(T) SE was unaffected by susceptibility induced off-resonance effects, which caused geometrical distortions and/or signal hyper-intensities in broadband 3D-SE and, to a lesser extent, in ms3D-SE frequency encoded methods. Additionally, an SNR analysis was performed and the temporally resolved signal of 3D-PE-(T) SE sequences was exploited to retrospectively decrease the acquisition bandwidth and obtain field offset maps. The feasibility of CS acceleration was studied retrospectively and prospectively for the 3D-PE-SE sequence using an existing CS algorithm adapted for the reconstruction of 3D data with undersampling in all three phase encoded dimensions. CS was combined with turbo-acceleration by variable density undersampling and spherical stepwise T-2 weighting by randomly sorting consecutive echoes in predefined spherical k-space layers. The CS-TSE combination resulted in an overall acceleration factor of 60, decreasing the original 3D-PE-SE scan time from 7 h to 7 min. Finally, CS accelerated 3D-PE-TSE in vivo images of a titanium screw were obtained within 10 min using a micro-coil demonstrating the feasibility of geometrically undistorted MRI near severe field inhomogeneities.
引用
收藏
页码:615 / 631
页数:17
相关论文
共 50 条
  • [41] MRI of intracranial vertebral artery dissection: evaluation of intramural haematoma using a black blood, variable-flip-angle 3D turbo spin-echo sequence
    Takano, Koichi
    Yamashita, Shinnichi
    Takemoto, Koichiro
    Inoue, Tooru
    Kuwabara, Yasuo
    Yoshimitsu, Kengo
    NEURORADIOLOGY, 2013, 55 (07) : 845 - 851
  • [42] MRI of intracranial vertebral artery dissection: evaluation of intramural haematoma using a black blood, variable-flip-angle 3D turbo spin-echo sequence
    Koichi Takano
    Shinnichi Yamashita
    Koichiro Takemoto
    Tooru Inoue
    Yasuo Kuwabara
    Kengo Yoshimitsu
    Neuroradiology, 2013, 55 : 845 - 851
  • [43] Technical note: Unexpected external markers artifact in 3D k-space based parallel imaging turbo spin-echo magnetic resonance imaging
    Crop, Frederik
    Mouttet-Audouard, Raphaelle
    Mirabel, Xavier
    Ceugnart, Luc
    Lacornerie, Thomas
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 90 : 150 - 157
  • [44] Optimized T1-weighted contrast for single-slab 3D turbo spin-echo imaging with long echo trains:: Application to whole-brain imaging
    Park, Jaeseok
    Mugler, John P., III
    Horger, Wilhelm
    Kiefer, Berthold
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (05) : 982 - 992
  • [45] Carotid Arterial Wall MRI at 3T Using 3D Variable-Flip-Angle Turbo Spin-Echo (TSE) with Flow-Sensitive Dephasing (FSD)
    Fan, Zhaoyang
    Zhang, Zhuoli
    Chung, Yiu-Cho
    Weale, Peter
    Zuehlsdorff, Sven
    Carr, James
    Li, Debiao
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (03) : 645 - 654
  • [46] Accelerated 3D T2-weighted images using compressed sensing for pediatric brain imaging
    Kim, Hyun Gi
    Oh, Se Won
    Han, Dongyeob
    Kim, Jee Young
    Lim, Gye Yeon
    NEURORADIOLOGY, 2022, 64 (12) : 2399 - 2407
  • [47] Accelerated 3D T2-weighted images using compressed sensing for pediatric brain imaging
    Hyun Gi Kim
    Se Won Oh
    Dongyeob Han
    Jee Young Kim
    Gye Yeon Lim
    Neuroradiology, 2022, 64 : 2399 - 2407
  • [48] Accelerated 3D echo-planar imaging with compressed sensing for time-resolved hyperpolarized 13C studies
    Geraghty, Benjamin J.
    Lau, Justin Y. C.
    Chen, Albert P.
    Cunningham, Charles H.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (02) : 538 - 546
  • [49] Highly accelerated 3D myocardial late fadolinium enhancement MRI using ESPIRiT compressed sensing: initial feasibility
    Peng Lai
    Piero Ghedin
    Gianluca Pontone
    Anja Brau
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [50] Locally advanced rectal cancer: 3D diffusion-prepared stimulated-echo turbo spin-echo versus 2D diffusion-weighted echo-planar imaging
    Zhang, Qinwei
    van Houdt, Petra J.
    Lambregts, Doenja M. J.
    van Triest, Baukelien
    Kop, Marnix P. M.
    Coolen, Bram F.
    Strijkers, Gustav J.
    van der Heide, Uulke A.
    Nederveen, Aart J.
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2020, 4 (01)