Carotid Arterial Wall MRI at 3T Using 3D Variable-Flip-Angle Turbo Spin-Echo (TSE) with Flow-Sensitive Dephasing (FSD)

被引:127
|
作者
Fan, Zhaoyang [1 ,2 ]
Zhang, Zhuoli [1 ]
Chung, Yiu-Cho [3 ]
Weale, Peter [3 ]
Zuehlsdorff, Sven [3 ]
Carr, James [1 ]
Li, Debiao [1 ,2 ]
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Evanston, IL 60208 USA
[3] Siemens Med Solut USA Inc, Chicago, IL USA
关键词
carotid artery; magnetic resonance imaging; atherosclerosis; 3D SPACE; black-blood; RAPID EXTENDED COVERAGE; BLACK-BLOOD MRI; ATHEROSCLEROTIC PLAQUE; MAGNETIC-RESONANCE; 1.5; T; ARTIFACTS; ANGIOGRAPHY; SEQUENCES; CONTRAST; LESIONS;
D O I
10.1002/jmri.22058
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the effectiveness of flow-sensitive dephasing (FSD) magnetization preparation in improving blood signal suppression of three-dimensional (3D) turbo spin-echo (TSE) sequence (SPACE) for isotropic high-spatial-resolution carotid arterial wall imaging at 3T. Materials and Methods: The FSD-prepared SPACE sequence (FSD-SPACE) was implemented by adding two identical FSD gradient pulses right before and after the first refocusing 180 degrees-pulse of the SPACE sequence in all three orthogonal directions. Nine healthy volunteers were imaged at 3T with SPACE, FSD-SPACE, and multislice T2-weighted 2D TSE coupled with saturation band (SB-TSE). Apparent carotid wall-lumen contrast-to-noise ratio (aCNR(w-1)) and apparent lumen area (aLA) at the locations with residual-blood (rb) signal shown on SPACE images were compared between SPACE and FSD-SPACE. Carotid aCNR(w-1) and lumen (LA) and wall area (WA) measured from FSD-SPACE were compared to those measured from SB-TSE. Results: Plaque-mimicking flow artifacts identified in seven carotids on SPACE images were eliminated on FSD-SPACE images. The FSD preparation resulted in slightly reduced aCNR(w-1) (P = 0.025), but significantly improved aCNR between the wall and rb regions (P < 0.001) and larger aLA (P < 0.001). Compared to SB-TSE, FSD-SPACE offered comparable aCNR(w-1) with much higher spatial resolution, shorter imaging time, and larger artery coverage. The LA and WA measurements from the two techniques were in good agreement based on intraclasss correlation coefficient (0.988 and 0.949, respectively; P < 0.001) and Bland-Altman analyses. Conclusion: FSD-SPACE is a time-efficient 3D imaging technique for carotid arterial wall with superior spatial resolution and blood signal suppression.
引用
收藏
页码:645 / 654
页数:10
相关论文
共 50 条
  • [1] Variable-flip-angle 3D spiral-in-out turbo spin-echo imaging using concomitant gradient compensation and echo reordering at 0.55T
    Wang, Zhixing
    Ramasawmy, Rajiv
    Javed, Ahsan
    Mugler, John P., III
    Meyer, Craig H.
    Campbell-Washburn, Adrienne E.
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (04) : 1741 - 1750
  • [2] MRI of intracranial vertebral artery dissection: evaluation of intramural haematoma using a black blood, variable-flip-angle 3D turbo spin-echo sequence
    Takano, Koichi
    Yamashita, Shinnichi
    Takemoto, Koichiro
    Inoue, Tooru
    Kuwabara, Yasuo
    Yoshimitsu, Kengo
    NEURORADIOLOGY, 2013, 55 (07) : 845 - 851
  • [3] MRI of intracranial vertebral artery dissection: evaluation of intramural haematoma using a black blood, variable-flip-angle 3D turbo spin-echo sequence
    Koichi Takano
    Shinnichi Yamashita
    Koichiro Takemoto
    Tooru Inoue
    Yasuo Kuwabara
    Kengo Yoshimitsu
    Neuroradiology, 2013, 55 : 845 - 851
  • [4] Characterization of carotid atherosclerosis with black-blood carotid plaque imaging using variable flip-angle 3D turbo spin-echo: Comparison with 2D turbo spin-echo sequences
    Takano, Koichi
    Yamashita, Shinnichi
    Takemoto, Koichiro
    Inoue, Tooru
    Sakata, Noriyuki
    Kuwabara, Yasuo
    Yoshimitsu, Kengo
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (03) : E304 - E309
  • [5] Prospective swallowing motion self-gating: a feasibility study in carotid artery wall MRI using 3D variable-flip-angle TSE
    Zhaoyang Fan
    Sven Zuehlsdorff
    Xin Liu
    Debiao Li
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [6] Prospective self-gating for swallowing motion: A feasibility study in carotid artery wall MRI using three-dimensional variable-flip-angle turbo spin-echo
    Fan, Zhaoyang
    Zuehlsdorff, Sven
    Liu, Xin
    Li, Debiao
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) : 490 - 498
  • [7] 3D Blood Flow Characteristics in the Carotid Artery Bifurcation Assessed by Flow-Sensitive 4D MRI at 3T
    Harloff, A.
    Albrecht, F.
    Spreer, J.
    Stalder, A. F.
    Bock, J.
    Frydrychowicz, A.
    Schoellhorn, J.
    Hetzel, A.
    Schumacher, M.
    Hennig, J.
    Markl, M.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (01) : 65 - 74
  • [8] Meniscal Tear Configurations: Categorization With 3D Isotropic Turbo Spin-Echo MRI Compared With Conventional MRI at 3 T
    Jung, Joon-Yong
    Jee, Won-Hee
    Park, Michael Y.
    Lee, So-Yeon
    Kim, Jung-Man
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (02) : W173 - W180
  • [9] Comparison of Gated and Ungated Black-Blood Fast Spin-echo MRI of Carotid Vessel Wall at 3T
    Zhu, Chengcheng
    Graves, Martin J.
    Sadat, Umar
    Young, Victoria E.
    Gillard, Jonathan H.
    Patterson, Andrew J.
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2016, 15 (03) : 266 - 272
  • [10] Identification and quantitative evaluation of symptomatic cerebral venous thrombosis using 3D variable flip angle turbo spin echo
    Xiong, Jingtong
    Liu, Ying
    Zhang, Chen
    Chen, Honghai
    Bian, Jie
    Qu, Xiaofeng
    MAGNETIC RESONANCE IMAGING, 2023, 103 : 131 - 138