Subcutaneous implantable cardioverter defibrillators in patients with left ventricular assist devices: case report and comprehensive review

被引:10
|
作者
Lopez-Gil, Maria [1 ,2 ]
Fontenla, Adolfo [1 ,2 ]
Delgado, Juan F. [2 ,3 ,4 ,5 ]
Rodriguez-Munoz, Daniel [1 ]
机构
[1] 12 Octubre Univ Hosp, Cardiol Dept, Cardiac Electrophysiol & Arrhythmia Unit, Avda Cordoba S-N, Madrid 28041, Spain
[2] 12 Octubre Univ Hosp, Avda Cordoba S-N, Madrid 28041, Spain
[3] 12 Octubre Univ Hosp, Cardiol Dept, Heart Failure & Heart Transplantat Program, Avda Cordoba S-N, Madrid 28041, Spain
[4] Univ Complutense, Fac Med, Avda Seneca 2, Madrid 28040, Spain
[5] CIBER CV, C Melchor Fernandez Almagro 3, Madrid 28029, Spain
关键词
Left ventricular assist devices; Subcutaneous implantable cardioverter defibrillator; Electromagnetic interferences; Undersensing; Case report; ELECTRONIC DEVICES;
D O I
10.1093/ehjcr/ytz057
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Left ventricular assist devices (LVAD) are increasingly used in patients with advanced heart failure, many of whom have been or will be implanted with an implantable cardioverter defibrillator (ICD). Interaction between both devices is a matter of concern. Subcutaneous ICD (S-ICD) obtains its signals through subcutaneous vectors, which poses special challenges with regards to adequate performance following LVAD implantation. Case summary We describe the case of a 24-year-old man implanted with an S-ICD because of idiopathic dilated cardiomyopathy, severe biventricular dysfunction, and self-limiting sustained ventricular tachycardias. After the implantation of a HeartMate 3TM (Left Ventricular Assist System, Abbott) several months later, the S-ICD became useless because of inappropriate sensing due to electromagnetic interference and attenuation of QRS voltage. Discussion We reviewed the reported cases in PubMed about the concomitant use of S-ICD and LVAD. Seven case reports about the performance of S-ICD in patients with an LVAD were identified, with discordant results. From these articles, we analyse the potential causes for these differing results. Pump location and operating rates in LVAD, as well as changes in the subcutaneous-electrocardiogram detected by the S-ICD after LVAD implantation are related to sensing disturbances when used in the same patient.
引用
下载
收藏
页数:6
相关论文
共 50 条
  • [41] Eligibility for subcutaneous implantable cardioverter-defibrillator in patients with left ventricular assist device
    Christos Zormpas
    Jörg Eiringhaus
    Henrike A. K. Hillmann
    Stephan Hohmann
    Johanna Müller-Leisse
    Jan D. Schmitto
    Christian Veltmann
    David Duncker
    Journal of Interventional Cardiac Electrophysiology, 2021, 60 : 303 - 311
  • [42] Eligibility for subcutaneous implantable cardioverter-defibrillator in patients with left ventricular assist device
    Zormpas, Christos
    Eiringhaus, Joerg
    Hillmann, Henrike A. K.
    Hohmann, Stephan
    Mueller-Leisse, Johanna
    Schmitto, Jan D.
    Veltmann, Christian
    Duncker, David
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 60 (02) : 303 - 311
  • [43] IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS IN PATIENTS WITH LEFT VENTRICULAR NONCOMPACTION
    Sousa, O.
    Dias Ferreira, N.
    Pereira, E.
    Adao, L.
    Oliveira, M.
    Goncalves, H.
    Primo, J.
    Ribeiro, J.
    Fonseca, C.
    Gama, V.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 : S155 - S155
  • [44] Implantable cardioverter-defibrillators in patients with left ventricular noncompaction
    Kobza, Richard
    Jenni, Rolf
    Erne, Paul
    Oechslin, Erwin
    Duru, Firat
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (04): : 461 - 467
  • [45] Emerging electromagnetic interferences between implantable cardioverter-defibrillators and left ventricular assist devices: Authors' reply
    Caliskan, Kadir
    Theuns, Dominic A. M. J.
    Szili-Torok, Tamas
    EUROPACE, 2020, 22 (12): : 1911 - 1912
  • [46] Ventricular Arrhythmias and Sudden Cardiac Death in Left Ventricular Assist Device Patients Without Implantable Cardioverter Defibrillators
    Gokhale, Sanket
    Malesz, Alexandra
    Masha, Luke
    ASAIO JOURNAL, 2024, 70 (09) : 773 - 777
  • [47] IMPLANTABLE CARDIOVERTER DEFIBRILLATOR IMPLANTATION IMPROVES OUTCOME OF PATIENTS WITH LEFT VENTRICULAR ASSIST DEVICES
    Agrawal, Sahil
    Nanda, Sudip
    Garg, Lohit
    Manda, Yugandhar
    Singh, Amitoj
    Sinha, Archana
    Vefali, Huseng
    Quddus, Abdullah
    Shirani, Jamshid
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 1269 - 1269
  • [48] Implantable Cardioverter Defibrillator Utilization and Programming among Patients with Left Ventricular Assist Devices
    Kiehl, Erich L.
    Joseph, Susan
    Agarwal, Rahul
    Nabutovsky, Yelena
    Cantillon, Daniel J.
    JOURNAL OF CARDIAC FAILURE, 2017, 23 (08) : S21 - S22
  • [49] Left Ventricular Assist Device in a Patient With a Concomitant Subcutaneous Implantable Cardioverter Defibrillator
    Saeed, Diyar
    Albert, Alexander
    Westenfeld, Ralf
    Maxhera, Bujar
    Gramsch-Zabel, Hildegard
    O'Connor, Stephen
    Lichtenberg, Artur
    Winter, Joachim
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (03): : E32 - E33
  • [50] The Role of Implantable Cardioverter-Defibrillators in Patients With Continuous Flow Left Ventricular Assist Devices (vol 6, pg 668, 2013)
    Enriquez
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2014, 7 (01): : 185 - 185