Subcutaneous implantable cardioverter defibrillators in patients with left ventricular assist devices: case report and comprehensive review

被引:10
|
作者
Lopez-Gil, Maria [1 ,2 ]
Fontenla, Adolfo [1 ,2 ]
Delgado, Juan F. [2 ,3 ,4 ,5 ]
Rodriguez-Munoz, Daniel [1 ]
机构
[1] 12 Octubre Univ Hosp, Cardiol Dept, Cardiac Electrophysiol & Arrhythmia Unit, Avda Cordoba S-N, Madrid 28041, Spain
[2] 12 Octubre Univ Hosp, Avda Cordoba S-N, Madrid 28041, Spain
[3] 12 Octubre Univ Hosp, Cardiol Dept, Heart Failure & Heart Transplantat Program, Avda Cordoba S-N, Madrid 28041, Spain
[4] Univ Complutense, Fac Med, Avda Seneca 2, Madrid 28040, Spain
[5] CIBER CV, C Melchor Fernandez Almagro 3, Madrid 28029, Spain
关键词
Left ventricular assist devices; Subcutaneous implantable cardioverter defibrillator; Electromagnetic interferences; Undersensing; Case report; ELECTRONIC DEVICES;
D O I
10.1093/ehjcr/ytz057
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Left ventricular assist devices (LVAD) are increasingly used in patients with advanced heart failure, many of whom have been or will be implanted with an implantable cardioverter defibrillator (ICD). Interaction between both devices is a matter of concern. Subcutaneous ICD (S-ICD) obtains its signals through subcutaneous vectors, which poses special challenges with regards to adequate performance following LVAD implantation. Case summary We describe the case of a 24-year-old man implanted with an S-ICD because of idiopathic dilated cardiomyopathy, severe biventricular dysfunction, and self-limiting sustained ventricular tachycardias. After the implantation of a HeartMate 3TM (Left Ventricular Assist System, Abbott) several months later, the S-ICD became useless because of inappropriate sensing due to electromagnetic interference and attenuation of QRS voltage. Discussion We reviewed the reported cases in PubMed about the concomitant use of S-ICD and LVAD. Seven case reports about the performance of S-ICD in patients with an LVAD were identified, with discordant results. From these articles, we analyse the potential causes for these differing results. Pump location and operating rates in LVAD, as well as changes in the subcutaneous-electrocardiogram detected by the S-ICD after LVAD implantation are related to sensing disturbances when used in the same patient.
引用
下载
收藏
页数:6
相关论文
共 50 条
  • [21] Occurrence of ventricular tachyarrhythmias in left ventricular assist devices patients with implantable defibrillators
    Sasov, M.
    Lesny, P.
    Svetlosak, M.
    Margitfalvi, P.
    Hatala, R.
    Goncalvesova, E.
    EUROPEAN JOURNAL OF HEART FAILURE, 2018, 20 : 401 - 401
  • [22] Implantable cardioverter defibrillators in left ventricular assist device patients: A systematic review and meta-analysis
    Rorris, Filippos-Paschalis
    Antonopoulos, Constantine N.
    Kyriakopoulos, Christos P.
    Drakos, Stavros G.
    Charitos, Christos
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2021, 40 (10): : 1098 - 1106
  • [23] Emerging electromagnetic interferences between implantable cardioverter-defibrillators and left ventricular assist devices
    Yalcin, Yunus C.
    Kooij, Claudette
    Theuns, Dominic A. M. J.
    Constantinescu, Alina A.
    Brugts, Jasper J.
    Manintveld, Olivier C.
    Yap, Sing-Chien
    Szili-Torok, Tamas
    Bogers, Ad J. J. C.
    Caliskan, Kadir
    EUROPACE, 2020, 22 (04): : 584 - 587
  • [24] PROPHYLACTIC IMPLANTABLE CARDIOVERTER DEFIBRILLATORS IN PATIENTS WITH CONTINUOUS FLOW LEFT VENTRICULAR ASSIST DEVICES: ARE THEY COST-EFFECTIVE?
    Chatur, Safia
    Chew, Derek
    Sharma, Nakul
    Church, Mathew
    Raj, Satish R.
    Manns, Braden
    Wilton, Stephen
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 3076 - 3076
  • [25] Outcomes in Patients with Left Ventricular Assist Devices, Pacemakers, and Implantable Cardioverter Defibrillators Undergoing Single Balloon Enteroscopy
    Patel, Brijesh
    Shiani, Ashok
    Rodriguez, Andrea C.
    Lipka, Seth
    Davis-Yadley, Ashley H.
    Nelson, Kirbylee K.
    Rabbanifard, Roshanak
    Kumar, Ambuj
    Brady, Patrick G.
    SOUTHERN MEDICAL JOURNAL, 2019, 112 (02) : 130 - 134
  • [26] Simultaneous Use of Implantable Cardioverter-Defibrillators and Left Ventricular Assist Devices in Patients With Severe Heart Failure
    Kuehne, Michael
    Sakumura, Michaela
    Reich, Stephen Scott
    Sarrazin, Jean-Francois
    Wells, Darryl
    Chalfoun, Nagib
    Crawford, Thomas
    Boonyapisit, Warangkna
    Horwood, Laura
    Chugh, Aman
    Good, Eric
    Jongnarangsin, Krit
    Bogun, Frank
    Oral, Hakan
    Morady, Fred
    Pagani, Francis
    Pelosi, Frank, Jr.
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 105 (03): : 378 - 382
  • [27] Role of Implantable Cardioverter-Defibrillators in Patients With Continuous Flow Ventricular Assist Devices
    Boilson, Barry A.
    Friedman, Paul A.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (04): : 663 - 665
  • [28] Wearable cardioverter defibrillator: bridging for implantable defibrillators in left ventricular assist device patients
    Rorris, Filippos-Paschalis
    Charitos, Christos
    HEART FAILURE REVIEWS, 2021, 26 (04) : 763 - 765
  • [29] Implantable Cardioverter-Defibrillators Are Not Associated with Survival in Patients with a Left Ventricular Assist Device
    Sayer, Gabriel T.
    Bhat, Geetha
    Gallagher, Colleen
    Macaluso, Gregory
    Cotts, William
    Tatooles, Antone
    Spear, William
    JOURNAL OF CARDIAC FAILURE, 2013, 19 (08) : S58 - S58
  • [30] Wearable cardioverter defibrillator: bridging for implantable defibrillators in left ventricular assist device patients
    Filippos-Paschalis Rorris
    Christos Charitos
    Heart Failure Reviews, 2021, 26 : 763 - 765