Precise measurement of uranium isotope ratios in Fukushima soils using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)

被引:10
|
作者
Murugan, Rajamanickam [1 ]
Veerasamy, Nimelan [1 ,2 ]
Zhao, Ye [3 ]
Aono, Tatsuo [1 ]
Sahoo, Sarata Kumar [1 ]
机构
[1] Natl Inst Quantum & Radiol Sci & Technol QST, Environm Radionuclide Res Grp, 4-9-1 Anagawa, Chiba 2638555, Japan
[2] Inst Environm Sci, Environm Impact Res Dept, 1-7 Ienomae, Aomori 0393212, Japan
[3] Nu Instruments Ltd, Unit 74, Clywedog Rd South, Wrexham LL13 9XS, Wales
关键词
MC-ICP-MS; Daly detector; U-234/U-238; U-235/U-238; Fukushima soil sample; UTEVA resin; SILICATE ROCK SAMPLES; ENVIRONMENTAL-SAMPLES; THORIUM; OPTIMIZATION; SEPARATION; PLUTONIUM;
D O I
10.1016/j.ijms.2021.116623
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Precise measurement of U-234/U-238 and U-235/U-238 isotope ratios was performed using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) in this study. The U-234 ions were measured using a Daly detector, the U-235 ions were measured using a Faraday cup with a 10(12) Omega resistor, and the U-238 ions were measured using a Faraday cup with the usual 10(11) Omega resistor. Chemical separation of uranium was carried out by three different methods using either combinations of anion exchange and UTEVA resins or UTEVA resin three times. Chromatography combining three UTEVA resin columns provided the highest recovery (%) of uranium and biggest improvement in precise measurements of uranium isotope ratios. The certificate reference material (CRM) JLk-1 was used as an in-house standard for the uranium isotope ratio measurements. The long-term reproducibility of the in-house standard was 0.60% for U-234/U-238 and 0.05% for U-235/U-238. The measured ratios were compared with the natural ratios, and the relative deviation obtained for uranium isotope ratios was less than 0.005% for U-234/U-238 and U-235/U-238. Finally, the present method was applied to measure uranium isotope ratios in Fukushima microwave-digested soil samples. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Precise measurement of stable potassium isotope ratios using a single focusing collision cell multi-collector ICP-MS
    Li, Weiqiang
    Beard, Brian L.
    Li, Shilei
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (04) : 1023 - 1029
  • [32] In-situ precise isotopic analysis of tungsten using laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) with time resolved data acquisition
    Hirata, T
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (03) : 204 - 210
  • [33] Influence of room temperature on magnesium isotope measurements by multi-collector inductively coupled plasma mass spectrometry
    Zhang, Xing-Chao
    Zhang, An-Yu
    Zhang, Zhao-Feng
    Huang, Fang
    Yu, Hui-Min
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2018, 32 (13) : 1026 - 1030
  • [34] Isotope fractionation during ion beam formation in multi-collector inductively coupled plasma mass spectrometry
    Kivel, Niko
    Guenther-Leopold, Ines
    Vanhaecke, Frank
    Guenther, Detlef
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 76 : 126 - 132
  • [35] Determination of Uranium Isotope Ratios in Uranium Particles by Laser Ablation Multiple Collector Inductively Coupled Plasma Mass Spectrometry
    Wang Wei
    Li Zhi-Ming
    Xu Jiang
    Zhou Guo-Qing
    Shen Xiao-Pan
    Zhai Li-Hua
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (05) : 703 - 708
  • [36] Determination of Stable Silicon Isotopes Using Multi-Collector Inductively Coupled Plasma Mass Spectrometry
    Zhang An-Yu
    Zhang Jing
    Zhang Rui-Feng
    Xue Yun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (09) : 1353 - 1358
  • [37] Precise analysis of potassium isotopic composition in plant materials by multi-collector inductively coupled plasma mass spectrometry
    He, Mao-Yong
    Ren, Tong Xiang
    Jin, Zhang Dong
    Deng, Li
    Liu, Hai Jiao
    Cheng, Yuan Yuan
    Li, Zheng Yan
    Liu, Xing Xing
    Yang, Yang
    Chang, Hong
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2023, 209
  • [38] DETERMINATION OF LEAD ISOTOPE RATIOS BY INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS)
    LONGERICH, HP
    FRYER, BJ
    STRONG, DF
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (1-2) : 39 - 48
  • [39] Isotope Ratio Analysis of Lead in Blood and Environmental Samples by Multi-collector Inductively Coupled Plasma Mass Spectrometry
    Takagi, Mai
    Yoshinaga, Jun
    Tanaka, Atsushi
    Seyama, Haruhiko
    ANALYTICAL SCIENCES, 2011, 27 (01) : 29 - 35
  • [40] Isotope Ratio Analysis of Lead in Blood and Environmental Samples by Multi-collector Inductively Coupled Plasma Mass Spectrometry
    Mai Takagi
    Jun Yoshinaga
    Atsushi Tanaka
    Haruhiko Seyama
    Analytical Sciences, 2011, 27 : 29 - 35