Real-time monitoring of skin wound healing on nano-grooves topography using electric cell-substrate impedance sensing (ECIS)

被引:32
|
作者
Cui, Yao [1 ]
An, Yu [1 ]
Jin, Tongyu [1 ]
Zhang, Fan [1 ]
He, Pingang [1 ]
机构
[1] East China Normal Univ, Sch Chem & Mol Engn, Shanghai 200241, Peoples R China
关键词
Skin wound healing; Nano-grooves topography; ECIS; Cell migration; Cell proliferation; MAMMALIAN-CELLS; IN-VITRO; GUIDANCE; REGENERATION; SPECTROSCOPY; BIOSENSORS; MIGRATION; ALIGNMENT; SURFACES; MOTILITY;
D O I
10.1016/j.snb.2017.04.183
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Skin wound healing represents a critical medical topic. For its ideal case, the injured tissue can repair quickly without scars. In this paper, an ECIS device was developed using nano-grooves to simulate internal extracellular matrix (ECM) with 75 nm in depth and 200 nm in width of grooves and ridges. HFF and HaCaT cells were cultured but only HFF cells could orient along the nano-grooves. In the cell migration and proliferation occurred during the wound healing, HFF and HaCaT cells both presented increased normalized impedance (NI) values at the characteristic frequencies of 977 Hz and.1465 Hz, respectively. Compared to flat electrodes, nano-grooves electrodes generated less intense impedance signals in HFF cell migration and proliferation, and HaCaT cell migration, but more intense ones in HaCaT cell proliferation. Cell images were captured simultaneously and the statistical analysis demonstrated that the nano-grooves electrode could accelerate the migration while slow down the proliferation. After establishing the correlations between impedance response and cell behaviors, it could be found that the NI values increased all linearly the rising of recovery degree and cell number. Under the equal changes of recovery degree and cell number on nano-grooves, HFF cells produced the both declined impedance signals, because of the elongation, while, HaCaT cells created the same and deduced NI variation rates, due to the unchanged morphology and aggregation growth, respectively. Our work provides a useful approach for the clinical monitoring of skin wound healing in a real-time and label-free manner, potentially promoting the development of regenerative medicine. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:461 / 468
页数:8
相关论文
共 50 条
  • [41] The Effect of ABO Immune Complexes on Endothelial Cell Integrity As Measured By Electric Cell-Substrate Impedance Sensing (ECIS) and Confocal Microscopy
    McRae, Hannah L.
    Slavin, Spencer
    Rahman, Arshad
    Blumberg, Neil
    Refaai, Majed A.
    [J]. BLOOD, 2017, 130
  • [42] Towards the Electric Cell-Substrate Impedance Sensing (ECIS) Technique as a Monitor of Effects in Magnetic Field Exposure Experiments In Vitro
    Makinistian, L.
    Marelli, B. E.
    Ortega, H. H.
    [J]. VI LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING (CLAIB 2014), 2014, 49 : 27 - 30
  • [43] Assessment of cytotoxicity using electric cell-substrate impedance sensing: Concentration and time response function approach
    Xiao, CD
    Lachance, B
    Sunahara, G
    Luong, JHT
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (22) : 5748 - 5753
  • [44] Use of electric cell-substrate impedance sensing as a tool for quantifying cytopathic effect in influenza A virus infected MDCK cells in real-time
    McCoy, MH
    Wang, E
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2005, 130 (1-2) : 157 - 161
  • [45] Electric Cell-Substrate Impedance Sensing (ECIS) as a Platform for Evaluating Barrier-Function Susceptibility and Damage from Pulmonary Atelectrauma
    Yamaguchi, Eiichiro
    Yao, Joshua
    Aymond, Allison
    Chrisey, Douglas B.
    Nieman, Gary F.
    Bates, Jason H. T.
    Gaver, Donald P.
    [J]. BIOSENSORS-BASEL, 2022, 12 (06):
  • [46] Electric Cell-Substrate Sensing for Real-Time Evaluation of Metal-Organic Framework Toxicological Profiles
    Rose, Olivia L.
    Arnold, Myra
    Dinu, Cerasela-Zoica
    [J]. JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (195):
  • [47] EVALUATION OF MICROMOTION OF VASCULAR ENDOTHELIAL CELLS IN ELECTRICAL CELL-SUBSTRATE IMPEDANCE SENSING (ECIS) METHOD USING A MATHEMATICAL MODEL
    Goda, Noriko
    Kataoka, Noriyuki
    Shimizu, Juichiro
    Mohri, Satoshi
    Yamamoto, Yoshitake
    Okuda, Hiroyuki
    Kajiya, Fumihiko
    [J]. JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2005, 5 (02) : 357 - 368
  • [48] Quantitative Evaluation of Effect for Radiation Exposure to Cultured Cells Using Electrical Cell-substrate Impedance Sensing (ECIS) Method
    Yamamoto, Y.
    Goda, N.
    Nakamura, T.
    Kusuhara, T.
    Maruyama, T.
    Mohri, S.
    Kataoka, N.
    Kajiya, F.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1914 - +
  • [49] Monitoring Intestinal Organoid-Derived Monolayer Barrier Functions with Electric Cell-Substrate Impedance Sensing (ECIS) ( vol 14 , e5064 , 2024)
    Ouahoud, Sarah
    Giugliano, Francesca P.
    Muncan, Vanesa
    [J]. BIO-PROTOCOL, 2024, 14 (15):
  • [50] The Study of Cell Attachment and Spreading on Polyaniline and Gelatin using Electric Cell-substrate Impedance Sensing
    Ibrahim, Irmanisha
    Nordin, Anis Nurashikin
    Hashim, Yumi Zuhanis Has-Yun
    [J]. JOURNAL OF PURE AND APPLIED MICROBIOLOGY, 2014, 8 : 827 - 831