Real-time monitoring of skin wound healing on nano-grooves topography using electric cell-substrate impedance sensing (ECIS)

被引:32
|
作者
Cui, Yao [1 ]
An, Yu [1 ]
Jin, Tongyu [1 ]
Zhang, Fan [1 ]
He, Pingang [1 ]
机构
[1] East China Normal Univ, Sch Chem & Mol Engn, Shanghai 200241, Peoples R China
关键词
Skin wound healing; Nano-grooves topography; ECIS; Cell migration; Cell proliferation; MAMMALIAN-CELLS; IN-VITRO; GUIDANCE; REGENERATION; SPECTROSCOPY; BIOSENSORS; MIGRATION; ALIGNMENT; SURFACES; MOTILITY;
D O I
10.1016/j.snb.2017.04.183
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Skin wound healing represents a critical medical topic. For its ideal case, the injured tissue can repair quickly without scars. In this paper, an ECIS device was developed using nano-grooves to simulate internal extracellular matrix (ECM) with 75 nm in depth and 200 nm in width of grooves and ridges. HFF and HaCaT cells were cultured but only HFF cells could orient along the nano-grooves. In the cell migration and proliferation occurred during the wound healing, HFF and HaCaT cells both presented increased normalized impedance (NI) values at the characteristic frequencies of 977 Hz and.1465 Hz, respectively. Compared to flat electrodes, nano-grooves electrodes generated less intense impedance signals in HFF cell migration and proliferation, and HaCaT cell migration, but more intense ones in HaCaT cell proliferation. Cell images were captured simultaneously and the statistical analysis demonstrated that the nano-grooves electrode could accelerate the migration while slow down the proliferation. After establishing the correlations between impedance response and cell behaviors, it could be found that the NI values increased all linearly the rising of recovery degree and cell number. Under the equal changes of recovery degree and cell number on nano-grooves, HFF cells produced the both declined impedance signals, because of the elongation, while, HaCaT cells created the same and deduced NI variation rates, due to the unchanged morphology and aggregation growth, respectively. Our work provides a useful approach for the clinical monitoring of skin wound healing in a real-time and label-free manner, potentially promoting the development of regenerative medicine. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:461 / 468
页数:8
相关论文
共 50 条
  • [21] Electric Cell-Substrate Impedance Sensing (ECIS) with Microelectrode Arrays for Investigation of Cancer Cell - Fibroblasts Interaction
    Trong Binh Tran
    Baek, Changyoon
    Min, Junhong
    [J]. PLOS ONE, 2016, 11 (04):
  • [22] Comparison of Fish and Mammalian Cell Line Responses to Multiple Chemicals Using Electric Cell-Substrate Impedance Sensing (ECIS)
    Brennan, Linda
    Widder, Mark
    van der Schalie, William
    [J]. IN VITRO CELLULAR & DEVELOPMENTAL BIOLOGY-ANIMAL, 2010, 46 : S101 - S101
  • [23] Real-Time Monitoring of the Cytotoxic and Antimetastatic Properties of Cannabidiol in Human Oral Squamous Cell Carcinoma Cells Using Electric Cell-Substrate Impedance Sensing
    Huang, Chien-Chu
    Chiu, Shao-Chih
    Chao, Shih-Chi
    Liao, Heng-Yi
    Lee, Shiao-Pieng
    Huang, Chun-Chung
    Cho, Der-Yang
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (24)
  • [24] Real-time quantitative monitoring of hiPSC-based model of macular degeneration on Electric Cell-substrate Impedance Sensing microelectrodes
    Gamal, W.
    Borooah, S.
    Smith, S.
    Underwood, I.
    Srsen, V.
    Chandran, S.
    Bagnaninchi, P. O.
    Dhillon, B.
    [J]. BIOSENSORS & BIOELECTRONICS, 2015, 71 : 445 - 455
  • [25] Real-time label-free monitoring of adipose-derived stem cell differentiation with electric cell-substrate impedance sensing
    Bagnaninchi, Pierre O.
    Drummond, Nicola
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2011, 108 (16) : 6462 - 6467
  • [26] Online Measurement of Real-Time Cytotoxic Responses Induced by Multi-Component Matrices, such as Natural Products, through Electric Cell-Substrate Impedance Sensing (ECIS)
    Fallarero, Adyary
    Batista-Gonzalez, Ana E.
    Hiltunen, Anna K.
    Liimatainen, Jaana
    Karonen, Maarit
    Vuorela, Pia M.
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2015, 16 (11): : 27044 - 27057
  • [27] Real-time monitoring primary cardiomyocyte adhesion based on electrochemical impedance spectroscopy and electrical cell-substrate impedance sensing
    Qiu, Yiling
    Liao, Ronglih
    Zhang, Xin
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (04) : 990 - 996
  • [28] Dissecting the extravasation process of metastatic breast cancer cells using an Electric Cell-Substrate Impedance Sensing (ECIS) assay
    Price, Janet E.
    Newsham, Irene F.
    [J]. CLINICAL & EXPERIMENTAL METASTASIS, 2007, 24 (04) : 276 - 277
  • [29] Electric cell-substrate impedance sensing (ECIS) as a noninvasive means to monitor the kinetics of cell spreading to artificial surfaces
    Wegener, J
    Keese, CR
    Giaever, I
    [J]. EXPERIMENTAL CELL RESEARCH, 2000, 259 (01) : 158 - 166
  • [30] Monitoring viral-induced cell death using electric cell-substrate impedance sensing
    Campbell, Carmen Elaine
    Laane, Morten Motzfeldt
    Haugarvoll, Erlend
    Giaever, Ivar