Validation of A&D UA-767 device for the self-measurement of blood pressure

被引:82
|
作者
Rogoza, AN [1 ]
Pavlova, TS [1 ]
Sergeeva, MV [1 ]
机构
[1] Dept New Diagnost Methods, Moscow 121552, Russia
关键词
A&D UA-767; self blood pressure measurement; validation; AAMI and BHS protocol;
D O I
10.1097/00126097-200008000-00006
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background The validation of self-measurement devices has been recommended. Automatic monitor A & D UA-767 (A&D Company, Ltd, Tokyo, Japan) is well known and widely used, but not tested according to the Association for Advancement of Medical Instrumentation (AAMI) and British Hypertension Society (BHS) recommendations. Objective To perform a clinical validation for use by adults of the A&D UA-767 device according to the criteria of the AAMI and a modified BHS protocol. Methods The test concerned 101 subjects (57 men and 44 women) aged 15-85 years with arm circumferences of 22-39 cm, a systolic blood pressure (SBP) range of 89-206 mmHg, and a diastolic blood pressure (DBP) range of 53 - 122 mmHg. For each subject, three readings of the UA-767 were compared with simultaneous auscultatory measurements by two trained independent observers who used a mercury manometer and dual stethoscope. The results were graded according to the BHS (1990 and 1993) and AAMI recommendations. Results Observers showed close agreement, with mean differences of 1.1. +/- 2.4 mmHg for SEP and -0.7 +/- 2.0 mmHg for DBP. The proportion of Values agreeing to within 5, 10 and 15 mmHg were 93, 100, and 100% for SEP and 97, 100, and 100% for DBP for the two observers. The sphygmomanometer measurements were 132 +/- 24/79 +/- 14 mmHg (mean +/- SD). The average difference between the mercury sphygmomanometer and A&D UA-767 readings for SEP and DBP were, respectively, - 0.4 +/- 5.4 and -0.4 +/- 4.8 mmHg. The proportion of values agreeing to within 5,10, and 15 mmHg were 82, 94, and 98% for SEP and 80, 95, and 98% for DBP for the observers and device (A/A grade for BHS). Conclusions For an adult population, the A&D UA-767 device for the self-measurement of blood pressure satisfied the AAMI criteria, achieved a BHS grade of A/A and can therefore be recommended for monitoring blood pressure in home and clinical conditions by patients with mild-to-moderate arterial hypertension. (C) 2000 Lippincott Williams & Wilkins.
引用
收藏
页码:227 / 231
页数:5
相关论文
共 50 条
  • [1] Validation of UA-767 plus device for self-measurement of blood pressure
    Kobalava, ZD
    Kotovskaia, IV
    Rusakova, OS
    Babaeva, LA
    AMERICAN JOURNAL OF HYPERTENSION, 2004, 17 (05) : 48A - 48A
  • [2] Validation of the A&D UA-774 (UA-767Plus) device for self-measurement of blood pressure
    Verdecchia, P
    Angeli, F
    Poeta, F
    Reboldi, GP
    Borgioni, C
    Pittavini, L
    Porcellati, C
    BLOOD PRESSURE MONITORING, 2004, 9 (04) : 225 - 229
  • [3] Validation of the A&D UA-705 device for self-measurement of blood pressure according to the British Hypertension Society protocol
    Verdecchia, Paolo
    Angeli, Fabio
    Gattobigio, Roberto
    Angeli, Enrica
    Pede, Silvia
    Pittavini, Loretta
    BLOOD PRESSURE MONITORING, 2006, 11 (04) : 223 - 227
  • [4] Validation of A&D UA-85X device for blood pressure measurement
    Bonso, Elisa
    Ragazzo, Fabio
    Palatini, Paolo
    BLOOD PRESSURE MONITORING, 2008, 13 (06) : 339 - 341
  • [5] Evaluation of the A&D UA-767 and Welch Allyn Spot Vital Signs noninvasive blood pressure monitors using a blood pressure simulator
    P D Davis
    J L Dennis
    R Railton
    Journal of Human Hypertension, 2005, 19 : 197 - 203
  • [6] Evaluation of the A&D UA-767 and Welch Allyn Spot Vital Signs noninvasive blood pressure monitors using a blood pressure simulator
    Davis, PD
    Dennis, JL
    Railton, R
    JOURNAL OF HUMAN HYPERTENSION, 2005, 19 (03) : 197 - 203
  • [7] Validation of the A&D UA-631 (UA-779 Life Source) device for self-measurement of blood pressure and relationship between its performance and large artery compliance
    Longo, D
    Bertolo, O
    Toffanin, G
    Frezza, P
    Palatini, P
    BLOOD PRESSURE MONITORING, 2002, 7 (04) : 243 - 248
  • [8] Validation of semi-automatic device UA-704 for self-measurement of blood pressure
    Kobalava, ZD
    Kotovskaya, YV
    Rodionov, EV
    AMERICAN JOURNAL OF HYPERTENSION, 2005, 18 (05) : 36A - 36A
  • [9] Validation of semi-automatic device UA-704 for self-measurement of blood pressure
    Kobalava, ZD
    Kotovskaya, YV
    Rodionov, E
    BLOOD PRESSURE MONITORING, 2005, 10 (04) : 223 - 225
  • [10] Validation of the A&D wrist-cuff UB-511 (UB-512) device for self-measurement of blood pressure
    Angeli, Fabio
    Sardone, Mariagrazia
    Angeli, Enrica
    Repaci, Salvatore
    Gattobigio, Roberto
    Verdecchia, Paolo
    BLOOD PRESSURE MONITORING, 2006, 11 (06) : 349 - 354