The calibration of 3-axis magnetic sensor array system for tracking wireless capsule endoscope

被引:39
|
作者
Hu, Chao [1 ,2 ]
Meng, Max Q. -H. [3 ]
Mandal, Mrinal [2 ]
机构
[1] Ningbo Univ, Dept Elect Eng & Automat, Ningbo, Peoples R China
[2] Univ Alberta, Dept ECE, Edmonton, AB T6G 2M7, Canada
[3] Chinese Univ Hong Kong, Dept EE, Shatin, Peoples R China
关键词
calibration; magnetic localization and orientation; real time tracking; wireless capsule endoscope;
D O I
10.1109/IROS.2006.282118
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A magnetic localization and orientation system is proposed for tracking wireless capsule endoscope. This system uses a small magnet enclosed in the capsule to serve as excitation source. When the capsule moves, the magnet establishes a static magnetic field around. With the magnetic sensor array composed of Honeywell 3-axis magnetic sensors, HMC1053, the magnetic intensities in some pre-determined spatial points can be detected, and the magnet's position and orientation parameters can be computed based on an algorithm. To initiate the system and obtain better tracking accuracy, we propose a calibration technique for the magnetic tracking system. The calibration includes sensitivity determination and nonlinearity adjustment, sensor center position and orientation adjustment. Based on the calibration procedures, the system can achieve satisfactory tracking accuracy with the average localization error 3.3 mm and the average orientation error 3.0 degrees.
引用
收藏
页码:162 / +
页数:2
相关论文
共 50 条
  • [41] MECHANISM FOR 3-AXIS CONTROL OF AN ION THRUSTER ARRAY
    PERKINS, GS
    JOHNSON, KG
    MASEK, TD
    FERRERA, JD
    JOURNAL OF SPACECRAFT AND ROCKETS, 1972, 9 (03) : 218 - &
  • [42] A 3-Axis Antenna Array for Polarimetric Spectrum Surveys
    Allen, J. Wayde
    2012 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC), 2012, : 575 - 578
  • [43] Free Sensor Array based Relative Localization System for Wireless Capsule Endoscopy
    Xu, Yangxin
    Meng, Max Q. -H.
    2018 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2018, : 550 - 555
  • [44] A CONTINUOUS AND WEARABLE BLOOD PRESSURE MEASUREMENT DEVICE WITH MEMS 3-AXIS FORCE SENSOR ARRAY
    Dohi, Tetsuji
    Urata, Hisashi
    Fukahori, Shun
    Hori, Masataka
    Nakai, Akihito
    Nakamura, Hiroyuki
    2019 20TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS & EUROSENSORS XXXIII (TRANSDUCERS & EUROSENSORS XXXIII), 2019, : 2182 - 2184
  • [45] A skin-inspired optoelectromechanically coupled system for 3-axis airflow sensor
    Wu, Xiaozhong
    Zhang, Ziyu
    Zhao, Haonan
    Wang, Yang
    Zhou, Junjie
    Meng, Deyu
    He, Yanle
    Liu, Min
    Zhang, Yifei
    Xue, Zhongying
    Jiang, Chengming
    Zhang, Miao
    Di, Zengfeng
    Mei, Yongfeng
    Guo, Qinglei
    NANO ENERGY, 2025, 135
  • [46] A 3-Axis Miniature Magnetic Sensor Based on a Planar Fluxgate Magnetometer with an Orthogonal Fluxguide
    Lu, Chih-Cheng
    Huang, Jeff
    SENSORS, 2015, 15 (06) : 14727 - 14744
  • [47] Navigation of a robotic capsule endoscope with a novel ultrasound tracking system
    Jan D. J. Gumprecht
    Tim C. Lueth
    Mir Behrad Khamesee
    Microsystem Technologies, 2013, 19 : 1415 - 1423
  • [48] A Capsule Endoscope System for Wide Visualization Field and Location Tracking
    Jang, Jaeeun
    Yoo, Hoi-Jun
    2018 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS): ADVANCED SYSTEMS FOR ENHANCING HUMAN HEALTH, 2018, : 583 - 586
  • [49] Navigation of a robotic capsule endoscope with a novel ultrasound tracking system
    Gumprecht, Jan D. J.
    Lueth, Tim C.
    Khamesee, Mir Behrad
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2013, 19 (9-10): : 1415 - 1423
  • [50] Control strategy of active actuation system of wireless capsule endoscope
    Hu, Chao
    Chen, Dongmei
    Wang, Lei
    Meng, Max Q. -H.
    2007 IEEE INTERNATIONAL CONFERENCE ON INTEGRATION TECHNOLOGY, PROCEEDINGS, 2007, : 1 - +