The calibration of 3-axis magnetic sensor array system for tracking wireless capsule endoscope

被引:39
|
作者
Hu, Chao [1 ,2 ]
Meng, Max Q. -H. [3 ]
Mandal, Mrinal [2 ]
机构
[1] Ningbo Univ, Dept Elect Eng & Automat, Ningbo, Peoples R China
[2] Univ Alberta, Dept ECE, Edmonton, AB T6G 2M7, Canada
[3] Chinese Univ Hong Kong, Dept EE, Shatin, Peoples R China
关键词
calibration; magnetic localization and orientation; real time tracking; wireless capsule endoscope;
D O I
10.1109/IROS.2006.282118
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A magnetic localization and orientation system is proposed for tracking wireless capsule endoscope. This system uses a small magnet enclosed in the capsule to serve as excitation source. When the capsule moves, the magnet establishes a static magnetic field around. With the magnetic sensor array composed of Honeywell 3-axis magnetic sensors, HMC1053, the magnetic intensities in some pre-determined spatial points can be detected, and the magnet's position and orientation parameters can be computed based on an algorithm. To initiate the system and obtain better tracking accuracy, we propose a calibration technique for the magnetic tracking system. The calibration includes sensitivity determination and nonlinearity adjustment, sensor center position and orientation adjustment. Based on the calibration procedures, the system can achieve satisfactory tracking accuracy with the average localization error 3.3 mm and the average orientation error 3.0 degrees.
引用
收藏
页码:162 / +
页数:2
相关论文
共 50 条
  • [31] Small Antenna with Magnetic Sheet for Wireless Capsule Endoscope Communication
    Yokoyama, Yutaro
    Saito, Kazuyuki
    Peng, Yunxiao
    Ito, Koichi
    2020 INTERNATIONAL WORKSHOP ON ANTENNA TECHNOLOGY (IWAT), 2020,
  • [32] Calibration of a 3-axis Hemispherical Resonator Gyro Assembly
    Golovan, Andrey
    Kozlov, Alexander
    Tarygin, Ilya
    PROCEEDINGS OF 8TH INTERNATIONAL CONFERENCE ON RECENT ADVANCES IN SPACE TECHNOLOGIES (RAST 2017), 2017, : 393 - 396
  • [33] An Improved Magnetic Localization and Orientation Algorithm for Wireless Capsule Endoscope
    Hu, Chao
    Yang, Wanan
    Chen, Dongmei
    Meng, Max Q. -H.
    Dai, Houde
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 2055 - 2058
  • [34] Robotic Localization Based on Planar Cable Robot and Hall Sensor Array Applied to Magnetic Capsule Endoscope
    Kim, Min-Cheol
    Kim, Eui-Sun
    Park, Jong-Oh
    Choi, Eunpyo
    Kim, Chang-Sei
    SENSORS, 2020, 20 (20) : 1 - 18
  • [35] MEMS 3-AXIS INERTIAL SENSOR PROCESS
    Dempwolf, Sophia
    Knechtel, Roy
    2013 SYMPOSIUM ON DESIGN, TEST, INTEGRATION AND PACKAGING OF MEMS/MOEMS (DTIP), 2013,
  • [36] Advanced Calibration Method for 3-Axis MEMS Accelerometers
    Gheorghe, Marius V.
    2016 39TH INTERNATIONAL SEMICONDUCTOR CONFERENCE (CAS), 2016, : 81 - 84
  • [37] Gradient Methodology for 3-Axis Accelerometer Static Calibration
    Draganova, Katarina
    Lassak, Miroslav
    Lipovsky, Pavol
    Kan, Viktor
    Kliment, Tomas
    INTERNATIONAL CONFERENCE ON MILITARY TECHNOLOGIES (ICMT 2015), 2015, : 521 - 525
  • [38] GRADIENT METHODOLOGY FOR 3-AXIS MAGNETOMETER SCALAR CALIBRATION
    Kliment, Tomas
    Praslicka, Dusan
    Draganova, Katarina
    Blazek, Josef
    Journal of Electrical Engineering-Elektrotechnicky Casopis, 2015, 66 (07): : 157 - 160
  • [39] A Wearable, Reconfigurable, and Modular Magnetic Tracking System for Wireless Capsule Robots
    Su, Shijian
    Yuan, Sishen
    Li, Zhen
    Ma, Yan
    Ma, Miaomiao
    Ren, Hongliang
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2024, 20 (12) : 13600 - 13611
  • [40] Six-Degree-of-Freedom Localization With a 3-Axis Accelerometer and a 2-Axis Magnetometer for Magnetic Capsule Endoscopy
    Sperry, Adam J.
    Christensen, Jordan J.
    Abbott, Jake J.
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2022, 7 (02) : 2110 - 2115