The calibration of 3-axis magnetic sensor array system for tracking wireless capsule endoscope

被引:39
|
作者
Hu, Chao [1 ,2 ]
Meng, Max Q. -H. [3 ]
Mandal, Mrinal [2 ]
机构
[1] Ningbo Univ, Dept Elect Eng & Automat, Ningbo, Peoples R China
[2] Univ Alberta, Dept ECE, Edmonton, AB T6G 2M7, Canada
[3] Chinese Univ Hong Kong, Dept EE, Shatin, Peoples R China
关键词
calibration; magnetic localization and orientation; real time tracking; wireless capsule endoscope;
D O I
10.1109/IROS.2006.282118
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A magnetic localization and orientation system is proposed for tracking wireless capsule endoscope. This system uses a small magnet enclosed in the capsule to serve as excitation source. When the capsule moves, the magnet establishes a static magnetic field around. With the magnetic sensor array composed of Honeywell 3-axis magnetic sensors, HMC1053, the magnetic intensities in some pre-determined spatial points can be detected, and the magnet's position and orientation parameters can be computed based on an algorithm. To initiate the system and obtain better tracking accuracy, we propose a calibration technique for the magnetic tracking system. The calibration includes sensitivity determination and nonlinearity adjustment, sensor center position and orientation adjustment. Based on the calibration procedures, the system can achieve satisfactory tracking accuracy with the average localization error 3.3 mm and the average orientation error 3.0 degrees.
引用
收藏
页码:162 / +
页数:2
相关论文
共 50 条
  • [11] Magnetic Tracking of Wireless Capsule Endoscope in Mobile Setup Based on Differential Signals
    Song, Shuang
    Wang, Shuo
    Yuan, Sishen
    Wang, Jiaole
    Liu, Wei
    Meng, Max Q. -H.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [12] Designs of Slope Magnetic Flux Guides for 3-Axis Magnetic Sensor
    Zhao, Jianqiang
    Tian, Wugang
    Zhang, Qi
    Pan, Mengchun
    Hu, Jiafei
    Chen, Dixiang
    Luo, Feilu
    IEEE TRANSACTIONS ON MAGNETICS, 2013, 49 (10) : 5301 - 5303
  • [13] A Three-Axis Magnetic Sensor Array System for Permanent Magnet Tracking
    Dai, Houde
    Yang, Wanan
    Xia, Xuke
    Su, Shijian
    Ma, Kui
    2016 IEEE INTERNATIONAL CONFERENCE ON MULTISENSOR FUSION AND INTEGRATION FOR INTELLIGENT SYSTEMS (MFI), 2016, : 476 - 480
  • [14] Development of a Wireless Capsule Endoscope System Based on Field Programmable Gate Array
    李四青
    刘华
    Journal of Shanghai Jiaotong University(Science), 2017, 22 (02) : 156 - 160
  • [15] Development of a wireless capsule endoscope system based on field programmable gate array
    Li S.
    Liu H.
    Journal of Shanghai Jiaotong University (Science), 2017, 22 (02) : 156 - 160
  • [16] Localizing and tracking of medical capsule in human by magnetic sensor array
    Zheng, Xiao-Lin
    Li, Jin
    Hou, Wen-Sheng
    He, Jin
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2009, 17 (03): : 576 - 582
  • [17] Active actuation system of wireless capsule endoscope based on magnetic field
    Chen, Dongmei
    Hu, Chao
    Wang, Lei
    Meng, Max Q. -H.
    2007 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS, VOLS 1-5, 2007, : 99 - 103
  • [18] 3-Axis Static Magnetic Field Cancellation System
    Kang, Inchol
    Kim, Soochan
    2014 7TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2014,
  • [19] Wireless 3-Axis Accelerometer System for Measurement of Structural Displacement
    Gurkan, Koray
    Gurkan, Guray
    Dindar, Ahmet Anil
    Akpinar, Burak
    Gulal, Engin
    2013 8TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONICS ENGINEERING (ELECO), 2013, : 403 - 406
  • [20] Video-based measurements for wireless capsule endoscope tracking
    Spyrou, Evaggelos
    Iakovidis, Dimitris K.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2014, 25 (01)