Improving the Contrast-to-Noise Ratio by Averaging in Scintillation Detectors

被引:0
|
作者
Vopalensky, Michal [1 ]
Kumpoa, Ivana [1 ]
Vavrik, Daniel [2 ]
机构
[1] Ctr Excellence Tele, Inst Theoret & Appl Mech, Batelovska 486, Tele 58856, Czech Republic
[2] Ctr Excellence Tele, Inst Theoret & Appl Mech, Batelovska 485, Tele 58856, Czech Republic
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
From the point of view of the image quality, the contrast-to-noise ratio (CNR) is a crucial parameter. In case of the scintillation detectors, which are widely used in X-ray radiography and computed tomography, CNR is determined by the static image noise caused mainly by the non-uniformity of the response of particular pixels, and by the stochastic noise, composed of the inherent noise of the detector and the X-ray beam fluctuation. The static noise can be suppressed using appropriate correction methods, such as the flat field correction. The stochastic component of noise can be lowered by averaging of more images of the same scene, but this approach leads to an increased time of the tomography, which can be an undesirable effect. This paper shows a method that separates the stochastic noise component from the static noise component and thus allows to determine the maximum reachable CNR in the given case and the minimum number of images to he averaged for reaching required CNR. The method is intended to be used for optimized setting of the detector and X-ray source parameters in tomography to obtain the best possible results in a reasonable time.
引用
下载
收藏
页数:3
相关论文
共 50 条
  • [41] Contrast-to-noise ratio in functional MRI of relative cerebral blood volume with sprodiamide injection
    Lev, MH
    Kulke, SF
    Sorensen, AG
    Boxerman, JL
    Brady, TJ
    Rosen, BR
    Buchbinder, BR
    Weisskoff, RM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03): : 523 - 527
  • [42] A new contrast-to-noise ratio for image quality characterization of a coded-aperture γ camera
    Zhu, Balin
    Wang, Zhonghai
    Gao, Tai
    Chen, Qi
    Huang, Qichang
    Mao, Xiaoqin
    Zhao, Chaoyang
    Tao, Mingrui
    Qi, Peiwen
    Zhao, Qianru
    Li, Yulong
    Zhou, Rong
    Yang, Chaowen
    APPLIED RADIATION AND ISOTOPES, 2021, 170
  • [43] Optimal Weighting Strategies for Maximizing Contrast-to-Noise Ratio in Photon Counting CT Images
    Yang, Yirong
    Wang, Sen
    Stevens, Grant
    Fan, Jiahua
    Wang, Adam S.
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [44] Signal-to-noise ratio, contrast-to-noise ratio and their trade-offs with resolution in axial-shear strain elastography
    Thitaikumar, Arun
    Krouskop, Thomas A.
    Ophir, Jonathan
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (01): : 13 - 28
  • [45] Effects of KVp On Dose-Normalized Contrast-To-Noise Ratio Relevant to Pediatric CT
    Feng, W.
    MacDougall, R.
    Schultz, C.
    Drake, D.
    Bakalyar, D.
    MEDICAL PHYSICS, 2009, 36 (06) : 2729 - +
  • [46] The Influence of Contrast-to-Noise Ratio on the Discrimination Between Cortical and Juxtacortical Lesions in Multiple Sclerosis
    Girolamo, Crisi
    Filice, Silvano
    Graziuso, Stefania
    Francesca, Tona
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (06) : 958 - 962
  • [47] CT brain perfusion: A static phantom study of contrast-to-noise ratio and radiation dose
    Midgley, Stewart M.
    Stella, Damien L.
    Campbell, Bruce C. V.
    Langenberg, Francesca
    Einsiedel, Paul F.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2017, 61 (03) : 361 - 366
  • [48] Nonlinear stress-strain relationships in tissue and their effect on the contrast-to-noise ratio in elastograms
    Varghese, T
    Ophir, J
    Krouskop, TA
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (05): : 839 - 851
  • [49] Single Atom Detection from Low Contrast-to-Noise Ratio Electron Microscopy Images
    Fatermans, J.
    den Dekker, A. J.
    Muller-Caspary, K.
    Lobato, I.
    O'Leary, C. M.
    Nellist, P. D.
    Van Aert, S.
    PHYSICAL REVIEW LETTERS, 2018, 121 (05)
  • [50] Improvement in CT Contrast-To-Noise Ratio in Low Contrast Spherical Simulated Liver Lesions Using Iterative Reconstruction
    Dong, F.
    Herts, B.
    Baker, M.
    Goenka, A.
    Primak, A.
    MEDICAL PHYSICS, 2013, 40 (06)