Improving the Contrast-to-Noise Ratio by Averaging in Scintillation Detectors

被引:0
|
作者
Vopalensky, Michal [1 ]
Kumpoa, Ivana [1 ]
Vavrik, Daniel [2 ]
机构
[1] Ctr Excellence Tele, Inst Theoret & Appl Mech, Batelovska 486, Tele 58856, Czech Republic
[2] Ctr Excellence Tele, Inst Theoret & Appl Mech, Batelovska 485, Tele 58856, Czech Republic
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
From the point of view of the image quality, the contrast-to-noise ratio (CNR) is a crucial parameter. In case of the scintillation detectors, which are widely used in X-ray radiography and computed tomography, CNR is determined by the static image noise caused mainly by the non-uniformity of the response of particular pixels, and by the stochastic noise, composed of the inherent noise of the detector and the X-ray beam fluctuation. The static noise can be suppressed using appropriate correction methods, such as the flat field correction. The stochastic component of noise can be lowered by averaging of more images of the same scene, but this approach leads to an increased time of the tomography, which can be an undesirable effect. This paper shows a method that separates the stochastic noise component from the static noise component and thus allows to determine the maximum reachable CNR in the given case and the minimum number of images to he averaged for reaching required CNR. The method is intended to be used for optimized setting of the detector and X-ray source parameters in tomography to obtain the best possible results in a reasonable time.
引用
下载
收藏
页数:3
相关论文
共 50 条
  • [21] Validation of noise estimation for a clinical contrast-to-noise ratio for digital mammographic imaging
    Hill, Melissa L.
    Mackenzie, Alistair
    Khan, Nabeel
    Wang, Kaier
    Highnam, Ralph P.
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [22] Mammographic image quality assessment by a contrast-to-noise ratio for clinical images
    Hill, Melissa L.
    Mackenzie, Alistair
    Warren, Lucy M.
    Khan, Nabeel
    Wang, Kaier
    Highnam, Ralph P.
    15TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI2020), 2020, 11513
  • [23] Contrast-to-noise ratio optimization for a prototype phase-contrast computed tomography scanner
    Mueller, Mark
    Yaroshenko, Andre
    Velroyen, Astrid
    Bech, Martin
    Tapfer, Arne
    Pauwels, Bart
    Bruyndonckx, Peter
    Sasov, Alexander
    Pfeiffer, Franz
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (12):
  • [24] Blind Estimation for Localized Low Contrast-to-Noise Ratio BOLD Signals
    Atkinson, Ian C.
    Kamalabadi, Farzad
    Jones, Douglas L.
    Thulborn, Keith R.
    IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, 2008, 2 (06) : 879 - 890
  • [25] Application of the generalized contrast-to-noise ratio to assess photoacoustic image quality
    Kempski, Kelley M.
    Graham, Michelle T.
    Gubbi, Mardava R.
    Palmer, Theron
    Bell, Muyinatu A. Lediju
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (07) : 3684 - 3698
  • [26] The Contrast-to-Noise Ratio for Image Quality Evaluation in Scanning Electron Microscopy
    Timischl, F.
    SCANNING, 2015, 37 (01) : 54 - 62
  • [27] Signal-to-noise ratio, contrast-to-noise ratio, and exposure time for imaging systems with photon-limited noise
    Lucke, Robert L.
    Kessel, Robert A.
    OPTICAL ENGINEERING, 2006, 45 (05)
  • [28] Signal-to-noise ratio, contrast-to-noise ratio and pharmacokinetic modeling considerations in dynamic contrast-enhanced magnetic resonance imaging
    Li, Xin
    Huang, Wei
    Rooney, William D.
    MAGNETIC RESONANCE IMAGING, 2012, 30 (09) : 1313 - 1322
  • [29] Effect of kVp on Noise, Dose, and Contrast-to-Noise Ratio for Pediatric Low-Dose CT
    Gamberoni, J.
    Dong, F.
    Davros, B.
    Reid, J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [30] Improvements in elastographic contrast-to-noise ratio using spatial-angular compounding
    Techavipoo, U
    Varghese, T
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (04): : 529 - 536