Improving the Contrast-to-Noise Ratio by Averaging in Scintillation Detectors

被引:0
|
作者
Vopalensky, Michal [1 ]
Kumpoa, Ivana [1 ]
Vavrik, Daniel [2 ]
机构
[1] Ctr Excellence Tele, Inst Theoret & Appl Mech, Batelovska 486, Tele 58856, Czech Republic
[2] Ctr Excellence Tele, Inst Theoret & Appl Mech, Batelovska 485, Tele 58856, Czech Republic
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
From the point of view of the image quality, the contrast-to-noise ratio (CNR) is a crucial parameter. In case of the scintillation detectors, which are widely used in X-ray radiography and computed tomography, CNR is determined by the static image noise caused mainly by the non-uniformity of the response of particular pixels, and by the stochastic noise, composed of the inherent noise of the detector and the X-ray beam fluctuation. The static noise can be suppressed using appropriate correction methods, such as the flat field correction. The stochastic component of noise can be lowered by averaging of more images of the same scene, but this approach leads to an increased time of the tomography, which can be an undesirable effect. This paper shows a method that separates the stochastic noise component from the static noise component and thus allows to determine the maximum reachable CNR in the given case and the minimum number of images to he averaged for reaching required CNR. The method is intended to be used for optimized setting of the detector and X-ray source parameters in tomography to obtain the best possible results in a reasonable time.
引用
下载
收藏
页数:3
相关论文
共 50 条
  • [1] The Generalized Contrast-to-Noise Ratio
    Rodriguez-Molares, Alfonso
    Rindal, Ole Marius Hoel
    D'hooge, Jan
    Masoy, Svein-Erik
    Austeng, Andreas
    Torp, Hans
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [2] Temporal averaging introduced in linear regression beamforming for improvement of contrast-to-noise ratio
    Hasegawa, Hideyuki
    Nagaoka, Ryo
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2020, 59 (59)
  • [3] A novel method for contrast-to-noise ratio (CNR) evaluation of digital mammography detectors
    Baldelli, P.
    Phelan, N.
    Egan, G.
    EUROPEAN RADIOLOGY, 2009, 19 (09) : 2275 - 2285
  • [4] A novel method for contrast-to-noise ratio (CNR) evaluation of digital mammography detectors
    P. Baldelli
    N. Phelan
    G. Egan
    European Radiology, 2009, 19 : 2275 - 2285
  • [5] An analysis of elastographic contrast-to-noise ratio
    Varghese, T
    Ophir, J
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (06): : 915 - 924
  • [6] On the Definition of Signal-To-Noise Ratio and Contrast-To-Noise Ratio for fMRI Data
    Welvaert, Marijke
    Rosseel, Yves
    PLOS ONE, 2013, 8 (11):
  • [7] Methods for Enhancing the Robustness of the Generalized Contrast-to-Noise Ratio
    Schlunk, Siegfried
    Byram, Brett C.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2023, 70 (08) : 831 - 842
  • [8] Contrast-to-noise ratio (CNR) as a quality parameter in fMRI
    Geissler, Alexander
    Gartus, Andreas
    Foki, Thomas
    Tahamtan, Amir Reza
    Beisteiner, Roland
    Barth, Markus
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (06) : 1263 - 1270
  • [9] The Contrast-To-Noise Ratio Optimized Fluoroscopy Operation Logic
    Lin, P.
    Goode, A.
    Corwin, F.
    MEDICAL PHYSICS, 2020, 47 (06) : E556 - E556
  • [10] Measurement of contrast-to-noise ratio for differential phase contrast computed tomography
    Zambelli, Joseph
    Bevins, Nicholas
    Qi, Zhihua
    Chen, Guang-Hong
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622