Vanillylmandelic and Homovanillic acid: Electroanalysis at non-modified and polymer-modified carbon-based electrodes

被引:38
|
作者
Baluchova, Simona [1 ]
Barek, Jiri [1 ]
Tome, Luciana I. N. [2 ]
Brett, Christopher M. A. [2 ]
Schwarzova-Peckova, Karolina [1 ]
机构
[1] Charles Univ Prague, Dept Analyt Chem, Fac Sci, UNESCO Lab Environm Electrochem, Albertov 6, Prague 12843 2, Czech Republic
[2] Univ Coimbra, Fac Sci & Technol, Dept Chem, Rua Larga, P-3004535 Coimbra, Portugal
关键词
Homovanillic acid; Vanillylmandelic acid; Boron-doped diamond; Modified glassy carbon electrode; Voltammetry; BORON-DOPED DIAMOND; HUMAN URINE SAMPLES; PERFORMANCE LIQUID-CHROMATOGRAPHY; COMPETITIVE ENZYME-IMMUNOASSAY; NEUROENDOCRINE TUMOR-MARKERS; CAPILLARY-ELECTROPHORESIS; CATECHOLAMINE METABOLITES; AMPEROMETRIC DETECTION; MASS-SPECTROMETRY; ASCORBIC-ACID;
D O I
10.1016/j.jelechem.2018.03.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical behaviour of two main catecholamine metabolites serving as diagnostic tumour biomarkers, homovanillic acid (HVA) and vanillylmandelic acid (VMA), on anodically oxidized boron doped diamond (BDD) electrodes, non-modified glassy carbon electrodes (GCE), and GCE modified by polymers, namely by Nafion (Nafion/GCE) and by poly(neutral red) (PNR/GCE), was investigated. The voltammetric responses of both biomarkers are strongly dependent on pH of the aqueous buffer solution and electrode material used. BDD electrodes exhibit more positive oxidation potentials and lower current densities for oxidation of both analytes, depending also on the surface termination. Concentration dependences were measured in 0.1 mol L-1 phosphate buffer pH 3.0, as optimal supporting electrolyte for differential pulse voltammetric determination. Achieved detection limits were 0.6, 0.9, 0.8, and 1.2 mu mol L-1 for HVA and 0.4, 1.5, 2.4, and 1.1 mu mol L-1 for VMA at BDD electrodes, non-modified GCE, Nafion/GCE, and PNR/GCE, respectively. The limits of quantification for both organic compounds on all tested electrode materials are sufficiently low for their determination in urine. Verification of the possibility of simultaneous voltammetric determination of the studied biomarkers in the mixture was also carried out.
引用
收藏
页码:22 / 32
页数:11
相关论文
共 50 条
  • [41] Strategies, development and applications of polymer-modified electrodes for stripping analysis
    Gouveia-Caridade, Carla
    Brett, Christopher M. A.
    CURRENT ANALYTICAL CHEMISTRY, 2008, 4 (03) : 206 - 214
  • [42] GAMMA-IRRADIATED POLYMER-MODIFIED MERCURY FILM ELECTRODES
    KELLY, MJ
    HEINEMAN, WR
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 222 (1-2): : 243 - 256
  • [43] Preparation of Thermoresponsive Polymer-Modified Electrodes Having a TEMPO Moiety
    Uemukai, Toru
    Hioki, Tomoya
    Ishifune, Manabu
    ELECTROCHEMISTRY, 2013, 81 (05) : 383 - 387
  • [44] POLYMER-MODIFIED ELECTRODES, CATALYSIS AND WATER-SPLITTING REACTIONS
    FRANK, AJ
    HONDA, K
    JOURNAL OF PHOTOCHEMISTRY, 1985, 29 (1-2): : 195 - 204
  • [45] Dispersing Behavior of Non-Modified and Functionalized Carbon Nanotubes
    Dresel, Alexander
    Teipel, Ulrich
    CHEMIE INGENIEUR TECHNIK, 2012, 84 (03) : 382 - 387
  • [46] REDOX POLYMER-MODIFIED ELECTRODES FOR THE ELECTROCATALYTIC REGENERATION OF NAD+
    HALE, PD
    LEE, HS
    OKAMOTO, Y
    ANALYTICAL LETTERS, 1993, 26 (06) : 1073 - 1085
  • [47] CHRONOAMPEROMETRY OF POLYMER-MODIFIED ELECTRODES CHARGE TRANSPORT BY DIFFUSION AND MIGRATION
    YAP, WT
    DURST, RA
    BLUBAUGH, EA
    BLUBAUGH, DD
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1983, 144 (1-2) : 69 - 75
  • [48] Chemically Modified Carbon-based Electrodes for the Detection of Paracetamol: A Short Review
    Mou, Abdelaziz Ait Sidi
    Daoudi, Mohammed
    Ghanjaoui, Mohammed El Amine
    El Gamany, Bouchaib
    El Mchaouri, Abdellah
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2021, 13 (03): : 305 - 318
  • [49] Bismuth Modified Carbon-Based Electrodes for the Determination of Selected Neonicotinoid Insecticides
    Guzsvany, Valeria
    Papp, Zsigmond
    Zbiljic, Jasmina
    Vajdle, Olga
    Rodic, Marko
    MOLECULES, 2011, 16 (06): : 4451 - 4466
  • [50] Microporous Polymer-Modified Glassy Carbon Electrodes for the Electrochemical Detection of Metronidazole: Experimental and Theoretical Insights
    Quiroz-Arturo, Hector
    Reinoso, Carlos
    Scherf, Ullrich
    Palma-Cando, Alex
    NANOMATERIALS, 2024, 14 (02)